EVAPORATIVE AIR COOLER CM-18000 

 

www.climateplus.ae 

 
 

 
MAINTENANCE 
 

For best results and long term operation, regular 
maintenance is essential. 

 
Remove the filter pad by unscrewing the 4 screws on the rear of the cooler, then lift the pad 
and pull out at the bottom to release. To replace the pad slide up into the slot under the top of 
the cooler, push in at the bottom and allow dropping into the lower slot. 
 
Clean the pad from the inner-side to out-side of pad (inner side is towards motor). Never use 
any liquid detergent. Never use pressurized water, as it may cause damage to the pad. 
 
3) Unscrew the drainage lid to let dirty water flow out, then clean the water tank thoroughly 
with a soft cloth. Wash off dirt on the water sensor, water pump and the float valve. Rinse 
thoroughly. 
 
Use mild soft clean cloth when cleaning the cooler casing. Do not use any caustic chemical 
detergent that may cause damage to the surface of the cooler. 
 
To prevent buildup of algae and biological organisms in the reservoir, regularly add 
chlorine/bromine tablets as per tablet manufacturer recommendation of evaporative cooler 
reservoirs. 

 

 

 

 

 

 

 

 

 

-07

 

Summary of Contents for CM-18000

Page 1: ...EVAPORATIVE AIR COOLER CM 18000 www climateplus ae...

Page 2: ...used supplied as standard a float valve keeps the reservoir full continuously If filled manually the big 60 Litre capacity reservoir ensures hours of uninterrupted operation There is a digital level i...

Page 3: ...Dimension L W H mm 1120x700x1650 Weight kg 63 Effective Cooling Area m2 100 150 TECHNICAL FEATURE New evaporative cooling pad energy levels fan speed low medium high saving and environmentally friend...

Page 4: ...power immediately and refer to dealer for service D Other tips for cooler use 1 Keep doors and windows open to allow fresh air to enter and treated air to exit when cooler is operating 2 Flashing red...

Page 5: ...EVAPORATIVE AIR COOLER CM 18000 www climateplus ae KEY COMPONENTS 04...

Page 6: ...When COOL is pressed again the water evaporation feature is turned off with only the fan operating SPEED Pressing SPEED will select low medium or high fan speed SWING This activates deactivates swing...

Page 7: ...EVAPORATIVE AIR COOLER CM 18000 www climateplus ae CONTROL PANNEL REMOTE CONTROLLER 06...

Page 8: ...nner side is towards motor Never use any liquid detergent Never use pressurized water as it may cause damage to the pad 3 Unscrew the drainage lid to let dirty water flow out then clean the water tank...

Page 9: ...inner side is towards motor Never use any liquid detergent Never use pressurized water as it may cause damage to the pad 3 Unscrew the drainage lid to let dirty water flow out then clean the water ta...

Page 10: ...is nothing preventing free rotation of the fan Clean the cooling pad and dust filter Change the fan Change the main control board Motor does not respond to control panel Main control board failure Pan...

Reviews: