background image

<

<

 

 

N

N

O

O

T

T

E

E

 

 

>

>

 

 

 

After you have set one function by sliding the DIP switch, you have to press Test Button to confirm the setting.    

 

Only 

1

 switch of Dip Switch 1~4 can be set to ON position at a time. 

 

 

A

A

c

c

c

c

e

e

s

s

s

s

o

o

r

r

i

i

e

e

s

s

 

 

I

I

n

n

c

c

l

l

u

u

d

d

e

e

d

d

 

 

 

 

 

 

a)  1 Magnet 

b)  2 White Caps                              

c)  2 Screws 

d)  2 Wall Plugs 

 

 

L

L

E

E

D

D

 

 

I

I

n

n

d

d

i

i

c

c

a

a

t

t

o

o

r

r

 

 

 

 

The LED will light up in the following situations: 

 

When the Universal Transmitter is activated by connected device. 

 

When the cover is opened and the tamper switch is violated. 

 

The LED indicator will flash twice when receiving acknowledge from the Control Panel. 

 

 

B

B

a

a

t

t

t

t

e

e

r

r

y

y

 

 

 

 

 

The Universal Transmitter  uses one 

CR2  3V Lithium battery

  as its power source.  Please note: 

ALWAYS

  replace 

battery with the correct size and voltage.   

 

When the Universal Transmitter is low in battery, the LED will flash and a low battery signal will be sent to the Control 

Panel along with regular signal transmissions for the Control Panel to display the status accordingly. 

 

When changing batteries, after removing the old batteries, press the Tamper Switch twice to fully discharge before 

inserting new batteries. 

 

 

S

S

u

u

p

p

e

e

r

r

v

v

i

i

s

s

o

o

r

r

y

y

 

 

S

S

i

i

g

g

n

n

a

a

l

l

 

 

(

(

w

w

h

h

e

e

n

n

 

 

t

t

h

h

e

e

 

 

D

D

i

i

p

p

 

 

S

S

w

w

i

i

t

t

c

c

h

h

 

 

5

5

 

 

i

i

s

s

 

 

O

O

N

N

)

)

 

 

 

 

 

 

 

After installation,  UT-15  will automatically transmit Supervisory Signals periodically to the Control Panel at random 

intervals of 15-18 minutes. 

 

Failure of the Control Panel to receive a preset Device  Contact  signal, the Control Panel will display the particular 

Device Contact is experiencing an out-of-signal problem. 

 

 

G

G

e

e

t

t

t

t

i

i

n

n

g

g

 

 

S

S

t

t

a

a

r

r

t

t

e

e

d

d

 

 

 

Remove the fixing screw and cover assembly.   

 

Insert the “

CR2 3V

” battery into the battery holder connecting the polarity correctly. 

 

Choose the type of connected device by sliding one Dip Switch on Universal Transmitter (Dip Switch 1, 2, 3, or 4) to 
ON position and then press Test button to confirm settings.   

 

Put the Control Panel into learning mode, refer to Control Panel manual for detail. 

 

Press the Universal Transmitter’s test button. 

 

Refer to Control Panel manual to complete the learn-in process. 

 

After the Universal Transmitter is learned-in, place the Control Panel into (

Walk Test)

 mode, hold the transmitter at 

desired location, and press the Test button to test signal range.   

 

Proceed with mounting and installation once you are satisfied that UT-15 location functions properly. 

 

 

M

M

o

o

u

u

n

n

t

t

i

i

n

n

g

g

 

 

M

M

e

e

t

t

h

h

o

o

d

d

s

s

 

 

a

a

n

n

d

d

 

 

I

I

n

n

s

s

t

t

a

a

l

l

l

l

a

a

t

t

i

i

o

o

n

n

 

 

Step 1:    Find a suitable location for mounting. 

Step 2:  Mounting: 

(i)  Use the mounting holes on the transmitter  as a template  of  appropriate  hole 

positioning. 

(ii)  Use the provided wall plugs for plaster/brick installation.   

(iii)  Screw the transmitter into the provided wall plugs. 

< Note > 

 

Ensure the tamper switch spring is positioned so that it makes contact with the mounting 
surface through the tamper switch aperture. 

Step 3:  Put the Control Panel into (

Walk Test)

 Mode, and press the Test Button to test signal range 

Step 4:  Fit the white caps to the two mounting holes, installation is complete. 

 

Summary of Contents for UT-15SL

Page 1: ... and screw the Universal Transmitter directly onto the Door Frame or Wall covered by white caps 3 Tamper Switch Provides tamper protection against unauthorized device opening and or removal from mounting surface 4 Battery Insulator 5 Fixing Screw Screw used to secure the top and bottom case of the Universal Transmitter 6 Extension Terminal 1 Used for Door Contact IR Smoke Detector or Panic Button ...

Page 2: ...o receive a preset Device Contact signal the Control Panel will display the particular Device Contact is experiencing an out of signal problem G Ge et tt ti in ng g S St ta ar rt te ed d Remove the fixing screw and cover assembly Insert the CR2 3V battery into the battery holder connecting the polarity correctly Choose the type of connected device by sliding one Dip Switch on Universal Transmitter...

Page 3: ...nect the wired device to the extension terminal Step 4 Activate connected device to test signal transmission For multiple device wiring refer to diagram below N C N O U Us si in ng g t th he e E Ex xt te en ns si io on n T Te er rm mi in na al l 2 2 C CO ON N5 5 The Extension Terminal 2 can be triggered by the rotations of the axle Connect the roller sutter to Extension Terminal 2 to use this func...

Page 4: ...is connected Consult the dealer or an experienced radio TV technician for help FCC Caution To assure continued compliance any changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate this equipment Example use only shielded interface cables when connecting to computer or peripheral devices FCC Radiation Exposure Statement Th...

Reviews: