Part Number
Comments
Inspector Name
Date
MODEL NUMBER:
DATE OF MANUFACTURE:
Inspection:
O
ffi
cial periodic inspection must be made at least semiannually. The inspection must be performed by a
quali
fi
ed person other than the intended user. If severe weather or conditions exist then inspections must be
carried out more frequently. All inspection results must be logged in the space provided above.
1.
Inspect swivel to make sure it is
fl
ush with mounting surface.
2.
Make sure all labeling is a
ffi
xed to the unit.
3.
Make sure the unit can rotate 360° and D-ring can
fl
ip from side to side.
4.
When reusing a previously drilled hole, inspect for for debris or wallowing.
5.
Record inspection results in the space provide above.
*If any damage that could a
ff
ect the strength or operation of the device, or unsafe condi-
tions are found, proper disposal is required. The anchorage connector must be rendered
unusable and then properly discarded.
MAINTENANCE, CLEANING AND STORAGE
Cleaning periodically will prolong the life and proper functioning of the product. The frequency
of cleaning should be determined by inspection and by severity of the environment. Clean with
compressed air and/or a sti
ff
brush using plain water or a mild soap and water solution. Do not use
any corrosive chemicals that could damage the product. Wipe all surfaces with a clean, dry cloth
and hang to dry, or use compressed air. When not in use, store anchorage connectors in a cool, dry,
clean environment, out of direct sunlight and free of corrosive or other degrading elements.
INSPECTION AND MAINTENANCE LOG
Summary of Contents for SWY100N-MTU
Page 10: ...NOTES ...
Page 11: ...NOTES ...