Page 8 of 11
Priming:
After 100,000 cycles, the stroke is reduced and rivets are not set by one operation, then the
tool needs to be oiled. Please use the attached bottle of lubrication oil in the box.
1.
Disconnect air supply to tool and switch ON/OFF valve (48) to OFF position.
2.
Remove seal screw (84) and seal (83). (See figure 3)
3.
Screw the priming pump oil into the bleed screw hole.
Press down and release several times until resistance is felt.
(See figure 4)
4.
Remove the priming pump and the excessive oil will
flow out. Clean out the excessive oil and replace the seal
screw and seal.
Fig 3
Fig 4