background image

 

 

 

Part Number

Comments

Inspector Name

Date

MODEL NUMBER:

DATE OF MANUFACTURE:

Inspection:

O

ffi

cial periodic inspection must be made at least semiannually. The inspection must be performed by a 

quali

fi

ed person other than the intended user. If severe weather or conditions exist then inspections must be 

carried out more frequently. All inspection results must be logged in the space provided above.

 

 

1.

  Inspect swivel to make sure it is 

fl

ush with mounting surface.

 

2.

  Make sure all labeling is a

ffi

xed to the unit.

 

3.

  Make sure the unit can rotate 360° and D-ring can 

fl

ip from side to side.

 

4.

  When reusing a previously drilled hole, inspect for for debris or wallowing.

 

5. 

 Record inspection results in the space provide above.

*If any damage that could a

ff

ect the strength or operation of the device, or unsafe condi-

tions are found, proper disposal is required. The anchorage connector must be rendered 

unusable and then properly discarded.

MAINTENANCE, CLEANING AND STORAGE

Cleaning periodically will prolong the life and proper functioning of the product. The frequency 

of cleaning should be determined by inspection and by severity of the environment. Clean with 

compressed air and/or a sti

ff

 brush using plain water or a mild soap and water solution. Do not use 

any corrosive chemicals that could damage the product. Wipe all surfaces with a clean, dry cloth 

and hang to dry, or use compressed air. When not in use, store anchorage connectors in a cool, dry, 

clean environment, out of direct sunlight and free of corrosive or other degrading elements.

INSPECTION AND MAINTENANCE LOG

Summary of Contents for SWY100N-MTU

Page 1: ...T READ AND UNDERSTAND ALL INSTRUCTIONS FAILURE TO DO SO MAY RESULT IN SERIOUS INJURY OR DEATH USERS SHOULD BE FAMILIAR WITH PERTINENT REGULATIONS GOVERNING THIS EQUIPMENT ALL INDIVIDUALS WHO USE THIS PRODUCT MUST BE PROPERLY INSTRUCTED ON HOW TO USE THE DEVICE AVOID CONTACT WITH PHYSICAL HAZARDS THERMAL CHEMICAL ELECTRICAL ETC MAKE ONLY COMPATIBLE CONNECTIONS ...

Page 2: ...nents are found the anchorage connector must be immediately removed from service USE LIMITATIONS 1 The anchorage connector is designed to be used in temperatures ranging from 40ºF to 130ºF 40 C to 54 C 2 Do not expose the anchorage connector to chemicals or harsh solutions which may have a harmful effect 3 Do not alter or modify this product in anyway 4 Do not use install equipment without proper ...

Page 3: ...3 2mm 180 360 5 5 139 7mm 2 25 ø 57 15mm 3 76 2mm 1 25 4mm Tensile Strength UTS 10 000 lbf 44kN Working Load 2 000 lbs 907kg Weight 1 2 lbs 544 3g Materials Zinc Plated Steel LOADING CONDITIONS DIAGRAM ACCEPTABLE ACCEPTABLE IMPROPER ACCEPTABLE ...

Page 4: ...ns a grade 5 grade 8 or equivalent bolt no shorter than 4 100mm with a locking nut and washer must be used Swivel anchor must be flush with steel surface A 16mm bolt of equal strength may be used in place of a 5 8 11 for metric applications 1 Use a proper drill and bit for steel 2 Drill a 5 8 16mm hole no less than 75 6mm deep 3 76mm away from any edge 3 Hole must be straight and perpendicular to ...

Page 5: ...5 114mm deep 9 229mm away from any edge 3 Hole must be straight perpendicular to surface 4 Hole must be free of debris 5 Concrete strength must be at least 3000psi 20 7MPa and no less than 7 178mm thick 9 229mm drill 3 4 19mm Ø min from any edge 7 178mm min Embedment Depth 4 5 min 114mm Torque 110 ft lbs 149Nm ...

Page 6: ... engineer or qualified person Back Plate to be used with 5 8 16mm bolts or all thread Drill hole perpendicular into surface so bolt can pass freely through the substrate Nut must be fully threaded on the bolt to insure maximum strength ratings and integrity of anchor Bolt or All thread and nut not included with Back Plate Torque Range 75 to 90 ft lbs 100 120Nm Grade 5 or 8 bolt 5 8 11 x 1 3 4 Weld...

Page 7: ...rease meeting Sinopec specification Q SH303 242 2007 or equivalent 1 Strip decking to expose the Straight Loop Insert 2 Ensure that anchorage was properly installed Orange indicator should be flush with concrete surface and at least 9 from any edge or corner Concrete should be at least 6 thick and cured to a minimum of 3000 psi 3 Remove plastic bolt and o ring using 1 2 allen wrench 4 Save plastic...

Page 8: ...Steel Mounting kit SWY1CSA 55P CTS Concrete Hardware Kit SWY100C MTU CTS Swivel with Concrete Mounting Kit SWP100N KIT CTS Weld on Mounting Kit SWX100N QPQ CTS Backing Plate Only SWY100P MTU CTS Swivel with Straight Loop Insert Mounting kit SWY1PBA 325 CTS Straight Loop Insert Mounting Kit SL4625C ZNO CTS Straight Loop Insert ...

Page 9: ...esults in the space provide above If any damage that could affect the strength or operation of the device or unsafe condi tions are found proper disposal is required The anchorage connector must be rendered unusable and then properly discarded MAINTENANCE CLEANING AND STORAGE Cleaning periodically will prolong the life and proper functioning of the product The frequency of cleaning should be deter...

Page 10: ...NOTES ...

Page 11: ...NOTES ...

Page 12: ...scretion ClimbTech reserves the right to require that the defective item be returned to its plant for inspection before determining the appropriate course action Warranty does not cover equipment damage resulting from wear abuse damage in transit failure to maintain the product or other damage beyond the control of ClimbTech ClimbTech shall be the sole judge of product condition and warranty optio...

Reviews: