Architect’s and Engineer’s Specification

An optional remote module shall be available for the Cloud Z4

MK4

/

Z8

MK4 

and

 

Z4

MK3

/Z8

MK3

 Zone Mixers. It shall also be compatible 

with the Cloud 46-120 and 46-120

MEDIA

 Zone Mixing Amplifiers. The 

module shall be provided with OUTPUT and LINK RJ45 connectors to 

permit connection to the host unit and other similar input modules via 
screened Category 5 data cable.

The remote module shall allow the connection of i) a balanced 
microphone via a 3-pin XLR connector and ii) a stereo unbalanced 
audio  source  on  both  phono  (RCA)  connectors  and  a  3.5  mm  dia. 
3-pole  jack. All  connectors  shall  be  accessible  from  the  front  of  the 

module. The microphone input shall have a gain control with a range 

of sufficient magnitude to allow dynamic microphones of any type to 
be used effectively. The stereo music input shall have a separate level 

control; the phono inputs shall be capable of accepting signals with a 
nominal level of 0 dBu, and the jack input signals with a nominal level 
of +8 dBu. The stereo channels shall be summed into mono and mixed 

with the microphone signal within the module.

A user-switchable priority facility will be provided to reduce the level 
of both the music signal connected at the module and the music source 
selected at the host unit for that Zone by 30 dB. It shall be possible to 
modify the priority operation by internal jumpers so that the sum of 
the microphone and music inputs mute the music source selected at the 
host unit for that Zone.

Circuitry shall be included such that interconnected modules which do 

not have microphones connected do not contribute any perceptible 

noise to the output signal.

The module shall also incorporate remote controls of the rotary type 
providing  selection  of  i)  music  source  and  ii)  music  level,  within  the 

host unit. It shall be possible to disable either of these functions on a 

module when multiple modules are interconnected, so that only one 
linked module in a Zone has control of the host unit.

The remote module shall be available in versions suitable for fitment in 

standard UK, US or German electrical back boxes. The modules shall be 

available in a choice of finishes.

The remote modules shall be the Cloud LM-2W (UK version, white 
finish), the Cloud LM-2B (UK version, black finish), the Cloud LM-2AW 
(US version, white finish), the Cloud LM-2AB (US version, black finish), 

the  Cloud  LM-2DW  (German  version,  white  finish)  and  the  Cloud     
LM-2DB (German version, black finish).