Multi-Appliance Touch Pad 

 

 
 

 
 

Multiple Unit Setup 

This instruction is for PNE touchpad controls connected to compatible Bonaire EAC and or 
Vulcan & Pyrox gas central heaters. 

The Bonaire EAC units compatible are fitted with the “2003S” control system. This will be 
indicated by the label on the control box inside the unit. The control box will also be Grey 
in colour. 

The Vulcan & Pyrox gas central heating units compatible are fitted with control boards 
that include an external reset button. 

  

CONNECTING ALL THE UNITS 

Step 1

 

Before connecting the comms looms, ensure the power is isolated to all the 
units being connected.  

Step 2 

Connect the touchpad to the first 
appliance using the PNE connection 
loom.  

Step 3

 

Connect all appliances together in a daisy 
chain effect using the PNE connection 
loom.   

For evaporative air conditioning, the 
control is fitted with a spare comms port.  
The comms ports are parallel connected 
on the control board, so there is no 
required sequence for connection on each 
control board. 

For ducted central heating, the control is 
only fitted with one comms port.  For 
multiple connections of central heaters, a 
home automation module will be required 
for each unit to be connected in the daisy 
chain. 

 

 

CODING THE UNITS 

Step 1

 

Turn the power on to the 1

st

 unit 

only connected to the touchpad. 
The unit will no auto-code itself 
to the touchpad.  This is 
indicated by the 4 dashes on the 
screen.

 

 

Step 2

 

Once the coding process has complete,  
turn the unit on to verify the coding has 
completed itself correctly. 

Step 3 

Turn the power on to the next unit to code 
and allocate the code / zone required.  

See next section for coding and allocation 
of additional units.

 

Evaporative Cooler 

Board 

Central Heater 

Board 