background image

                                                                                                                                                             

     

 

2

¾

 Request 

for 

Home

 mode during 

Arm

 mode. 

¾

 Request 

for 

Force

 

arm

z

 

Fault LED (Amber): 

z

 

Flash: system failure (panel tamper, AC fault, sensor temper, sensor out of order, open door) 

z

 

On: Alarm Memory (depend on Control Panel). 

z

 

Power 

z

 

Remote keypad uses one EL123AP 3V Lithium battery as its power source.   

z

 

Remote keypad can also detect the battery status. If the battery voltage is low, the Active LED will flash (

Amber

 in 

Test 

mode

 or

 Blue

 in 

Normal mode

) during operation. The Low battery signal will be sent along with regular signal 

transmissions to the Control Panel for displaying the status accordingly. 

z

 

Before shipment, the battery is pre-installed by the factory. Pull out the battery insulator to activate battery. 

z

 

When changing battery, press the tamper switch a couple time after removing old battery to discharge, then insert the 
new battery. 

z

 

Power Saving Feature 

z

 

When idle, Remote keypad is in 

Stand-by

 mode and uses no power.    It will activate and 

wake-up

 for 5 seconds when 

any key is pressed. 

z

 

After 5 seconds of key inactivity, the power goes off and it returns t

o Stand-by 

mode.   

z

 

Upon completion of a command input, the power goes off and Remote keypad returns to

 Stand-by 

mode. 

z

 

Test Mode 

z

 

Remote keypad can be put into Test mode by entering the Keypad PIN code (default:

 0000

) followed by 

  key.    The 

Active Amber LED will turn on along with a long beep. 

z

 

To exit Test mode, press 

 key

 twice

, Remote keypad will sound a long beep and the Active LED will turn off

then 

Remote keypad returns to Normal Operation mode.    Otherwise, Remote keypad will automatically exit Test mode after 

5 minutes and return to

 

Normal Operation mode. 

<NOTE> 

&

 

The Test Mode is helpful for bypassing Remote keypad Tamper alarm when installing, replacing low batteries or 
removing to different mount site. 

&

 

When Remote keypad is in Test mode, it operates as 

wake-up

 condition and will NOT disconnect after 5 seconds. 

Test Mode Function: 

„

 Press 

 key and then 

7

 key — Transmit Remote keypad learn signal   

„

 Press 

 

key and then 

key — Enable Dual-key Panic Alarm function   

„

 Press 

 key and then 

key — Enable Dual-key Fire Alarm function 

„

 Press 

 key and then 

key — Enable Dual-key Medical Alarm function 

„

 Press 

 key and then 

key — Disable all Dual Key function (

Default

„

 Press 

 key and then 

6

 key — Edit Keypad Pin Code   

Enter 

Old

 Keypad Pin Code and then press 

Χ

 key 

Enter 

New

 a new 4-digit Keypad Pin Code and then press

 # 

key

.

 

„

 Press 

 

key

 twice

 — to leave the Test Mode

.

 

„

 Press 

 key and then

 8 

key — Enable Arm/ Home without PIN Code function 

„

 Press 

 key and then

 9 

key — Enable Arm/ Home with Control Panel User PIN Code function (

Default

z

 

Tamper Protection 

z

 

The keypad is protected against any attempt to open the lid or to detach keypad from its mounting surface. 

z

 

Tamper protection is disabled when the keypad is in Test Mode.     

z

 

Installation Procedures 

Step 1. 

Put the Control panel into learning mode, . 

Step 2. 

Adding remote keypad into the Control Panel: 

 

Test Mode Learning: 

I. 

Put remote keypad in Test mode by entering KP PIN code (default: 

0000

), then press 

 key. The Active 

Amber LED will turn on along with a long beep sound. 

II. Press 

 key then 

7

 key. Remote keypad will sound a long beep. 