Page 70
VILLAGER 2+2 LSV ELECTRIC
Operators Manual
TPCC01VS00EN017 (Edition A)
3.
Disconnect the positive (+) cable (2).
Note:
Wait 90 seconds for the controller capacitors to discharge.
CONNECT THE BATTERIES
DANGER
BATTERIES DISCONNECTED OR CONNECTED WITH THE RUN/
TOW SWITCH SET TO RUN CAN CAUSE A BATTERY EXPLOSION
AND SERIOUS PERSONAL INJURY. SET THE RUN/TOW SWITCH
TO TOW BEFORE THE BATTERIES ARE DISCONNECTED OR
CONNECTED.
1.
Set the Run/Tow switch to TOW.
2.
Connect the positive (+) cable (2).
3.
Connect the negative (-) cable (1).
4.
Tighten the hardware to 110 lb·in (12.4 N·m).
5.
Apply battery terminal protector spray to the battery terminals.
6.
Set the Run/Tow switch to RUN.