1
1. Application Overview
1.1. Identifying The Parts
TOP VIEW
1. GREEN LED
—
ON: AC Power is ON.
—
FLASH every second: AC Power
failure
—
FLASH every 2 seconds: Panel or
Device Low battery
—
SLOW FLASH: Line Fault (on and off
at every second)
—
QUICK FLASH every 2 seconds:
Supervision failure
2. RED LED
—
ON: Off-hook / Waiting retry pause /
Ready to enter Programming Mode
(before entering PIN code)
—
FLASH:
Programming
Mode
/
Pendant Learning Mode
3. GREEN RESET BUTTON
—
Press once in normal mode to reset
mobility timer (see command 44)
—
Before CTC-1041RV dials out for
alarm reporting, press once to cancel
the alarm reporting
—
During or at-the-end of conversation,
press once to terminate two-way
voice communication
—
In Programming Mode, press once to
return to Idle Mode
—
Press & hold for 3 sec: dial the Non-
Emergency call. (See section 4.1.2.)
—
Press & hold for 6 sec: enter
Learning Mode
—
Press & hold for 16 sec: disable
mobility setting
4. RED HELP BUTTON (with backlight)
—
Back-lit disigned for easy access at
night
—
Backlight illuminates when reporting
and off-hook
—
Backlight flashes during the waiting
period until help arrives
5. Microphone
6. Speaker
REAR VIEW
7. Phone Jack marked
—
Telephone unit connection
8. Line Jack marked
—
Phone line connection from wall
9. DC Jack
—
DC 12V 1A power adapter
connection
10. Battery Switch
11. Local Programming Telephone
Unit Input
—
A special telephone cord to connect
CTC-1041RV and your phone unit
for Local Programming (optional).
Summary of Contents for CTC-1041RV