background image

10/16

2009/10 - Indice de révision : C - Code : 0033500

The CLIMEXEL 850E/950E dehumidifi er features an IP24 protection rating meaning it is splash proof and cannot be 
penetrated by solid objects larger than 12 mm (fi ngers).

In France, it must be installed beyond protection volume 2:

-    3.5 meters from a body of water.

 

-    2.4 meters from a bath, sink or any other water source.  

Nevertheless, if a 30mA differential circuit breaker is mounted at the head of the dehumidifi er's dedicated power line 
(to be installed by a qualifi ed electrician), it may be placed in protection volume 2:

-    2 meters from a body of water.

 

-    0.6 meters from a bath, sink or any other water source.

The dehumidifi er must be plugged into an earthed outlet.

Before plugging the device in, check the following:
•  The voltage corresponds to that indicated on the information plate.
•  That the electrical network can support the operation of the dehumidifi er (call in a qualifi ed electrician if necessary).
•  That the plug on the power cable is compatible with the outlet. 

In case of doubt, have the installation examined, and if necessary modified, by a qualified electrician.  The 
manufacturer will not be held liable in the event of failure to respect these safety measures.

Important: Never allow current carrying parts to come into contact with water: danger of a short circuit!

•  The dehumidifi er is safe. However, as with other electrical appliance, it should be operated with care.
•  Do not allow children to play with or around the device. 
•  Do not clean the dehumidifi er by spraying it or using solvents.
•  Do not insert any object into the dehumidifi er gratings.
•  Disconnect from the mains before cleaning the unit or any of its components.
•  Never connect the device to an electrical outlet using an extension cord. If an outlet is not available, one should be  
  installed by a licenced electrician.
•  

WARNING:   Interventions, other than regular maintenance, cleaning or replacement of the fi lter, should be carried 

out by an approved after sales technician or by the Climexel supplier. Failure to respect this instruction could result in 
the cancellation of the warranty.

1,50 m

2,00 m

VOLUME 2

2,50 

m

VOLUME 1

VOLUME 2

1,50 m

2,00 m

1,50 m

1,50 m

VOLUME 0

Standard C15-100

safetY

Summary of Contents for 850E

Page 1: ... a Climexel dehumidifier This document describes the device s numerous FEATURES And its technical data Please read this document carefully before installing or operating the dehumidifier This manual should be kept at hand so that it may be consulted when necessary Before switching the dehumidifier on for the first time ensure that it has been standing upright for at least two hours ...

Page 2: ...the outlet In case of doubt have the installation examined and if necessary modified by a qualified electrician The manufacturer will not be held liable in the event of failure to respect these safety measures Important Never allow current carrying parts to come into contact with water danger of a short circuit The dehumidifier is safe However as with other electrical appliance it should be operat...

Page 3: ...ere it may be damaged by chemicals Where there is a risk of interference by foreign objects This product is not made for DIY repair hoW it WorKs Your CLIMEXEL dehumidifier controls the Relative Humidity by drawing air in and over the cooling elements upon contact with the cold excess moisture in the air condenses out and trickles down This condensate water is channelled into a fixed drain The drie...

Page 4: ...s installed in a pool room connect it to the mains via a transformer or a break switch in accordance with local regulations governing electrical installations Do not open doors or windows unless absolutely necessary while the dehumidifier is running Wall mounting The unit may be placed on the floor or mounted on the wall Make sure that all four feet are touching the ground Wall mounting Fix the su...

Page 5: ...w or high speed setting The corresponding LED 3 indicates the setting selected Lo low or Hi high Digital display 4 The digital display 4 shows relative humidity in the enclosed area Compressor 6 The COMP LED 6 lights up when the compressor is running There is an automatic time delay of three minutes before the compressor re starts working Defrosting The CLIMEXEL 850E 950E dehumidifier features a d...

Page 6: ...er water CAUTION In very cold weather conditions precautions should be taken to prevent the drainage pipe from freezing cleaning Disconnect from the mains before cleaning the unit or any of its components Cleaning the air filter Air circulation is impeded and the efficiency of the dehumidifying and air purifying functions decrease when the filter is dirty It is therefore good practice to clean the...

Page 7: ...ent in operation A 4 5 6 Current upon start up A 18 24 Dehumidification at 32 C RH 90 at 30 C RH 70 L 24h L 24h 65 45 80 60 Refrigernat R407C g 700 750 Air flow rate fan at high speed m3 h 500 680 Ambient temperature C 7 35 Dimensions w x h x d mm 660 x 750 x 345 Weight net kg 39 44 Compliant with EC directive 73 23 CE LVD Specifications may change without prior notice EC No 842 2006 R407C is a pr...

Page 8: ...16 16 2009 10 Indice de révision C Code 0033500 S A au capital de 7 000 000 1 R C S Rennes B 333 263 846 000 37 ...