background image

7

PRE SET-UP INSTRUCTIONS

When choosing a location for the unit please follow 

guidelines below:

 

DO NOT:

•  DO NOT

 install near flammable gases.

•  DO NOT

 install near any source of heat, steam, or 

combustible gas.

•  DO NOT

 install anywhere where poisonous or sultry gases 

are generated.

•  DO NOT

 install in areas exposed to sea breezes.

•  DO NOT

 install near the doorway.

•  DO NOT

 install the indoor unit in a location subject to direct 

sunlight.

•  DO NOT

 install indoor unit near TVs or radios.

•  DO NOT

 kink the refrigerant line set.

•  DO NOT 

clean the air conditioner with excessive amounts 

of water.

•  DO NOT

 clean the air conditioner with combustible cleaning 

agents. Combustible cleaning agents can cause fire or 

deformation.

•  DO NOT

 operate the air conditioner with wet hands. This 

may cause electric shock.

•  DO NOT

 use device for any other purpose than its intended use.

•  DO NOT 

climb onto or place objects on top of the outdoor unit.

•  DO NOT

 allow the air conditioner to operate for long periods of 

time with doors or windows open, or if the humidity is very high.

•  DO NOT

 put the end of drain hose in water or a container that 

will collect water.

 CAUTION:

•  When drilling the wall hole for line set, make sure to avoid 

wires, plumbing, and other sensitive components.

•  This project requires 2 individuals for proper safety and 

practical installation Air conditioner body and remote 

controller must be (39-3/4”) or more away from a TV or a 

radio.

•  Ensure proper ventilation and avoid anything that may 

obstruct operation of the front of the indoor unit.

•  Choose a place which can stand the weight of the unit and 

does not increase the operation noise or vibration.

•  Avoid areas where there may be vibration in the house, and 

affix the unit by inserting / attaching vibration-proof pads 

between the unit and fittings.

•  Avoid leaving items near the outlet and inlet of the outdoor 

unit. These can cause malfunction or increase operation 

noise.

•  Contact ClimateRight® Customer Service if you hear irregular 

sounds during operation.

•  Only use a soft, dry cloth to wipe the unit clean. If the unit is 

especially dirty, you can use a cloth soaked in warm water to 

wipe it clean

•  Do not install the indoor unit on non-metal frame. Use 

mounting bracket provided.

INSTALLATION 

OF INDOOR UNIT  

Before installing the indoor unit, refer to the label on the 

product box to make sure that the model number of the indoor 

unit matches the model number of the outdoor unit.

CHOOSE AN APPROPRIATE LOCATION 

The following are standards that will help you choose an 

appropriate location for the indoor unit.
Proper installation locations meet the following standards:
•  Good air circulation.
•  Convenient drainage.
•  Noise from the unit will not disturb other people.
•  Firm and solid—the location will not vibrate.
•  Strong enough to support the weight of the unit.
•  A location at least one meter from all other electrical devices 

(e.g., TV, radio, computer).

INDOOR UNIT MINIMUM SPACE 

REQUIREMENTS

(91" minimum for 

ceilings over 9 ft)

Ceiling

Floor

4" 

6" 

6" 

72" 

Figure 1: Minimum space requirements for indoor unit

REQUIREMENTS FOR WALL MOUNT 

INSTALLATION

•  Wall mount must be level to ensure unit will function 

properly. 

•  Screws should be placed in wall studs to ensure the mount 

will support the weight of the indoor unit. 

•  Do not use any bracket other than the one provided.
•  Make sure there are enough screws in the mount to support 

the weight of the unit.

•  If the wall is made of brick, concrete, or similar material, drill 

5mm-diameter (0.2in-diameter) holes in the wall and insert 

sleeve anchors. Then secure the mounting plate to the wall 

by tightening the screws directly into the sleeve anchors.

 

Summary of Contents for easyair CR12000SACH

Page 1: ...ORE ASSEMBLY AND USE Read and follow all safety rules and instructions before operating this equipment THIS PRODUCT IS INTENDED FOR HOUSEHOLD USE ONLY Please keep this manual for future reference OWNER S MANUAL INSTALLATION GUIDE Install without the need for an HVAC technician Do it y urself easyair ...

Page 2: ...EMA 5 15 Control Panel Temperature Display Only operates with remote Remote Control Infrared Remote Compressor Rotary Thermostat Digital Refrigerant R410a 800g Line Set is Pre charged Filter Included washable Noise Interior Unit 42 dB Exterior Unit 53 dB Capacity Cooling BTU 12 000 Dehumidification pts hour 1 25 Heating BTU 14 000 heat pump Approximate Max Enclosure Size 500 550 sq ft Well insulat...

Page 3: ...he plug for this unit is polarized with one blade wider than the other Do not force the plug into an electrical outlet Do not alter the plug in any way If the plug does not fit into the outlet reverse the plug If it still does not fit contact a qualified technician to install a proper outlet Do not use if the power cord is damaged or the connection to the wall outlet is loose Operate product only ...

Page 4: ... in the affected room It can cool and dehumidify the air completely automatically and also provide heat using a heat pump Air pulled by the fan enters through the grill of the front panel and passes through the filter which traps dust inside Air is then sent to the heat exchanger and is cooled dehumidified or re heated by the heat exchanger Heat removed from the air is then sent outside When the c...

Page 5: ...nction in SLEEP mode which will automatically adjust the temperature to maximize comfort during night time sleep To put the air conditioner into SLEEP mode press the SLEEP button on the remote until the symbol is pointing to SLEEP on the remote s display If the system is set to run using the cooling or dry modes the set temperature will automatically be raised by 1 degree every 60 minutes for a to...

Page 6: ...6 REMOTE CONTROLLER BUTTON DIAGRAM Turns off digital display on indoor unit LAMP button Indicates the selected air rate It works on three dimensional air flow model ...

Page 7: ...it by inserting attaching vibration proof pads between the unit and fittings Avoid leaving items near the outlet and inlet of the outdoor unit These can cause malfunction or increase operation noise Contact ClimateRight Customer Service if you hear irregular sounds during operation Only use a soft dry cloth to wipe the unit clean If the unit is especially dirty you can use a cloth soaked in warm w...

Page 8: ...ommodate piping to both the left and right See figure 2 below for different ways piping can be fixed Figure 3 provides measurements for hole placement for Rear Outlet and Left Rear Outlet configurations Make sure to use minimum 2 75 hole saw Figure 3 Rear and left rear hole placement measurements Indoor wall mount 2 5 2 5 1 5 1 5 2 75 2 75 Rear outlet Recommended Left Rear outlet Figure 2 Optional...

Page 9: ...extension to the end of drain hose before operating Wrap the extension connection point firmly with Teflon tape to ensure a good seal and to prevent leaks INCORRECT CORRECT Figure 5 Installation of drain hose 7 Carefully bend the line set downward routing them to either the left or right as needed to connect to the condenser portion of the unit outside 8 Click the 2 round plastic housings around t...

Page 10: ...e more secure and assist with keeping the unit level EXTREME WEATHER CONSIDERATIONS If the unit is exposed to heavy wind Install unit so that air outlet fan is at a 90 angle to the direction of the wind If needed build a barrier in front of the unit to protect it from extremely heavy winds If the unit is frequently exposed to heavy rain or snow Build a shelter above the unit it to protect it from ...

Page 11: ...d Gravel or sand under the base can keep the base more secure and assist with keeping the unit level Unit must be 12 away from the wall for proper airflow and servicing 10 WARNING Read all safety instructions on page 3 before installing outdoor unit Read all outdoor installation requirements DO NOT DO NOT install near an obstacle that will block air inlets and outlets DO NOT install near a public ...

Page 12: ... unit current 6 If connecting power to fixed wiring a switch or circuit breaker that disconnects all poles and has a contact separation of at least 1 8in 3mm must be incorporated in the fixed wiring Use an approved circuit breaker or switch 7 Only connect the unit to an individual branch circuit outlet Do no connect another appliance to that outlet 8 Make sure to properly ground the air conditione...

Page 13: ...lide the spade connector on the end of the black L1 wire into the L1 terminal and tighten Then slide the spade connector on the end of the white L2 wire into the L2 terminal and tighten 16 Route utility power cord and line set power cord through the strain relief and tighten with screw removed in Step 18 17 Reinstall panel on unit and tighten screw FINISH INSTALLATION 18 Once the condenser is secu...

Page 14: ...m remote controller 5 Cover both indoor and outdoor units to prevent dust buildup PRE SEASON INSPECTION 1 Check for damaged wires 2 Clean air filters 3 Check for leaks 4 Replace batteries in the remote controller 5 Make sure nothing is blocking all air inlets and outlets TROUBLESHOOTING WARNING If ANY of the following conditions occurs turn off your unit immediately The power cord is damaged or ab...

Page 15: ...nd during operation This is normal and is caused by refrigerant gas flowing through both indoor and outdoor units Low hissing sound when the system starts has just stopped running or is defrosting This noise is normal and is caused by the refrigerant gas stopping or changing direction Squeaking sound Normal expansion and contraction of plastic and metal parts caused by temperature changes during o...

Page 16: ...ods winds fires lightning accidents corrosive environments rust etc or other conditions beyond the control of the Company 6 Parts not supplied or designated by Company or damages resulting from their use 7 Products installed outside USA and Canada 8 Electricity or fuel costs or increases in electricity or fuel costs from any reason whatsoever including additional or unusual use of supplemental ele...

Page 17: ..._________________________________________ Date of Purchase___________________________________ Date of Installation__________________________________ Owners Name______________________________________ Address of Installation_______________________________ _______________________________ Installing Contractor_________________________________ Address_________________________________________ Phone No E...

Reviews: