4
46
6
© 2005 Directed Electronics—all rights reserved
1
1--8
8 FFO
OR
RCCEED
D P
PA
ASSSSIIV
VEE A
AR
RM
MIIN
NG
G O
ON
N//OFF:: To use this feature, passive arming must be selected in Feature 1-1. When
turned on, forced passive arming will ensure that the system will passively arm, even if a zone is left open or
invalid. Forced passive arming occurs one hour after the ignition is turned off.
1
1--9
9 A
AU
UTTO
OM
MA
ATTIICC EEN
NG
GIIN
NEE D
DIISSA
AB
BLLEE ((A
AEED
D)) ON//O
OFFFF: AED is a full-time, passive starter disable that works independ-
ently of the security system. When turned on, the orange, ground-when-armed output (H1/1) will activate 30
seconds after the ignition is turned off. The LED will flash at half its normal rate when the ignition is turned off
to indicate that AED is active and will interrupt the starter in 30 seconds. AED does not occur in Valet mode and
can be bypassed using the emergency override procedure. The transmitter can be used to disarm AED, however,
the system must be armed and then disarmed, using the transmitter, to disarm AED.
1
1--1
10
0 A
AR
RM
MEED
D W
WH
HIILLEE D
DR
RIIV
VIIN
NG
G ((A
AW
WD
D)) O
ON
N//OFF:: In the default setting (Armed While Driving), the system can be
armed with the ignition on. When armed, the ground-when-armed is not active and the sensors are bypassed.
The door triggers will remain active.
1
1--1
11
1 CCO
OD
DEE H
HO
OP
PP
PIIN
NG
G®
® O
ON
N//O
OFFFF:: The system uses a mathematical formula to change its code each time the trans-
mitter and receiver communicate. This makes the group of bits or "word" from the transmitter very long. The
longer the word is, the easier it is to block its transmission to the unit. Disabling the Code Hopping® feature lets
the receiver ignore the Code Hopping® part of the transmitted word. As a result, the unit may have better range
with Code Hopping® off.
1
1--1
12
2 H
HO
OR
RN
N O
OU
UTTP
PU
UTT P
PU
ULLSSEED
D//CONSTANT:: Program for either a pulsed output or a continuous output when trig-
gered.
1
1--1
13
3 H
HO
OR
RN
N FFU
UN
NCCTTIIO
ON
N ((FFU
ULLLL A
ALLA
AR
RM
M O
ON
NLLY
Y))//SIREN FUNCTION (20mS, 30mS, 40mS, 50mS): Program for output
when the alarm is fully triggered or as the siren (arming/disarming and warnaway and full trigger with timing
options).
1
1--1
14
4 CCO
OM
MFFO
OR
RTT CCLLO
OSSU
UR
REE—
—ON,, O
OFFFF:: The system can be programmed to close the windows when the system is armed.
A 20-second output starts 200mS after the last lock pulse. The Comfort Closure output will be canceled if the unlock
button is pressed. If programmed ON, the lock output wire provides this function.
2
2--1
1 SSIIR
REEN
N D
DU
UR
RA
ATTIIO
ON
N 3
30
0//60 SSEECCO
ON
ND
DSS:: It is possible to program the unit to sound for 30 or 60 seconds
during the triggered sequence. Some states have laws regulating how long a security system can sound.
When using the Bitwriter®, the siren can be programmed to sound for any length of time from 1 second to 180
seconds.
m
meennuu ##22 -- aaddvvaanncceedd ffeeaattuurreess