ELECTRICAL SYSTEM AND TESTING
Troubleshooting
2008-2011 IQ Plus Electric Vehicle Maintenance and Service Supplement
Page 11-19
11
3. If reading is zero volts, check the purple/white wire continuity from the three-pin connector at the MCOR
to the 24-pin connector at the speed controller. Check terminal positions in three-pin connector at the
MCOR and the 24-pin connector. If all of the continuity readings are correct and the connectors are wired
correctly, replace the speed controller.
4. With multimeter set to 20 volts DC, place the black (–) probe on battery no. 8 negative post and the red
(+) probe (with insulation-piercing probe) on the white wire (2) at a point close to the three-pin connector
at the MCOR
. The reading should be approximately 4.65 volts.
5. If reading is zero volts, check the white wire continuity from the three-pin connector at the MCOR to the
24-pin connector at the speed controller. Check terminal positions in three-pin connector at the MCOR
and the 24-pin connector. If all of the continuity readings are correct and the connectors are wired cor-
rectly, replace the speed controller.
6. With multimeter set to 20 volts DC, place the black (–) probe on battery no. 8 negative post and the red
(+) probe (with insulation-piercing probe) on the yellow wire (3) at a point close to three-pin connector at
the MCOR
. The reading should be approximately 0.32 volts with the pedal up. Slowly
press the accelerator pedal and note the readings on the multimeter. As the pedal is pressed, the reading
should increase until it reaches 4.65 volts when the pedal is fully pressed.
7. If reading does not increase as the pedal is pressed, replace the MCOR.
8. If the reading is not approximately 4.60 volts with the pedal fully pressed, the vehicle will not operate at
rated top speed. Check the MCOR resistance.
8.1. Disconnect the batteries and discharge the controller.
See Disconnecting The Batteries on
Figure 11-12 Test MCOR: White Wire (+)
Figure 11-13 Test MCOR: Yellow Wire (+)
Passenger Side Frame Rail
3