
5
CONTENTS OF THE SUPPLY
General
The fan coil comes in a pack protected by a cardboard box
and is accompanied by:
• Installation manual
• Additional condensate tray
which are enclosed in plastic bags inside the indoor unit
pack.
• Air grille is provided in its own packaging
The operating and installation manual are considered
part of the appliance and must therefore be read careful-
ly and kept for reference.
RECEIVING AND HANDLING THE PRODUCT
General
The fan coils come in single packs protected by a cardboard
box.
It is advisable to remove the packaging only when the
appliance has been located near the point of installation.
After the packaging has been removed, the fan coil must
be handled manually by suitably equipped, qualified per-
sonnel and in compliance with accidentprevention
norms.
The fan coil must be handled by equipped qualified per-
sonnel using suitable equipment for the weight of the
appliance.
Take care when removing the adhesive strips from the
appliance.
Packaging components must be disposed of correctly
and not left within reach of children since they are a
potential source of danger.
PROJECT SPECIFICATIONS
General
PROJECT SPECIFICATIONS CHD U-2T
Frame in galvanised steel insulated with self-extinguishing
closed-cell polyethylene blanket of suitable thickness to limit
heat loss and noise to a minimum. Airflow grille in PS. Man-
ual louvers as well independent adjustable for vertical air-
flow direction. All the main parts can be easily accessed
through the grille. Regenerative air filters. Accident-preven-
tion grille over the fan intake.
Coil with corrugated aluminium fins and copper pipes, 100%
tested with dried air at 14 bar. 4-speed electric motor inclu-
sive of thermal switch. Low-rev radial-blade fan to maximise
acoustic comfort. Hydraulic connections. Manual air valve
with outlet connected to the condensate collecting tray.
Plastic condensate collecting tray housing the condensate
drain pump and float. Condensate drain pump with 650 mm
working head and 24 dB(A) noise level. Float for conden-
sate drain pump operation control and to warn of overflow
obstruction. Switchboard with power and control terminal
block with screw terminals.
Set-up for fresh air intake. Set-up for duct air distribution.
Set-up for cladding of air outlets. Ceiling-mounting brackets.
Hydronic cassette universal version connected with wall-
mounted thermostat.
PROJECT SPECIFICATIONS CHD U-4T
Frame in galvanised steel insulated with self-extinguishing
closed-cell polyethylene blanket of suitable thickness to limit
heat loss and noise to a minimum. Airflow grille in PS. Man-
ual louvers as well independent adjustable for vertical air-
flow direction. All the main parts can be easily accessed
through the grille. Regenerative air filters. Accident-preven-
tion grille over the fan intake.
Double coil for four pipe installation. Coils with corrugated
aluminium fins and copper pipes, 100% tested with dried air
at 14 bar. 4-speed electric motor inclusive of thermal switch.
Low-rev radial-blade fan to maximise acoustic comfort.
Hydraulic connections. Manual air valve with outlet connect-
ed to the condensate collecting tray. Plastic condensate col-
lecting tray housing the condensate drain pump and float.
Condensate drain pump with 650 mm working head and 24
dB(A) noise level. Float for condensate drain pump opera-
tion control and to warn of overflow obstruction. Switchboard
with power and control terminal block with screw terminals.
Set-up for fresh air intake. Set-up for duct air distribution.
Set-up for cladding of air outlets. Ceiling-mounting brackets.
Hydronic cassette universal version connected with wall-
mounted thermostat.
OPERATING LIMITS
General
Cassette fan-coil and heat exchanger:
• Maximum temperature of heat vector fluid = 80°C
• Minimum temperature of refrigerant fluid = 5°C
• Maximum working pressure = 8 bars
• Power supply voltage: 230V - 50Hz
• Electric energy consumption: see technical data label
Valves with thermoelectric actuator:
• Refer to instruction sheet present inside kit valve-unit.
Other technical data
All other important technical data (dimensions, weights, con-
nections, noise emissions, etc.) are given elsewhere in this
User and Installation manual.
Summary of Contents for CHD U-2T 1109
Page 6: ...6 UNIT DRAWINGS General CHD U 2T 506 706 CHD U 4T 506 706 CHD U 2T 809 1209 CHD U 4T 809 1209...
Page 17: ...17 ELECTRICAL CONNECTION Installation CHD 506 706 CHD 809 1209...
Page 35: ......
Page 36: ......
Page 37: ......