TROUBLESHOOTING 

 

 

 
ERROR CODES 

 

Error-detecting code 

Multi-functional defection 

E1 

Error of the coil’s temperature sensor 

E2 

Error of indoor temperature sensor 

E4 

Anti-freezing  protection:  temperature  of  the  coil  is  too  low  and 
the  whole  A/C  is  off.  When  temperature  excesses  8

,  the 

protection is released and previous working state is recovered. 

 
 
If any other error codes are displayed please contact the following via email

 [email protected] 

 
 
 
TECHNICAL SUPPORT / CUSTOMER SERVICE CONTACT 
 

If you require Technical Support or Customer Service please contact us in the following way: - 
 
Email: [email protected] 
Telephone: 01273 803820 
 
 
 
 
 
 
 

PROBLEM

 

POSSIBLE CAUSE 

REMEDY 

Unit does not 
operate or only runs 
in fan mode.

 

Is the unit plugged in? 

Securely plug the power cord into the wall 
outlet. 

Is the main power supply on? 

Re-establish the main power supply.   

Is the water container full indicator light 
on? 

Empty the water container. 

Is the timer set? 

Change timer settings. 

Cooling efficiency is 
not satisfactory. 
 

 

Is the air inlet or outlet blocked? 

Clear the blocking.

 

Is there any other heat source in the 
room? 

Move the heat source. 

Are the air filters dirty? 

Clean the air filters. 

Is the temperature setting suitable? 

Change the temperature setting.   

Is the fan speed set at low? 

Increase the fan speed. 

Auto power off in 
Heating Mode 

Heating Protection, when the 
temperature at the air outlet exceeds 
70C, the unit will power off 
automatically 

Restart the unit at lower room temeprature 

Unit is noisy or 
vibrates.

 

Is the machine positioned unevenly on 
a level surface?

 

Place the unit on a level surface.

 

The unit starts and 
stops frequently.

 

Is the voltage from the power source 
correct?

 

Use a proper power source. 

 

Is the exhaust hose positioned 
incorrectly? 

Position the exhaust hose correctly and 
keep the exhaust hose straight as 
possible. 

Summary of Contents for PAC12K

Page 1: ...r Conditioner and Heater With Heat Pump Technology PAC12K 12 000btu Cool Heat Portable Air Conditioner Please read this manual carefully prior to operating the product Please keep ALL packaging for duration of Warranty Period ...

Page 2: ...ammable spray on the unit 6 Confirm drainage piping is connected properly 7 Do not start or stop the unit by inserting or pulling out the power plug 8 Do not operate with wet hands 9 Close supervision is necessary when the unit is used near children The unit in not intended for use by children 10 Do not insert anything into the air outlet Do not obstruct air inlet or outlet grills 11 Do not expose...

Page 3: ...ician for repair or maintenance of this unit 28 Unplug the unit if strange sounds smell or smoke comes from it General Information Recycling This marking indicates that this product should not be disposed with other household wastes throughout the EU To prevent possible harm to the environment or human health from uncontrolled waste disposal recycle it responsibly to promote the sustainable reuse ...

Page 4: ...______________________ Invoice Number _______________________________________________________ WARRANTY This product comes with a 12month warranty from date of purchase as indicated on original sales receipt Please note that it is a warranty condition that ALL of the original packaging is kept for the duration of the warranty period the main box can be folded flat for storage If you need to make a ...

Page 5: ... DIAGRAM 1 Handle 2 Air inlet L 3 Control panel 4 Wind guide bar 5 Caster 6 Remote controller 7 Air inlet R 8 Air outlet 9 Dehumidification drainage nozzle 10 Air inlet grille 11 Exhaust hose set 12 Window kit ...

Page 6: ...temperature press it at timing mode to adjust timing ON OFF time press Up and Down keys simultaneously to switch Fahrenheit and Centigrade degree temperature 5 Mode key Press the key to choose cooling fan dehumidification and heating mode 6 Timer key Press the key at standby mode to set ON time Press this key at ON mode to set OFF time 7 Temperature time display window This window displays the adj...

Page 7: ...he opening at the back of the air conditioner Venting the Exhaust Air The exhaust hose should be kept as short and straight as possible so as to not restrict airflow of the exhausted air There are 3 x options with venting the exhaust air 1 You can make a hole in the wall and pass the exhaust hose through the hole in the wall this option doesn t require a window to be slightly open 2 You can pass t...

Page 8: ...l of the window kit if necessary 2 Place the window kit between the window and the window frame as shown in the images to the right Close the window onto the window kit to form a tight seal 3 Attach the exhaust duct adapter to the window kit Tabs located on the adapter will lock into place securing the adapter to the window kit Incorrect installation It s important to keep the exhaust duct smooth ...

Page 9: ... key or choosing Fan mode by pressing the remote controller the wind indicator lamp lights up Press Speed key to choose High Mid Low speed Temperature can t be set Dehumidification mode When pressing mode key or choosing dehumidification mode by pressing the remote controller the dehumidification indicator lamp lights up Remove the dehumidification water wedge insert water manifold place the other...

Page 10: ...roduct is equipped with automatic water vaporization system The condenser is cooled with the circulating of condensing water so as to improve cooling efficiency and save energy If the internal vessel is full of water the display screen will display FL and the compressor stops working automatically After power off unscrew the water cover pull out the water wedge to drain off water and it will becom...

Page 11: ... very dirty use a neutral detergent in lukewarm water and dry in the shade Put air filter back into unit close the air inlet grille Wash the filter screen once every two weeks If it is blocked by dust efficiency of the A C will be reduced Take out the air inlet grille and pull out the filter screen at both sides according to the direction shown in the following figures Put the filter screen into t...

Page 12: ...ply on Re establish the main power supply Is the water container full indicator light on Empty the water container Is the timer set Change timer settings Cooling efficiency is not satisfactory Is the air inlet or outlet blocked Clear the blocking Is there any other heat source in the room Move the heat source Are the air filters dirty Clean the air filters Is the temperature setting suitable Chang...

Page 13: ...oor area of the room shall be mentioned in the form of a table or a single figure without reference to a formula A warning to keep any required ventilation openings clear of obstruction A notice that servicing shall be performed only as recommended by the manufacturer A warning that ducts connected to an appliance shall not contain a potential ignition source When the portable air conditioner or d...

Page 14: ...erant gas used CAUTION ON FIRE READ THE MAUAL CAREFULLY BEFORE USING THE APPLIANCE R290 refrigerant gas complies with European environmental directives This appliance contains approximately 245 g of R290 refrigerant gas Appliance shall be installed operated and stored in a room with a floor area larger than 12 m2 ...

Page 15: ...h involves exposing any pipe work shall use any sources of ignition in such a manner that it may lead to the risk of fire or explosion All possible ignition sources including cigarette smoking should be kept sufficiently far away from the site of installation repairing removing and disposal during which refrigerant can possibly be released to the surrounding space Prior to work taking place the ar...

Page 16: ...es shall be disconnected from the equipment being worked upon prior to any removal of sealed covers etc If it is absolutely necessary to have an electrical supply to equipment during servicing then a permanently operating form of leak detection shall be located at the most critical point to warn of a potentially hazardous situation Particular attention shall be paid to the following to ensure that...

Page 17: ...rigerants refrigerants purging shall be achieved by breaking the vacuum in the system with oxygen free nitrogen and continuing to fill until the working pressure is achieved then venting to atmosphere and finally pulling down to a vacuum This process shall be repeated until no refrigerant is within the system When the final oxygen free nitrogen charge is used the system shall be vented down to atm...

Page 18: ... charged into another refrigerating system unless it has been cleaned and checked 17 LABELLING Equipment shall be labelled stating that it has been de commissioned and emptied of refrigerant The label shall be dated and signed For appliances containing flammable refrigerants ensure that there are labels on the equipment stating the equipment contains flammable refrigerant 18 RECOVERY When removing...

Page 19: ...ompressors or compressor oils are to be removed ensure that they have been evacuated to an acceptable level to make certain that flammable refrigerant does not remain within the lubricant The evacuation process shall be carried out prior to returning the compressor to the suppliers Only electric heating to the compressor body shall be employed to accelerate this process When oil is drained from a ...

Reviews: