2
mounting surface (see
Mounting Tag Reader
for details).
When Tag Reader’s tamper is triggered, a tamper signal will be sent to the Control Panel for the
Control Panel to display the status. Once the signal is sent, Tag Reader returns to power saving
mode.
Getting Started:
Step 1.
Remove the cover by losing the fixing screw.
Step 2.
Power on the Tag Reader (see
Power
for details).
Step 3.
Adding Tag Reader into the Control Panel:
(a) Put Control Panel into Learning Mode (Refer to the operation manual of your Control Panel
for details), then Remove the Tag Reader’s cover.
(b) Press the Learn Button, Tag Reader will emit a beep and its info will display in the Control
Panel.
(c) Press the Add button, the Control Panel will send acknowledgement back to Tag Reader
and it will emit 3 beeps to indicate successful learning.
(c) If the Add button is not pressed within 10 seconds, Tag Reader will transmit a failed signal
with Red LED flashing 5 times. Please press the Learn Button again to learn into the
Control Panel.
Step 4.
Navigate the Control Panel into “
Walk Test
” mode. Hold the Tag Reader in the desired
location, and put the tag near Tag Reader tag sensor with 1 beep sound, to confirm this
location is within signal range of the Control Panel, if success the Tag Reader will emit 3
beeps.
Step 5.
When you are satisfied that the Tag Reader works in the chosen location, you can proceed
to mount the Tag Reader by following the below steps.
Mounting Tag Reader:
The Tag Reader consists of a two-part design made up of a cover and base. The cover contains all
the electronics and the base provides a mean of fixing. The tamper switch protects the enclosure
from being opened or being removed from the mounting surface.
The base has three knockouts for mounting purpose. To mount the Tag Reader:
I. Remove the fixing screw at the bottom
II. Remove the cover assembly
III. Break through the appropriate knockouts on the
mounting holes.
IV. Use the Mounting holes of the base as a template,
drill holes in the surface.
V. Insert the wall plugs if fixing into plaster or brick
VI. Screw the base into the wall plugs
VII. Fix the cover with the screw and clips to the base
<NOTE>
If the mounted Tag Reader is forcedly removed,
the Breakaway Area will be left on the wall
separated from the Tag Reader, the tamper will
then be triggered (only available by using the
Mounting Holes
method).
When connecting with an AC Adapter through the power terminal, pull the two-wired power
adapter through the power terminal hole before using the Tag Reader.
Tag Learning
After first power on the Tag Reader, please wait for 10 seconds for Tag Reader to enable tag sensor
function.
Please start learning the tag into the Control Panel, follow the steps as below: