Tranquility THW - 50 & 60Hz R410A - ClimateMaster Geothermal Heat Pumps - Rev.: 30 June, 2008B
2
MODEL NOMENCLATURE
WARNING!
To avoid the release of refrigerant into the
atmosphere, the refrigerant circuit of this unit must be
serviced only by technicians who meet local, state, and
federal proficiency requirements.
WARNING!
All refrigerant discharged from this unit must be
recovered WITHOUT EXCEPTION. Technicians must follow
industry accepted guidelines and all local, state, and federal
statutes for the recovery and disposal of refrigerants. If a
compressor is removed from this unit, refrigerant circuit oil will
remain in the compressor. To avoid leakage of compressor oil,
refrigerant lines of the compressor must be sealed after it is
removed.
CAUTION!
To avoid equipment damage, DO NOT use
these units as a source of heating or cooling during the
construction process. The mechanical components and
filters will quickly become clogged with construction dirt
and debris, which may cause system damage.
�
WARNING!
�
�
WARNING!
�
�
CAUTION!
�
Safety
Warnings, cautions and notices appear throughout this manual.
Read these items carefully before attempting any installation,
service or troubleshooting of the equipment.
DANGER: Indicates an immediate hazardous situation, which
if not avoided will result in death or serious injury. DANGER
labels on unit access panels must be observed.
WARNING: Indicates a potentially hazardous situation, which if
not avoided could result in death or serious injury.
CAUTION: Indicates a potentially hazardous situation or an
unsafe practice, which if not avoided could result in minor or
moderate injury or product or property damage.
NOTICE: Notification of installation, operation or maintenance
information, which is important, but which is not hazard-related.
T H W
A
0 0 8
Q
G
0 0 C S A S
1 2
3
4 5 6
7
8
9
10 11
12
13
14
15
TH = Tranquility High Temperature
Heating Only
Model Type
W = Water-To-Water
Configuration
Unit Size
008 (50Hz Only)
010 (50Hz & 60Hz)
Revision Level
A = Current
Voltage
Controls
0 = Residential Standard (Ultra Quiet)
Cabinet Insulation
Domestic Hot Water Heating Options
C = Copper Source & Braze Plate Load
Source & Load Water Coil Options
N = Cupro-nickel Source & Braze Plate Load
A = None
Hydronic Options
B = Load Pump W/Expansion Tank
S = Standard
0 = None
Paint Options
S = Stainless Steel & Pewter (Black)
012 (50Hz Only)
1 = 3-Way Valve
C = Load Pump & Source Pump(S)
W/Expansion Tanks
Q = Standard 50Hz
V = Standard 50Hz With VSFP
W = Standard 60Hz
Y = Standard 60Hz With VSFP
G = 208-230/60/1 (THW010 Only)
T = 200-220/50/1 (THW008-010 Only)
S = 380-420/50/3 (THW012 Only)
Rev.: 12 Nov, 2008B
�
WARNING!
�
WARNING! Units are shipped with R-410A (EarthPure®)
refrigerant. The EarthPure® Application and Service Manual
should be read and understood before attempting to service
refrigerant circuits with R-410A.