Installing transformers in the 

CXL-1600 rackmount housing

The CXL-1600 is a fully enclosed steel 19” rackmount 
housing; it has a depth of 225 mm, but a minimum rack depth 
of 250 mm is recommended to allow adequate clearance for 
rear connectors and cables.
Up to four CXL-200T or CXL-400T transformers may be 
installed in a CXL-1600. Any mixture of the two types may 
also be fitted, up to a total of four transformers. The  
CXL-1600 will also accept up to CXL-40T and/or  
CXL-100T transformers, in the same manner as the  
CXL-800. Mixtures of all transformer types are permissible, 
up to the maximum limits specified in the table in 
“Transformer/Rackmount Housing compatibility” on page 5
Remove the top cover of the housing and retain the screws.
Each transformer is fitted to the chassis baseplate with 
a single M6 bolt (one supplied with each transformer). 
Identify the twelve pre-drilled 6 mm holes in the baseplate. 

If fitting a mixture of transformer types, note that certain 
constraints exist as to transformer positioning, due to the 
larger diameter of the higher-powered transformers. See 
the template supplied with the housing, which illustrates the 
locating options. Note that when fitting four CXL-200T and/
or CXL-400T transformers, only the four odd-numbered 
positions are available as combinations. Specific baseplate 
holes are provided to cater for these transformer types.

When each transformer position has been determined, 
insert the bolt from the underside of the chassis, place 
the transformer in position with the bolt through the 
central hole, and secure it in place with the washer 
and locknut supplied. Before final tightening, rotate 
the toroids to ensure that the cable assemblies 
for all the transformers emerge from the windings 
at a neat orientation for wiring to the rear panel.

If the CXL-1600 is being fitted with less than its full 
complement of transformers, any positions may be used 
as convenient, provided the spacing constraints of mixed 
transformer sizes are observed.

Fitting the connectors

Note that each of the transformer positions is aligned with 
one of the rear panel connector positions.

































Each transformer has five colour-coded wires which 

terminate on a small PCB. A 2-way and a 3-way 5 mm-pitch 
female connector, and two M3 fixing brackets are fitted to 
the PCB. Locate the connectors into the rectangular rear 
panel slot which is in line with the transformer’s position. 
Note that, looking at the rear panel, the 3-way connector 
goes to the left of the slot.
Secure each PCB/connector assembly in place with EITHER 
two M3 x 6 mm Pozi screws, OR one M3 x 6 mm Pozi screw 
and one M3 x 25 mm hex pillar. The screws and/or pillars 
should be passed through the fixing holes and tightened into 
the tapped holes in the fixing brackets. Which of the two 
fixing options is used depends on the connector (from 1 to 
8) being fitted. The diagram below shows a rear panel with 
all eight connectors fitted; the arrows indicate the correct 
locations for the hex pillars.

See diagram on page 6 for details of connector 
mountings
IMPORTANT: If less than eight transformers are installed in 
the rackmount housing, it is still important to fit all six hex 
pillars (supplied) in the positions indicated. If a connector 
position requiring a hex pillar is empty (due there being no 
transformer in that position), use an M3 shakeproof washer 
and nut (supplied) to secure the hex pillar in place.

Re-assembling the housing

Replace the lid of the housing and secure using the original 
screws.

Summary of Contents for CXL-100T

Page 1: ...CXL Manual v1 0 1 CXL 40T CXL 100T CXL 200T CXL 400T 100 70VTransformers CXL 800 CXL 1600 Rackmount Housings Installation Guide...

Page 2: ...signed CXL Series rackmount housings or by mounting and wiring the transformers in such a way that neither the transformers nor their connections can be touched accidently In all cases transformers an...

Page 3: ...4 Transformer Amplifier compatibility 5 Transformer Rackmount Housing compatibility 5 Installing transformers in the CXL 800 rackmount housing 6 Installing transformers in the CXL 1600 rackmount hous...

Page 4: ...hese housings are used in conjunction with the transformers as the complete assembly provides good safety protection Scope of this manual The primary purpose of this manual is to describe how to mecha...

Page 5: ...ty CXL 800 The CXL 800 is of open construction and is designed to accommodate up to eight CXL 40T or CXL 100T transformers including any mixture of the two types It is not suitable for CXL 200T or CXL...

Page 6: ...panel connector positions Each transformer has five colour coded wires which terminate on a small PCB A 2 way and a 3 way 5 mm pitch female connector and two M3 fixing brackets are fitted to the PCB L...

Page 7: ...g rotate the toroids to ensure that the cable assemblies for all the transformers emerge from the windings at a neat orientation for wiring to the rear panel If the CXL 1600 is being fitted with less...

Page 8: ...mplifier Outputs The transformer outputs may be connected to the loudspeaker system Use the mating 3 pin 5 mm pitch screw terminal connectors supplied with the transformers and two core stranded cable...

Page 9: ...fier s low impedance output and to the loudspeaker system can be made using insulated terminal blocks see Safety Notes below Take care to observe the wire colour coding 100V SYSTEMS Connection Colour...

Page 10: ...CXL Manual v1 0 10...

Page 11: ...CXL Manual v1 0 11...

Page 12: ...Cloud Electronics Limited 140 Staniforth Road Sheffield S9 3HF England Tel 44 0 114 244 7051 Fax 44 0 114 242 5462 email info cloud co uk web www cloud co uk...

Reviews: