ClimaCheck GSM Modem Manual – 2015-02-26 7(22)
Check the
UDP send active
box to start sending data. Uncheck the box if you want to
disable the sending of data.
Click
Update
to confirm your changes.
Figure 4
3.5
Setting Gateway
The last step to enable sending of data is to set the Gateway in the Modem/PPP section.
Choose
Settings -> Connection -> Modem/PPP
.
Copy the number from the
IP-address
field to the
Gateway
field. The default IP-
address/Gateway is
192.168.48.95
.
If you want to disable sending change
Gateway
back to
0.0.0.0
Click
Update
to confirm your changes.
Click
Restart
to restart with the new settings enabled.
The PA Pro will now use the connected modem to send data to the server using GPRS and UDP.
Figure 5
Important!
If the PA Pro has been configured with a Gateway setting other than 0.0.0.0 on the
LAN/DNS tab to communicate over a local network, the Modem connection will not work