background image

 

M23740N6-03 01/10/07 

page 

34

 

 

TECHNICAL DATA 

 

Sizes 

31  41  51  71  91  101 121 142 182 202 242 

Cooling 

 

Cooling 

capacity 

1 kW 13,6 19,1 21,6 27,9 36,9 44,0 48,7 65,5 75,4 83,6  89 

Sensible 

capacity 

1 kW 9,82 13,7 15,7 20,3 26,5 31,8 35,6 47,1 54,9 60,2 64,9 

Total 

power 

input 

kW 0,3 0,3 0,5 0,6 0,8 1,1 1,5 1,5 2,2 2,2  3 

HEATING 

 

Heat 

output 

2 kW 26,6 36,7 42,4 53,1 72,4  86  94,7 125,9 143,8 159,1

174 

INTERNAL EXCHANGER

 

 
Front surface 

 

m

2

 

0,3 0,4 0,4 0,6 0,8 0,9 0,9 1,4 1,4 1,6 1,6 

Water 

content 

  l 

4  5,39 5,39 6,78 9,22 11,1 11,1 16,7 16,7 18,5 18,5 

Water 

flow-rate 

  l/s  0,6  0,85 0,97  1,2  1,75 1,97 2,16 2,83 3,23 3,60 3,88 

Pressure 

drop 

 

kPa 

24 29 36 24 38 26 30 20 25 33 38 

AIR HANDLING SECTION FANS (SUPPLY) 

Type of fans 

 

CGF 

Number 

of 

fans 

  1 1 1 2 1 1 1 2 2 2 2 

Standard 

air 

flow 

4  l/s  569  778  944  1166 1597 1889 2167 2638 3194 3472 3888 

Installed unit power 

5  kW  0,25 

0,25 

0,52 

0,6 

0,75 

1,1 

1,5 

1,5 

2,2 

2,2 

Max outside static 
pressure 

6 Pa 

85  93  80  70  140 170 180 140 115 1450 180 

CONNECTIONS

 

Water fittings 

 

 

1" 

1"1/4 

1"1/2 

2" 

Condensate discharge 

 

mm 

25 

POWER SUPPLY 

Standard power supply 

 

 

230/1/50 

400/3/50 

DIMENSIONS

 

Length 

  mm 650  850  850  1050 1050 1250 1250 1870 1870 2070 2070 

Depth 

 mm 500 500 500 500 670 670 670 670 670 670 670 

Height 

  mm 1700 1700 1700 1700 2000 2000 2000 2000 2000 2000 2000 

STANDARD UNIT WEIGHTS

 

Shipping 

weight 

 kg  96  117 123 140 185 210 215 250 260 290 295 

 
(1) water return 7°C and supply 12°C 
Ambient temperature 27°C/19.5 WB 
relative humidity 50% 
(2) water return 70°C and supply 60°C 
ambient temperature 20°C DB 
relative humidity 50% 

(3) CFG = centrifugal fan 
(4) Max outside static pressure 
(5) Standard motor 
(6) rated flow, maximum speed, including the air filter 

 
 
 

OPERATING LIMITS 

 

Sizes 

31 41 51 71 91 101 121 142 182 202 242 

Cooling 

 

Min air return temperature (W.B.) 

°C 

Max. air temperature return (D.B.) 

°C 

40 

Max water return temperature 

°C 

80 

Min. water supply temperature 

°C 

Heating 

 

Max water return temperature 

°C 

80 

Min. water return temperature 

°C 

30 

Max. air temperature return (D.B.) 

°C 

40 

Min. air temperature return (D.B.) 

°C 

 

DB = dry bulb 
WB = wet bulb 
16 bar water side high head-pressure 

BT06E005GB- 00

 

 

Summary of Contents for CF-V 101

Page 1: ...CF V 31 41 51 71 91 101 121 142 182 202 242 VERTICAL WATER DUCTABLE TERMINAL UNIT WITH DECORATIVE CABINET M23740N6 03 01 10 07...

Page 2: ......

Page 3: ...ATED AIR 12 E L E C T R I C A L C O N N E C T I O N 1 3 GENERAL 13 STANDARD UNIT ELECTRICAL DATA 13 CONNECTION TO THE MAINS 13 S T A R T U P 1 7 PRELIMINARY CHECKS 17 AERAULIC SYSTEM 17 WATER SYSTEM 1...

Page 4: ...nd the serial number Write them in the space below so that they are readily available when needed Type of unit _________________________________ Serial number _________________________________ Wiring...

Page 5: ...ICATIONS The manufacturer will not accept any responsibility and the warranty will lapse in the event of electric and or mechanical modifications Any modification which is not formally authorized and...

Page 6: ...orized entry GENERAL RISKS A smell of burning smoke or other indications of serious irregularity could signal the onset of situations liable to cause damage to persons or property or to the unit itsel...

Page 7: ...n the isolating switch on the power line to the unit is set to the OFF position and padlocked and post a warning sign Before removing the protective grilles or the fans themselves make certain the iso...

Page 8: ...s in force Legislative Decree 626 94 and following modifications Before starting the handling operations Value the critical points during handling stairs flights disconnected routes doors etc Verify t...

Page 9: ...responsible for evaluating the opportunity of installing drain tubes in conformity with the local regulations in force EN 378 3 Install the unit raised from the ground 4 avoid installations in places...

Page 10: ...connections are subject to temperatures near 0 C mix the water of the system with glycol protect the tubes with heating cables under the tubes insulation empty the system by verifying that o no taps...

Page 11: ...is unused for a long period TO AVOID THE FREEZE FORMING INSIDE THE COIL 1 If the unit or the relevant water connection are subjects to temperatures next to 0 C see RISK OF FREEZE in the GENERAL WARNI...

Page 12: ...es with a wide radius Consider whether it might be useful to equip them with deflectors especially if the air speed is high or if curves are tight FEATURES FOR DUCTS FOR TREATED AIR 1 The inner surfac...

Page 13: ...al Lay the cables far from power cables or cables having a different tension and that are able to emit electromagnetic disturbances Do not lay the cable near devices which can generate electromagnetic...

Page 14: ...peed By acting on trimmer TR1 anticlockwise the control power of the motor and consequently the flow rate of the unit are reduced 1 4 turn is equal to approximately 40 AC By acting on the trimmer cloc...

Page 15: ...ssed room control is supplied with a series of supports that make it possible to adapt it to the main civil series of plates refer to the instructions provided with the thermostat POSITIONING OF THE R...

Page 16: ...functionality On request Clivet provides the specifications for the communication protocol of its units and the necessary guidelines to connect them to RS485 The card for RS485 serial line must be con...

Page 17: ...deactivation When using antifreeze solutions make sure the glycol percentage is suitable for the type of use envisaged weight of ethylene glycol 10 20 30 40 Freezing point 4 C 9 C 15 C 23 C Safety tem...

Page 18: ...lles diffusers etc Pa L sec 1 2 3 B A C D D unit head flow rate curve A system calculated curve 1 project theorical working point 3 if the system has pressure drop lower than the project ones the work...

Page 19: ...mode using the relevant keys Set the P31 parameter 0 ECO Economic operation it prefers saving energy more than comfort in cooling mode the setECO is higher than the standard set in heating mode it is...

Page 20: ...visible with unit in COOLING 21 0 REMOTE ECO AUTO E c o S w i n g visible if the cooling heating choice is AUTOMATIC switch the thermostat on press and hold the ON OFF key for 4 seconds If the functi...

Page 21: ...y cooling heating If AUTO is displayed the switch from one mode to another is managed automatically from the unit and if this key is pressed no change occurs If the function is managed remotely via Mo...

Page 22: ...level sensor alarm CO Mode change in progress for the automatic mode is not an alarm EHH Lack of communication wrong thermostat connection SYS Fault internal to the control module ERR Configuration er...

