GENERAL WARNINGS

MANUAL PURPOSE 

This manual has been designed to enable the unit to be 
installed, started up and maintained correctly. 

MANUAL INSTRUCTIONS 

It is essential to observe these instructions. 
The manufacturer declines all liability for any damage that 
may be caused whether directly or indirectly to persons or 
things if these instructions are not heeded. 

MANUAL STORAGE 

This manual and the unit’s wiring diagram should be 
carefully stored so that they are readily available to the 
operator when required. 

EXPERT PERSONAL 

The unit must be installed, tested and maintained by expert 
personal who meet the relevant legal requirements (Italian 
law No. 46 of 5/3/1990). 

LOCAL SAFET REGULATION INSTALLATION  

The installation must be performed observing the local 
safety regulations. 

POWER SUPPLY 

Make sure the power supply conforms to the data on the 
unit’s rating plate, located inside the door of the main 
electrical panel. 

PACKAGING 

The packaging material (plastic bags, polystyrene foam, 
nails, etc.) is potentially dangerous and should therefore be 
kept away from children and recycled in compliance with 
the local regulations in force. 

MAINTENANCE 

Before performing any service operations, cut off the power. 
Perform the operations in conformity with the local 
regulations in force. 

PERIODICAL INSPECTIONS  

Perform periodical inspections to locate possible loosened 
or broken parts. If the repairs are not performed, there will 
be a higher risk for things and peoples to become damaged 
and injured.  

FAULT – POOR OPERATION 

Switch off the unit in the event of faults or poor operation. 

REPAIR  

Only have repairs carried out by a service centre authorised 
by the manufacturer, and insist on the use of original spare 
parts only. 
Failure to comply with the above may compromise the 
safety of the unit. 

MODIFICATIONS 

The manufacturer will not accept any responsibility, and the 
warranty will lapse, in the event of electric and/or 
mechanical modifications. Any modification which is not 
formally authorized, and which does not respect the 
instructions given in this manual, will cause the warranty to 
lapse. 

INTENDED USE 

The unit must only be used for the specific purpose it was 
designed :  

The unit is designed for civil air-conditioning within the 
limits defined in the technical bulletin and this manual. 

Any use other than that specified does not imply any 
commitment or constraint by the manufacturer in any way 
whatsoever. 

ADDITIONAL SAFETY PRECAUTIONS 

This unit has been especially designed and manufactured 
so to prevent any risk to persons and health hazard. 
For this reason, design solutions fit to eliminate (where 
possible) any cause of risk and sensibly reduce the 
probability of danger have been adopted. 
Please refer to the "Residual Risks" section of this manual 
and strictly observe the behaviour prescriptions listed there 
in order to prevent any possible risk that hasn’t been 
possible to avoid in the design stage. 

DATA UPDATING 

The manufacturer may be able to modify the data without 
prior notice as a consequence of constant improvements.  

REGULATIONS AND 
CERTIFICATIONS

 

UNI EN ISO 9001 CERTIFICATION 

Clivet S.p.A., in order to guarantee customer satisfaction, 
has chosen the ISO 9001 Quality System as the reference 
for all its business activities. This is demonstrated by the 
company’s commitment to ongoing improvements in the 
quality and reliability of its products; its sales, design, 
purchasing, production and after-sales service activities are 
the means used to reach such purpose. 

 

CE MARK

 

 

 

 

Clivet products bear the CE mark, in compliance with the 
requirements of the following EC directives, including the 
latest amendments, and with the corresponding national 
approximated legislation: 

 

- 98/37/CE 

 

- 89/336/CEE as modified by the directives 92/31/CEE 
and 93/68/CEE 

 

- 73/23/CEE as modified by the directive 93/68/CEE 

 

- 97/23/CE 

 

 

Summary of Contents for CF-V 101

Page 1: ...CF V 31 41 51 71 91 101 121 142 182 202 242 VERTICAL WATER DUCTABLE TERMINAL UNIT WITH DECORATIVE CABINET M23740N6 03 01 10 07...

