14
CONFIGURING THE IGATE
™
CONNECT THERMOSTAT
The fi rst step after installing the iGate
™
Connect
thermostat is to confi gure the settings for the
equipment being connected.
An access code is required to enter the
Installation Settings menu. The access code is
4795.
Thermostat Confi g
Aux Heat Option
Confi gures the thermostat for electric auxiliary
heat or no auxiliary heat (none).
Equipment
Capacity Confi guration
Min Heating Capacity
Confi gures the
minimum unit heating capacity. When the
space requires a heating capacity below this
setting the unit will cycle off . Range will
depend on unit model.
Max Heating Capacity
Confi gures the
maximum unit heating capacity. When the
space requires a heating capacity above this
setting the unit will call for auxiliary heat (if
applicable). Range will depend on unit model.
Min Heating Airfl ow
Confi gures the unit
airfl ow while operating at minimum capacity
in the heating mode. The installer may wish
to select a higher cfm than the nominal cfm
for this setting to ensure proper air movement
To confi gure the iGate
™
Connect thermostat:
From the Home screen,
press
MENU
.
Select
Settings
▶
Installation
.
Select
Thermostat Confi g
.
To confi gure equipment
on the iGate
™
Connect
thermostat:
From the Home screen,
press
MENU
.
Select
Settings
▶
Installation
.
Select
Equipment
.