10
CLIMIA
Building material
Humidity range (unit)
Humidity status
Plaster
< 30
DRY
30 - 60
RISK
> 60
WET
Cement
< 25
DRY
25 - 50
RISK
> 50
WET
Wood
< 50
DRY
50 - 80
RISK
> 80
WET
11.0 Technical data
Unit data
CMG 100
Power supply
1 x 9 V battery
Battery life
Hours.
50
Current consumption
μA
4.9
Resolution
1 unit
Accuracy
± 1 unit
Measuring range
0-100 units
Measuring depth
mm
20-40
Screw connection (tripod)
mm / Inches
6.3 / 1/4“
Operating conditions
°C / r.H. %
0 to +50 °C / <70 %
Storage conditions
°C / r.H. %
-10 to + 60 °C / <80 % relative humidity
(non-condensing)
Dimensions (H x W x D)
mm
194 x 54 x 34
Weight
g
143 (without battery)
We reserve the right to modify the dimensions and design as part of the ongoing technical development process.
Humidity limit ranges
The following limit ranges can be used as a reference.