Page 2: ......

Page 3: ...ATED AIR 12 E L E C T R I C A L C O N N E C T I O N 1 3 GENERAL 13 STANDARD UNIT ELECTRICAL DATA 13 CONNECTION TO THE MAINS 13 S T A R T U P 1 7 PRELIMINARY CHECKS 17 AERAULIC SYSTEM 17 WATER SYSTEM 1...

Page 4: ...nd the serial number Write them in the space below so that they are readily available when needed Type of unit _________________________________ Serial number _________________________________ Wiring...

Page 5: ...ICATIONS The manufacturer will not accept any responsibility and the warranty will lapse in the event of electric and or mechanical modifications Any modification which is not formally authorized and...

Page 6: ...orized entry GENERAL RISKS A smell of burning smoke or other indications of serious irregularity could signal the onset of situations liable to cause damage to persons or property or to the unit itsel...

Page 7: ...n the isolating switch on the power line to the unit is set to the OFF position and padlocked and post a warning sign Before removing the protective grilles or the fans themselves make certain the iso...

Page 8: ...s in force Legislative Decree 626 94 and following modifications Before starting the handling operations Value the critical points during handling stairs flights disconnected routes doors etc Verify t...

Page 9: ...responsible for evaluating the opportunity of installing drain tubes in conformity with the local regulations in force EN 378 3 Install the unit raised from the ground 4 avoid installations in places...

Page 10: ...connections are subject to temperatures near 0 C mix the water of the system with glycol protect the tubes with heating cables under the tubes insulation empty the system by verifying that o no taps...

Page 11: ...is unused for a long period TO AVOID THE FREEZE FORMING INSIDE THE COIL 1 If the unit or the relevant water connection are subjects to temperatures next to 0 C see RISK OF FREEZE in the GENERAL WARNI...

Page 12: ...es with a wide radius Consider whether it might be useful to equip them with deflectors especially if the air speed is high or if curves are tight FEATURES FOR DUCTS FOR TREATED AIR 1 The inner surfac...

Page 13: ...al Lay the cables far from power cables or cables having a different tension and that are able to emit electromagnetic disturbances Do not lay the cable near devices which can generate electromagnetic...

Page 14: ...peed By acting on trimmer TR1 anticlockwise the control power of the motor and consequently the flow rate of the unit are reduced 1 4 turn is equal to approximately 40 AC By acting on the trimmer cloc...

Page 15: ...ssed room control is supplied with a series of supports that make it possible to adapt it to the main civil series of plates refer to the instructions provided with the thermostat POSITIONING OF THE R...

Page 16: ...functionality On request Clivet provides the specifications for the communication protocol of its units and the necessary guidelines to connect them to RS485 The card for RS485 serial line must be con...

Page 17: ...deactivation When using antifreeze solutions make sure the glycol percentage is suitable for the type of use envisaged weight of ethylene glycol 10 20 30 40 Freezing point 4 C 9 C 15 C 23 C Safety tem...

Page 18: ...lles diffusers etc Pa L sec 1 2 3 B A C D D unit head flow rate curve A system calculated curve 1 project theorical working point 3 if the system has pressure drop lower than the project ones the work...

Page 19: ...mode using the relevant keys Set the P31 parameter 0 ECO Economic operation it prefers saving energy more than comfort in cooling mode the setECO is higher than the standard set in heating mode it is...

Page 20: ...visible with unit in COOLING 21 0 REMOTE ECO AUTO E c o S w i n g visible if the cooling heating choice is AUTOMATIC switch the thermostat on press and hold the ON OFF key for 4 seconds If the functi...

Page 21: ...y cooling heating If AUTO is displayed the switch from one mode to another is managed automatically from the unit and if this key is pressed no change occurs If the function is managed remotely via Mo...

Page 22: ...level sensor alarm CO Mode change in progress for the automatic mode is not an alarm EHH Lack of communication wrong thermostat connection SYS Fault internal to the control module ERR Configuration er...

