Climate Technology Bonaire Cool Change Series Owner'S Manual Download Page 3

Integra

Owner’s Manual

Page 3

CONGRATULATIONS ON YOUR

We're delighted you've chosen a Bonaire Fresh Air Conditioner to cool your home. It is an air

conditioner we are very proud of. Designed and made in Australia by Climate Technologies,

an 100% Australian owned company, it embodies the latest advances in fresh air conditioning

technology in a stylish, compact cabinet. Your air conditioner includes the worId's first radio

frequency remote control allowing you to control your air conditioner without the need for

special wiring. This allows you the flexibility to move the comfort controller from room to room

to suit your needs. If you have more than one Bonaire Envirotech Series air conditioner it is

possible to operate all air conditioners from the one comfort controller.

COMFORT

Comfort is a combination of four major factors; air temperature, air quality and cleanliness, air

speed and humidity. Bonaire fresh air conditioning cools the air by a process of evaporation,

which is controlled by the humidity in the air, therefore your Bonaire will cool the air differently

every day of the year. Your Bonaire uses only 100% fresh outside air which is filtered, and

when cooling is also washed. You will immediately appreciate the benefit of this constant flow

of fresh air - with or without cooling. '(our Bonaire installer will have placed the outlets in such

a position that you will feel the air flow. These outlets are adjustable and you may wish to

change or redirect the air to suit yourself. There may be a few days per year when the

humidity is very high and the cooling effect of your Bonaire fresh air conditioner is reduced, on

these days experiment with the cooling, you may find it more comfortable to turn the cooling

off and leave the fan running.

INFORMATION

The information contained in the following pages has been prepared to ensure you enjoy

trouble free operation of your Bonaire Fresh Air Conditioner.

For additional sales assistance call your nearest Bonaire Branch on

 131257

‘Due to Bonaire’s policy of continuous product improvement, design and technical
specifications are subject to change without notice.’
E.&O.E.

Summary of Contents for Bonaire Cool Change Series

Page 1: ...Owner Manual ...

Page 2: ...rt Setting Fan Only Operation Cleaning the pads Setting the Timer Setting the Automatic Operating Periods Automatic Operation Overriding the Automatic Operation Power Supply Interruption 11 Configuring your Comfort Control 11 Unit Maintenance 12 Problem Solving 14 Warranty Statement 15 Manufactured by ABN 13 001 418 042 26 Nylex Avenue Salisbury SA 5108 Phone 08 8307 5100 Fax 08 82830401 In the in...

Page 3: ...vaporation which is controlled by the humidity in the air therefore your Bonaire will cool the air differently every day of the year Your Bonaire uses only 100 fresh outside air which is filtered and when cooling is also washed You will immediately appreciate the benefit of this constant flow of fresh air with or without cooling our Bonaire installer will have placed the outlets in such a position...

Page 4: ... page 4 2 TURNING THE UNIT ON Press the ON OFF button Your air conditioner will operate on your previous settings If your previous setting was cooling there may be a three minute pre cool delay 3 COOLING Press the COOL button to switch on or off the cooling 4 BOOST ON OFF Press the BOOST button to go to high fan immediately Press again and the fan will return to the original setting 5 TURNING THE ...

Page 5: ...ng that there be sufficient exhaust openings in the area to be ventilated Open doors and windows will usually provide this The minimum exhaust opening should be as per the table guide set out below It is recommended that ceiling vents or exhaust fans be used where there is any doubt about there being sufficient exhaust area available Ceiling exhaust fans or ceiling vents should have a capacity equ...

Page 6: ... Page 6 RADIO FREQUENCY REMOTE CONTROL LOCATION OF CONTROLS Access to your Controls To access AUTO MAN ECONOMY FRESH COOL PAD CLEAN or TIMER functions the control door has to be opened To open lift the right side of the door ...

Page 7: ...Integra Owner s Manual Page 7 RADIO FREQUENCY REMOTE CONTROL ...

Page 8: ...he pump fan only press the COOL button until FRESH is indicated AUTO MODE In this mode the air conditioner automatically controls the fan and pump settings All you need to set IS your desired comfort level To select the automatic operation press the MANUAL AUTO ECO button until AUTO is shown in the display In auto mode you can select your desired comfort level 12 graduated bars from LO TEMP to Hi ...

Page 9: ...Integra Owner s Manual Page 9 ...

Page 10: ...Integra Owner s Manual Page 10 ...

Page 11: ... pre cool start features ensures the filter pads are wet prior to starting the fan This means that after starting your air conditioner there may be a delay of up to 3 minutes before the fan starts During a pre cool start cycle the word PRE COOL flash In manual or economy mode operation if you have recently run your air conditioner on cooling or you start your air conditioner on FRESH there will no...

Page 12: ... is full of water DO NOT FORGET THE PUMP STRAINER Turn off the water inlet to the unit an Isolation Valve should be fitted to the water inlet before the Float Valve Drain the tank by removing the 40mm standpipe It may be necessary to repeat this procedure if the tank is very dirty SAFETY Wet roofs are dangerous Take Care When Draining Tank Water Level Float Valve The water level should be set at n...

Page 13: ...checked to ensure it is adequate and that there is no build up of mineral deposits in or on your air conditioner White deposits indicate high mineral content and the Bleed Rate should be increased If it is at maximum and the deposits are still forming then more regular maintenance is required Pump Check the pump spins freely and that the strainer is clean Water Distribution Check the water distrib...

Page 14: ...e as necessary Water Droplets in air stream c Pump Delivers Excessive Water to Pads c Adjust the Dialflo to reduce the flow a Inadequate Exhaust a Provide more open area to exhaust stale air Excessive humidity b Outside humidity high b Turn pump off a Dirty Filters a Clean b Dry Filters b Check water delivery system Adjust if necessary Inadequate Cooling c Dialflo not set correctly c Adjust dialfl...

Page 15: ...uments of purchase and Dealer Installer information will assist in this process A charge will be made for work or a service call where there is nothing wrong with the appliance or where the defective operation of the appliance is due to failure of electricity or water supply or where defects are caused by neglect incorrect application abuse or by accidental damage of the appliance or by an unautho...

Page 16: ...Integra Owner s Manual Page 16 ...

Reviews: