Installing transformers without 

CXL Series rackmount housings

Where appropriate, CXL Series transformers may be 
installed in various ways without the use of CXL-800 

or CXL-1600 rackmount housings. However, it is important 
to appreciate that correct use of the rackmount housings 
provides good safety protection from the high voltages 

involved (see “Important Safety Notes” on page 2).  
If fitting the transformers without rackmount housings, 
careful attention must be paid to the safety aspects of the 
installation, to prevent the risk of electric shocks.
A transformer may be mounted horizontally or vertically 
onto any convenient clear, flat surface with the single M6 
fixing bolt through the toroid’s centre hole. Mounting it 
immediately adjacent to the amplifier is not mandatory, 
though may often be the most practical solution. 
Consideration should be given to ventilation, particularly 
if multiple transformers are housed together and/or 
the amplifier has a high duty cycle (i.e., handling audio 
continuously).
Refer to “Fitting the connectors” on page 6. The 
transformer’s windings are terminated in a 2-pin (primary) 
and a 3-pin (secondary) 5 mm–pitch female screw-
terminal connector mounted on a PCB. When mounting a 
transformer without a rack tray, the connector assembly 
should be removed by cutting it off. Connection to the 
amplifier’s low-impedance output and to the loudspeaker 
system can be made using insulated terminal blocks (see 
Safety Notes below). 
Take care to observe the wire colour coding: 

100 V  SYSTEMS

Connection

Colour

Primary

From amplifier’s lo-Z 

output

+

Red

-

Black

Secondary

To 100 V-line loudspeak-

er system

+

White

-

Blue

70 V  SYSTEMS

Connection

Colour

Primary

From amplifier’s lo-Z 

output

+

Red

-

Black

Secondary

To 70 V-line loudspeaker 

system

+

Purple

-

Blue

Use wire of the correct gauge for the transformer/amplifier 
power rating; this applies to both primary and secondary 
connections. The minimum wire gauges to be used are given 
in the following table:

TYPE

CONNECTION

MIN. WIRE 

GAUGE

CXL-40T

Primary (input)

1.5 mm

2

Secondary (output)

0.75 mm

2

CXL-100T

Primary (input)

1.5 mm

2

Secondary (output)

0.75 mm

2

CXL-200T

Primary (input)

1.5 mm

2

Secondary (output)

1 mm

2

CXL-400T

Primary (input)

1.5 mm

2

Secondary (output)

1 mm

2

The wiring should make use of insulated terminal blocks and 
fully-shrouded crimp terminals. Where possible, secure the 
terminal blocks to the panel on which the transformers are 
mounted with screws or nuts and bolts as appropriate. Keep 
the transformers’ leads neat with cable ties and sticky-back 

bases.





















If transformers are being freely-mounted on a panel within 
an equipment rack, fit lockable side and rear doors, and 
blank 19” panels as necessary to the rack, to prevent access 
to the terminations. If the transformers are to be housed 
externally to a rack, the use of a lockable IP-rated enclosure 
fitted with the appropriate cable grommets is recommended.

Summary of Contents for CXL-100T

Page 1: ...CXL Manual v1 0 1 CXL 40T CXL 100T CXL 200T CXL 400T 100 70VTransformers CXL 800 CXL 1600 Rackmount Housings Installation Guide...

Page 2: ...signed CXL Series rackmount housings or by mounting and wiring the transformers in such a way that neither the transformers nor their connections can be touched accidently In all cases transformers an...

Page 3: ...4 Transformer Amplifier compatibility 5 Transformer Rackmount Housing compatibility 5 Installing transformers in the CXL 800 rackmount housing 6 Installing transformers in the CXL 1600 rackmount hous...

Page 4: ...hese housings are used in conjunction with the transformers as the complete assembly provides good safety protection Scope of this manual The primary purpose of this manual is to describe how to mecha...

Page 5: ...ty CXL 800 The CXL 800 is of open construction and is designed to accommodate up to eight CXL 40T or CXL 100T transformers including any mixture of the two types It is not suitable for CXL 200T or CXL...

Page 6: ...panel connector positions Each transformer has five colour coded wires which terminate on a small PCB A 2 way and a 3 way 5 mm pitch female connector and two M3 fixing brackets are fitted to the PCB L...

Page 7: ...g rotate the toroids to ensure that the cable assemblies for all the transformers emerge from the windings at a neat orientation for wiring to the rear panel If the CXL 1600 is being fitted with less...

Page 8: ...mplifier Outputs The transformer outputs may be connected to the loudspeaker system Use the mating 3 pin 5 mm pitch screw terminal connectors supplied with the transformers and two core stranded cable...

Page 9: ...fier s low impedance output and to the loudspeaker system can be made using insulated terminal blocks see Safety Notes below Take care to observe the wire colour coding 100V SYSTEMS Connection Colour...

Page 10: ...CXL Manual v1 0 10...

Page 11: ...CXL Manual v1 0 11...

Page 12: ...Cloud Electronics Limited 140 Staniforth Road Sheffield S9 3HF England Tel 44 0 114 244 7051 Fax 44 0 114 242 5462 email info cloud co uk web www cloud co uk...

Reviews: