CLIMASTAR SMART TOUCH 1000 Installation Manual And User'S Manual Download Page 6

6

 

 

 

The appliance must be installed in such a way that switches 
and other control devices cannot be touched by a person 
using a bath or shower.  

 

The installation must be carried out in accordance with the 
current electrical regulations.  

 

The heater is fitted with a flexible cable size 3 x 1.00 mm2 
for electrical connection. It may be used to connect the 
heater to the fixed wiring of the premised through a suitable 
connection box positioned adjacent to the heater.  

 

The supply circuit to the heater must incorporate a double 
pole isolating switch having a contact separation of at least 
3 mm.  

 

If the flexible supply cord is damaged, it must be replaced 
by a repair workshop recognised by the manufacturer, in 
order to avoid hazard.  

 

All models are supplied with an electrical interrupt cut-out. 
This will switch off the heater if, for any reason, it 
overheats. Should the cut-out operate, turn the heater off 
and remove the cause for the overheating. The cut-out will 
be reset automatically.  

 

The presence in the air of particles of smoke, dust and other 
pollutants could, in time, discolour the walls and surfaces 
around the heater. 

 

 

 

Summary of Contents for SMART TOUCH 1000

Page 1: ...INSTALLATION MANUAL AND USER GUIDE SMART TOUCH RANGES...

Page 2: ...2...

Page 3: ...ARTING THE DEVICE 8 3 2 SETTING DATE AND TIME 8 3 3 MANUAL MODE 8 3 4 AUTOMATIC MODE 9 3 5 PILOT WIRING MODE 10 3 6 COPY FUNCTION 10 3 7 KEY BLOCK FUCTION 11 3 8 SOUND FUNCTION 11 3 9 OTHER INFORMATIO...

Page 4: ...pliance Cleaning and user maintenance must not be made by children without supervision Children aged from 3 years and less than 8 years shall only switch on off the appliance provided that it has been...

Page 5: ...supply to which connection is to be made WARNING In order to avoid overheating do not cover the heater Do not use this heater to dry clothes The air outlet at the top of the thermal radiator and the a...

Page 6: ...ater The supply circuit to the heater must incorporate a double pole isolating switch having a contact separation of at least 3 mm If the flexible supply cord is damaged it must be replaced by a repai...

Page 7: ...e radiator and any inflammable material as furniture curtains etc Recommended clearances required to maintain are indicated on the following figure Once decided the location to install the device remo...

Page 8: ...to validate press OK Date and time are now set Press ESC and select the comfort temperature pressing the arrows Your device is now working 3 3 MANUAL MODE In this mode the device works as per factory...

Page 9: ...O ECO 05 H ECO ECO ECO ECO ECO ECO ECO 06 H ON ON ON ON ON ECO ECO 07 H ON ON ON ON ON ON ON 08 H ECO ECO ECO ECO ECO ON ON 09 H ECO ECO ECO ECO ECO ON ON 10 H ECO ECO ECO ECO ECO ON ON 11 H ON ON ON...

Page 10: ...ess Ok to validate E Go on programming the remaining hours until 23 00 h at this stage the display shows the day to programme If we want to set the remaining days turn to B if not press 3 5 PILOT WIRI...

Page 11: ...If we are in the main menu and the device is not being manipulated it will turn to stand by mode and the display will only show a dot Touch any button to redisplay the main menu To turn on the screen...

Page 12: ...should be vacuumed because dust can be accumulated in the heating element while the time of the year that the radiator is been off Do not use solvents or abrasive products for cleaning After the heati...

Page 13: ...ICAL Power W 800 Size mm 1000 x 500 x 70 Weight Kg 22 Voltage V 230 V Frequency Hz 50 Hz Ceramic component DUAL KHERR External Housing Powder coated steel structure Plug On request THERMOSTAT Features...

Page 14: ...switch in position I Program is OFF Check that the set program is the chosen one or set the one you desire The radiator stains the walls Radiator located at a very low height The minimum height from...

Page 15: ...on and poor electricity supply to the system This warranty is also excluded if it is used with another purpose other than heating for an alteration modification tampering or unauthorized repairing of...

Page 16: ...handed over to the applicable collection point for the recycling of electrical and electronic equipment By ensuring this product is disposed of correctly you will help prevent potential negative conse...