CLIMIA CMG 100 Operating Manual Download Page 5

5

Humidity measuring unit CMG 100

The units are shipped in sturdy 
transport packaging. Check the 
unit immediately after delivery and 
make a note of any damage (please 
take photos of the damage) or 
missing parts on the delivery note. 
Inform the forwarding agent and 
contractual partner. 
Please keep the packaging safely for 
any returns. 
Claims under guarantee made at a 
later date will not be accepted.

5.0 Transportation and 

packaging 

3.0 Intended use

The product is used for non-invasive, 
digital humidity measurement. It 
is ideal for measuring the moisture 
content of concrete, wood and 
other building materials. The unit 
can be used to check whether the 
surface is ready for painting or 
coating. Large surfaces can also be 
measured quickly and effectively 
using the signal function. The user 
can concentrate on the object 
being measured without having to 
constantly read the measured values 
on the display. The unit beeps when 
the humidity level exceeds the limit. 
The limit value is adjustable. The unit 
offers a wide measuring spectrum 
with a measuring depth of about 
20 - 40 mm and has a display for 
min/max values and for low battery. 
The unit is powered by a 9 V block 
battery. It also has an automatic 
switch-off function.

For safety and approval reasons, you 
must not convert and/or modify 
the product. If you use the product 
for purposes other than those 
described above, the product may 
be damaged. In addition, improper 
use can cause hazards such as short-
circuits, fire, etc. Read the operating 
manual carefully and keep it in a 
safe place. Only pass the product on 
to third parties together with the 
operating manual.

The product complies with the legal, 
national and European requirements. 
All company names and product 
designations contained herein 
are trademarks of their respective 
owners. All rights reserved.

2.0 Guarantee

As a prerequisite for any warranty 
claims to be considered, it is 
essential that the ordering party or 
its representative completes and 
returns the "certificate of guarantee" 
to Climia Intakt GmbH at the time 
when the units are purchased and 
commissioned.
The guarantee conditions are 
listed in the "General terms 
and conditions of business and 
supply". Furthermore, only the 
parties to a contract can conclude 
special agreements beyond these 
conditions. In this case, contact 
your contractual partner 
 in the first instance.

Disposal of packaging

All products are packed for 
transport in environmentally 
friendly materials. Make a valuable 
contribution to reducing waste 
and sustaining raw materials. Only 
dispose of packaging at approved 
collection points.
 

Disposing of the units and their 

components

Only recyclable materials are used 
in the manufacture of the units and 
components.
Help protect the environment 
by ensuring that the units or 
components (for example batteries) 
are not disposed of in household 
waste, but only in accordance 
with local regulations and in an 
environmentally safe manner, e.g. 
using authorised disposal and 
recycling specialists or council 
collection points.

4.0 Environmental 

protection and 

recycling

Summary of Contents for CMG 100

Page 1: ...CLIMIA Humidity measuring unit CMG 100 Operating manual Edition 1 0 English ...

Page 2: ......

Page 3: ...ept in the vicinity of the installation location or on the unit itself Subject to modifications No liability accepted for errors or misprints 1 0 Safety information 4 2 0 Guarantee 5 3 0 Intended use 5 4 0 Environmental protection and recycling 5 5 0 Transportation and packaging 5 6 0 Operation 6 7 0 Commissioning 7 8 0 Use 7 9 9 0 Care cleaning and maintenance 9 10 0 Scope of delivery 9 11 0 Tech...

Page 4: ...specialist or a specialist workshop If you still have questions that are not answered in this operating manual please contact our technical customer service or other professionals 1 0 Safety information Battery rechargeable battery When inserting the battery rechargeable battery ensure that the polarity is correct Remove the battery rechargeable battery if you are not going to use the unit for a l...

Page 5: ...e can cause hazards such as short circuits fire etc Read the operating manual carefully and keep it in a safe place Only pass the product on to third parties together with the operating manual The product complies with the legal national and European requirements All company names and product designations contained herein are trademarks of their respective owners All rights reserved 2 0 Guarantee ...

Page 6: ...6 On Off key 7 UP key 8 Battery compartment on the back 6 0 Operation Fig 2 LC Display 9 10 11 12 13 14 15 18 17 16 Legend 9 Low battery indicator 10 HOLD data storage symbol 11 DRY status symbol 12 RISK status symbol 13 WET status symbol 14 MIN symbol 15 Min humidity level 16 Max humidity level 17 MAX symbol 18 Current humidity level ...

Page 7: ...ng field of the sensor the measured value increases abruptly due to strong reflections If the spherical head is held in corners e g tile joints or window niches the measured value is generally higher because there is more substance in the scattering field of the measuring head There must be a distance of more than 8 to 10 cm from the corner Hold the measuring unit at its outermost end as far away ...

Page 8: ... on the display in addition to the last measured value If the HOLD mode is not terminated by pressing the MEAS key 5 the measured values are shown on the LC display for another 30 seconds before the measuring unit switches off automatically Before this time has elapsed press the MEAS key 5 in HOLD mode to exit HOLD mode and perform further measuring procedures After finishing your measurements swi...

Page 9: ...aintenance WET The value can be set from 50 to 100 The factory default setting is 60 Press the SET key 4 to confirm your selection The LC display switches back to the initial mode HOLD The limit value is stored permanently until it is next changed Backlight If no backlight is switched on press and hold the UP key 7 for some time to switch on the backlight The LC display is illuminated by white LED...

Page 10: ...on 1 unit Accuracy 1 unit Measuring range 0 100 units Measuring depth mm 20 40 Screw connection tripod mm Inches 6 3 1 4 Operating conditions C r H 0 to 50 C 70 Storage conditions C r H 10 to 60 C 80 relative humidity non condensing Dimensions H x W x D mm 194 x 54 x 34 Weight g 143 without battery We reserve the right to modify the dimensions and design as part of the ongoing technical developmen...

Page 11: ...ill capable of penetrating thick concrete walls The water required for setting in the production of concrete mortar and plaster etc may only be diffused after 1 2 months Even moisture trapped in the masonry after high water or a flood is released very slowly The same is also true of moisture contained in stored materials for example The moisture water vapour released from parts of a building or ma...

Page 12: ... content becomes greater as the temperature rises Building materials and structures are capable of absorbing considerable volumes of water such as brick 90 190 l m heavy concrete 140 190 l m and limestone 180 270 l m The drying of moist materials such as masonry is effected as follows The moisture moves from the inside of the material to its surface Evaporation occurs on the surface Transfer of wa...

Page 13: ...sation heat The energy transferred to the air from the condenser consists of 1 The amount of heat derived beforehand in the evaporator 2 The electrical drive energy 3 The condensation heat released by liquefying the water vapour Energy must be supplied when liquid is converted into a gas This energy is designated as evaporation heat It does not cause any increase in temperature but is required to ...

Page 14: ...14 CLIMIA Notes ...

Page 15: ...15 Humidity measuring unit CMG 100 ...

Page 16: ...Intakt GmbH Climia Klima und Wärmetechnik Niemeierstraße 13 D 32758 Detmold ...