33
will not be sent during the time period you set in Entry Delay 1 for full arm mode. On the
other hand, if the correct Pin code has not entered during the period, Control Panel
raises an alarm and sends alarm report.
If Door Contact (DC) or PIR Detector (IR) is set as
Entry Delay 1 for Full Arm
attribute,
the system will get into counting down period (Away entry timer) while the DC or IR is
triggered under full arm mode.
Entry Delay 2 for Full Arm
:
this is for you to set Entry Delay Timer. It is allowed to use
correct Pin code to disarm the full alarm mode and the alarm reporting will not be sent
during the time period you set in Entry Delay 2 for full arm mode. On the other hand, if
the correct Pin code has not entered during the period, Control Panel raises an alarm
and sends alarm report.
If Door Contact (DC) or PIR Detector (IR) is set as
Entry Delay 2 for Full Arm
attribute,
the system will get into counting down period (Away entry timer) while the DC or IR is
triggered under full arm mode
Exit Delay for Full Arm
: this is for you to set Exit Delay Timer. While the system gets
into
Away arm mode
by Control Panel, Remote Controller(RC) or Remote Keypad
(KP), the Exit Delay timer starts counting down.
During the counting down period, pressing the Arm Button of the RC can restart the
counting. In addition, you can press Disarm Button of the RC to stop the counting and
return to Alarm off mode.
Entry Delay 1 for Home Arm
: this is for you to set Entry Delay Timer. It is allowed to
use correct Pin code to disarm the home alarm mode and the alarm reporting will not
be sent during the time period you set in
Entry Delay 1 for Home Arm
. On the other
hand, if the correct Pin code has not entered during the period, Control Panel raises an
alarm and sends alarm report.
If Door Contact (DC) or PIR Detector (IR) is set as
Entry Delay 1 for Home Arm
attribute, the system will get into counting down period (Away entry timer) while the
DC or IR is triggered under full arm mode.
Entry Delay 2 for Home Arm
:
this is for you to set Entry Delay Timer. It is allowed to
use correct Pin code to disarm the home alarm mode and the alarm reporting will not
be sent during the time period you set in
Entry Delay 2 for Home Arm.
On the other
hand, if the correct Pin code has not entered during the period, Control Panel raises an
alarm and sends alarm report.
If Door Contact (DC) or PIR Detector (IR) is set as
Entry Delay 2 for Home Arm
attribute, the system will get into counting down period (Away entry timer) while the DC
or IR is triggered under full arm mode
Alarm Length
: this is for you to select the external siren duration when an alarm is
activated. Options are disable (no siren alarm) and 1-min to 15-min in 1- min
increments.
Sound Setting
(The Control Panel does not have a built-in buzzer, the Sound Setting is used to control
external siren or bellbox included in the system..)
Entry Delay Sound for Full Arm
:
this is for you to decide whether the system should
sounds count-down beeps and volume of beep during the entry delay time in the full
arm mode.
Exit Delay Sound for Full Arm
: this is for you to decide whether the system should
sounds count-down beeps and volume of beep during the exit delay timer in the full arm
mode.
Entry Delay Sound for Home Arm
:
this is for you to decide whether the system should
sounds count-down beeps and volume of beep during the entry delay time in the home