AIR-CONDITIONERS
P
age
www.
veco-na.com
4 SEA WATER CIRCUIT
4.1 - SEA WATER PUMP
The sea water pump must be of the correct size for the Compact unit
.
Most installations require a centrifugal pump, and close attention to
the installation requirements must be made to ensure trouble-free
operation.
Centrifugal pumps are not self-priming and MUST be mounted with the
discharge below the waterline, with a rising hose run through the strainer
and on to the pump, and with a scoop intake strainer facing towards
the bow of the vessel.
4.2 -
LOCATION
4.2 - A
4.2 - B
4.2 - C
4.2 - D
Install the
sea water
pump
so that i
ts
outlet
is vertical,
and a
s far
below the
water line
as possible
.
S
coop intake strainer must point
towards the bow.
The
hose must make a continual rise from the ball valve,
through the strainer, and into the pump inlet. All items in
the pump circuit must be as far below the water line as
possible. Use wire-reinforced hose for this section, and
secure hoses using double stainless steel hose clamps
of high quality.
The
hose runs from the ball valve to the inlet of the pump,
via the strainer should
be as short as possible
.
4.3 -
SECURING
Secure
the pump
using screws or bolts. Use
anti-vibration dampers if provided with pump.
.
STERN
BOW
MAX 1 mt
NOTE: The restrictions here do not
apply to DC or AC diaphragm pumps.
These can be mounted above the