CX263 Installation and User Guide v1.1
11
Before the RL-1 will operate, the zone’s
REMOTE
port must
be enabled by setting the adjacent
FR/REM
push-button
switch ([9] on “Description of rear panel” on page 8
)
to REM (i.e., pressing it in). In this setting, the zone’s front
panel
MUSIC LEVEL
and
SOURCE
controls become
inoperative. As music source selection will still be required
from the mixer’s front panel when an RL-1 is in use, the REM
setting may be overridden
for the source selection control only
by moving internal jumper J20 (Zone 1), J22 (Zone 2) or
J24 (Zone 3) on the internal rear sub-board. See
“PCB jumper
location and settings” on page 19 for location of internal
jumpers.
Connecting an RSL-6 Series remote control plate
Wire the remote control plate as shown below. Twin-and-
screen cable should be used. Maximum reliable cable run is
100 m.
1 2 3
REMOTE SOURCE & LEVEL CONTROL WIRING
RSL-6
USE TWO-CORE SCREENED CABLE
1 2 3
REMOTE
PORT
Before the RSL-6 will operate, the zone’s
REMOTE
port must be enabled by setting the adjacent
FR/REM
push-button switch ([9] on “Description of rear panel” on
page 8
) to REM (i.e., pressing it in). In this setting, the
zone’s front panel
MUSIC LEVEL
and
SOURCE
controls
become inoperative.
Music Mute
External muting of music is available at the
MUSIC MUTE
connector. National or Local Authority regulations governing
such systems may require that normal programme material
(i.e., music) should be muted in an emergency, to ensure that
any emergency messages are clearly audible.
The Music Mute input is on a 2-pin 5 mm-pitch screw-terminal
connector. It should be connected to the appropriate alarm
output on whichever building management system registers
the alarm (typically the Fire System). The alarm output must
be volt-free; if no such output is available, an intermediate
relay or other isolation device must be installed between the
alarm output and the Music Mute input.
The Mute input can be set to operate on either normally
open (N/O) or normally closed (N/C) contacts via an internal
jumper (see “PCB jumper location and settings” on page
19
). The factory default setting is N/O, thus requiring a
short-circuit to be applied across the two pins of the
connector for muting to occur.
Visual indication of muting being activated is given by the
MUSIC MUTE
LED on the front panel.
1
2
MUSIC MUTE
INPUT
RELAY
NORMALLY OPEN (N/O)
CONNECTION
1
2
MUSIC MUTE
INPUT
RELAY
NORMALLY CLOSED (N/C)
CONNECTION