Page 23: ...Fan status at cooling thermoregulator satisfied 0 stop 1 continuous 2 periodical 0 2 num 2 P22 FanOffHeat Fan status at heating thermoregulator satisfied 0 stop 1 continuous 2 periodical 0 2 num 0 P31...

Page 24: ...idity in the room where it is installed it is possible to use only the 4 front keys user programming Nolink operation HID TI not connected to CLIVET BUS the thermostat is powered by auxiliary power a...

Page 25: ...normal operation will resume preserving any modifications that have been made When setting fan speed you will go from AUTOMATIC where the speed of the fans is controlled automatically based on ambien...

Page 26: ...n problems between the device and the adjustment unit ADVANCED PROGRAMMING Hidden buttons for use by installer accessible by extracting the thermostat from its housing 5 6 not used keys accessible onl...

Page 27: ...ro Set point T amb C ON OFF p01 BandaLavoro Set point 3 speed Sizes 31 71 3 V 2 V 1 V p01 BandaLavoro Set point 3 V 2 V 1 V p01 BandaLavoro Set point WATER VALVE The system can control 2 ON OFF valves...

Page 28: ...ature alarm is not managed SINGLE PHASE RESISTANCES P01 Set Point ON OFF TWO PHASE RESISTANCES P01 Set Point DEHUMIDIFICATION The dehumidification control is managed by the network which is an upwards...

Page 29: ...r treatment coil to be able to offer maximum thermal exchange Therefore the unit must always operate with the filters installed and clean Cleaning and replacement of filters are very important in term...

Page 30: ...er The belt is tensioned correctly when the tolerances defined in the enclosed sketch are respected The tension of the belt should be checked after around 10 hours of operation Avoid the following sit...

Page 31: ...as well Refer to local actuation norms In Italy refer to the Ministerial Decree of 1 st December 2004 no 329 and following modifications which defines the performances to be executed the units of 1 st...

Page 32: ...CARRIED OUT BY AUTHORIZED SERVICE CENTERS BEFORE RESETTING AN ALARM IDENTIFY AND ELIMINATE ITS CAUSE REPEATED RESETS MAY CAUSE SERIOUS DAMAGES In certain machine configurations some safeties may be p...

Page 33: ...environment and on human health due to the presence of hazardous substances are shown in the use and maintenance manual in the section on residual risks Information in addition to that indicated belo...

Page 34: ...40 170 180 140 115 1450 180 CONNECTIONS Water fittings 1 1 1 4 1 1 2 2 Condensate discharge mm 25 POWER SUPPLY Standard power supply 230 1 50 400 3 50 DIMENSIONS Length mm 650 850 850 1050 1050 1250 1...

Page 35: ...vels refer to the unit at full load in the rated test conditions and with available head of 30Pa The sound pressure level refers to unit with ductable supply and it is measured at a distance of 1m fro...

Page 36: ...H mm 551 754 754 954 954 1154 1154 I mm 310 310 310 310 315 315 315 L mm 300 300 300 300 470 470 470 M mm 450 650 650 850 850 1050 1050 N mm 500 500 500 500 630 630 630 O mm 350 350 350 350 450 450 45...

Page 37: ...02 202 H mm 1754 1754 1954 1954 I mm 315 315 315 315 L mm 525 525 525 525 M mm 1670 1670 1870 1870 N mm 630 630 630 630 O mm 450 450 450 450 P mm 1130 1130 1240 1240 Q mm 359 359 459 459 Key 1 SUPPLY...

Page 38: ...M23740N6 03 01 10 07 page 38...

Page 39: ......

Page 40: ...0 1489 573033 info clivet uk co uk CLIVET NEDERLAND B V Amersfoort Netherlands Tel 31 0 33 7503420 Fax 31 0 33 7503424 info clivet nl CLIVET TFA PVT LTD Bangalore INDIA Tel 91 80 25351617 Fax 91 80 2...

Reviews: