24
DHW Pump Power –
displays the power con-
sumption of the DHW pump in watts.
DHW Flow –
displays the DHW gpm fl ow rate.
Hot Water EWT –
displays the temperature of
the potable hot water entering the potable hot
water heat exchanger.
Hot Water LWT –
displays the temperature of
the potable hot water leaving the potable hot
water heat exchanger, returning to the iGate
Smart Tank.
– Refrigerant
Diagnostics
Discharge Pressure –
displays the refrigerant
discharge pressure.
Discharge Saturation –
displays the saturation
temperature of the refrigerant discharge pres-
sure.
Discharge
Temp
–
displays the temperature of
the compressor discharge line.
Suction Pressure –
displays the refrigerant suc-
tion pressure.
Suction Saturation –
displays the saturation
temperature of the refrigerant suction pres-
sure.
Suction
Temp
–
displays the temperature of
the compressor suction line.
Discharge Superheat –
displays the amount of
superheat at the discharge of the compressor.
Suction Superheat –
displays the amount of
superheat at the suction to the compressor.
Subcool
–
displays the amount of subcooling
at the liquid line.
Wtr Coil Liquid –
displays the temperature of
the refrigerant liquid line between the source
heat exchanger and the electronic expansion
valve.
Wtr Coil Vapor –
displays the temperature of
the refrigerant vapor line between the heat/
cool reversing valve and the source heat
exchanger.
Air Coil Liquid –
displays the temperature of