6
indicate there are still empty zones for
DECT devices. If CTC-1041RV has
learned 4 DECT devices and there are no
more zones for DECT devices, the red
LED will flash quickly.
You can clear Zone 1 and Zone 2 for
DECT devices to be learned in by
pressing and holding CTC-1041RV’s
green reset button for 6 seconds until you
hear a long beep that indicates the
devices in Zone 1 and Zone 2 have been
simultaneously removed. Now you can
learn DECT devices into Zone 1 and Zone
2.
The above method, however, cannot
create available zones for more DECT
devices if CTC-1041RV has already
learned in 4 DECT devices and none of
them are in Zone 1 or Zone 2.
3. Press and hold the CP-23/WTRVS button
for 8 seconds until you hear a long beep.
The red LED of CP-23/WTRVS is turned
on. CP-23/WTRVS is now in learning
mode.
4. Now the LED of CP-23/WTRVS turns from
red to green. The green LED blinks. The
Control Panel will emit two quick beeps.
Afterwards CP-23/WTRVS will emit one
beep and its green LED will be turned on
and then go off instantly. CP-23/WTRVS
has been successfully learned in.
<
<
N
N
O
O
T
T
E
E
>
>
You cannot learn in the same CP-
23/WTRVS twice.
5. Check if CP-23/WTRVS has been learned
in successfully. Press the CP-23/WTRVS
button and you will hear continuous beeps
from
CP-23/WTRVS.
When
CP-
23/WTRVS beeps, the CTC-1041RV will
respond with 1 beep to indicate that CP-
23/WTRVS is within the operation range.
6. Press the reset and help buttons at the
same time to exit learning mode. The red
LED will dim to indicate that CTC-1041RV
is back to idle mode.
2.4. Removing Pendant #1 &
#2
CTC-1041RV can be programmed to remove
Pendant #1 & #2 by
Commands 80, 81 or 82.
Please refer to
3.2 Programming Your
1041RV: Commands 80, 81
or
82
for details.
To remove WTRVS, CP-23 and CTC-808RV,
you have to remove it from the Control Panel.
Summary of Contents for CTC-1041RV
Page 1: ...c August 12 2013 ...