Page 23: ...Fan status at cooling thermoregulator satisfied 0 stop 1 continuous 2 periodical 0 2 num 2 P22 FanOffHeat Fan status at heating thermoregulator satisfied 0 stop 1 continuous 2 periodical 0 2 num 0 P31...

Page 24: ...idity in the room where it is installed it is possible to use only the 4 front keys user programming Nolink operation HID TI not connected to CLIVET BUS the thermostat is powered by auxiliary power a...

Page 25: ...normal operation will resume preserving any modifications that have been made When setting fan speed you will go from AUTOMATIC where the speed of the fans is controlled automatically based on ambien...

Page 26: ...n problems between the device and the adjustment unit ADVANCED PROGRAMMING Hidden buttons for use by installer accessible by extracting the thermostat from its housing 5 6 not used keys accessible onl...

Page 27: ...ro Set point T amb C ON OFF p01 BandaLavoro Set point 3 speed Sizes 31 71 3 V 2 V 1 V p01 BandaLavoro Set point 3 V 2 V 1 V p01 BandaLavoro Set point WATER VALVE The system can control 2 ON OFF valves...

Page 28: ...ature alarm is not managed SINGLE PHASE RESISTANCES P01 Set Point ON OFF TWO PHASE RESISTANCES P01 Set Point DEHUMIDIFICATION The dehumidification control is managed by the network which is an upwards...

Page 29: ...r treatment coil to be able to offer maximum thermal exchange Therefore the unit must always operate with the filters installed and clean Cleaning and replacement of filters are very important in term...

Page 30: ...er The belt is tensioned correctly when the tolerances defined in the enclosed sketch are respected The tension of the belt should be checked after around 10 hours of operation Avoid the following sit...

Page 31: ...as well Refer to local actuation norms In Italy refer to the Ministerial Decree of 1 st December 2004 no 329 and following modifications which defines the performances to be executed the units of 1 st...

Page 32: ...CARRIED OUT BY AUTHORIZED SERVICE CENTERS BEFORE RESETTING AN ALARM IDENTIFY AND ELIMINATE ITS CAUSE REPEATED RESETS MAY CAUSE SERIOUS DAMAGES In certain machine configurations some safeties may be p...

Page 33: ...environment and on human health due to the presence of hazardous substances are shown in the use and maintenance manual in the section on residual risks Information in addition to that indicated belo...

Page 34: ...40 170 180 140 115 1450 180 CONNECTIONS Water fittings 1 1 1 4 1 1 2 2 Condensate discharge mm 25 POWER SUPPLY Standard power supply 230 1 50 400 3 50 DIMENSIONS Length mm 650 850 850 1050 1050 1250 1...

Page 35: ...vels refer to the unit at full load in the rated test conditions and with available head of 30Pa The sound pressure level refers to unit with ductable supply and it is measured at a distance of 1m fro...

Page 36: ...H mm 551 754 754 954 954 1154 1154 I mm 310 310 310 310 315 315 315 L mm 300 300 300 300 470 470 470 M mm 450 650 650 850 850 1050 1050 N mm 500 500 500 500 630 630 630 O mm 350 350 350 350 450 450 45...

Page 37: ...02 202 H mm 1754 1754 1954 1954 I mm 315 315 315 315 L mm 525 525 525 525 M mm 1670 1670 1870 1870 N mm 630 630 630 630 O mm 450 450 450 450 P mm 1130 1130 1240 1240 Q mm 359 359 459 459 Key 1 SUPPLY...

Page 38: ...M23740N6 03 01 10 07 page 38...

Page 39: ......

Page 40: ...0 1489 573033 info clivet uk co uk CLIVET NEDERLAND B V Amersfoort Netherlands Tel 31 0 33 7503420 Fax 31 0 33 7503424 info clivet nl CLIVET TFA PVT LTD Bangalore INDIA Tel 91 80 25351617 Fax 91 80 2...

Reviews: