Page 1: ...2003 Directed Electronics Inc Vista CA N909600 4 03 installation guide...

Page 2: ...uitry NPC Revenger Silent Mode Soft Chirp Stinger Valet Vehicle Recovery System VRS and Warn Away are all Trademarks or Registered Trademarks of Directed Electronics Inc Vista California I IM MP PO OR...

Page 3: ...nnector 18 mounting the receiver antenna19 arming disarming diagnostics 20 arming 20 disarming 20 system status chirps 20 remote siren silencing 21 multiple event total recall 21 table of zones 21 sys...

Page 4: ...ith harness z One 518C Neo Siren z One 18 pin main wiring harness z One four pin immobilizer harness z One 6 pin secondary harness z One Owner s Guide z Two window decals z Warranty registration card...

Page 5: ...pond to a standard configuration transmitter standard configuration Button The arming disarming and panic function are controlled by this button Button The trunk release or accessory output A is contr...

Page 6: ...on Output 30 WHITE Light Flash Output WHITE Light Flash Output WHITE RED Light Flash Input BROWN Speaker Output 2 RED 12V Constant GREEN Door Trigger Input Zone 4 VIOLET Door Trigger Input Zone 4 BLUE...

Page 7: ...onnect the BLACK wire to a clean paint free sheet metal location driver s kick panel using a factory bolt that does NOT have any vehicle component grounds attached to it A screw should only be used in...

Page 8: ...5 It can also be used with Directed single stage sensors h1 8 violet door trigger input zone 4 Connect the violet wire to a wire that shows 12V when any door is opened This wire will report Zone 4 h1...

Page 9: ...confirm light flash polarity before connecting H1 12 or damage to the vehicle lighting system could occur h1 15 black white dome light supervision output Connect the H1 15 BLACK WHITE wire to the vehi...

Page 10: ...t 87 This wire determines the output of the BLACK WHITE H1 15 wire on the main 18 pin harness If the vehicle has a negative domelight circuit ground this wire if the vehi cle has a positive domelight...

Page 11: ...in or removing the jumper located next to the immobilizer wires exiting the module immobilizer jumper setting jumper in setting When the jumper is in the ignition and starter signal will bypass the U...

Page 12: ...wires that pulse 12 volt alter nately on lock and unlock make sure that it is not a Type C direct wire system Cut the wire that pulses 12 volt on lock and then operate the switch to unlock z If all d...

Page 13: ...se locking are high current so a 451M or 2 relays need to be used The switch will have three wires on it and one wire will test ground all the time One wire will pulse negative when the switch locks t...

Page 14: ...res The switch that lost all operation is the master switch If one switch works in both directions and the other switch works in only one direction you have a Type A system If both switches still oper...

Page 15: ...ed Vehicles without factory power door locks require the installation of one actuator per door This requires mounting the door lock actua tor inside the door Other vehicles may only require one actuat...

Page 16: ...from the passenger key cylinder If all the doors lock the vehicle s door lock system can be controlled with just two relays optional The control wire can be found in either kick panel and will show 1...

Page 17: ...cutting the wire to lock the door In some vehicles these functions are reversed Type F door locks are found in late model Nissan Sentras some Nissan 240SX and Nissan 300ZX 1992 up They are also found...

Page 18: ...relays or a DEI 451M must be used Single Resistor Type If one resistor is used in the door lock switch key cylinder the wire will pulse 12 volt in one direction and less than 12 volt when operated in...

Page 19: ...relays or a DEI 451M must be used Single Resistor Type If one resistor is used in the door lock switch key cylinder the wire will pulse ground in one direction and resistance to ground when operated i...

Page 20: ...the back of a panel drill a mounting hole using a 17 64 inch drill bit Be sure to check for clearance prior to drilling the mounting hole plain view valet The Valet Program switch should be accessible...

Page 21: ...eceiver antenna is centered high on either the front or rear windshield For optimal range the antenna should be mounted vertically It can be mounted horizontally in relation to the windshield or under...

Page 22: ...ones section of this guide disarming If a zone is triggered three disarm chirps will sound The specific zone that was trig gered is then reported by the LED when the ignition is turned on For more zon...

Page 23: ...rigger and proceed down to the eighth trigger If fewer than eight triggers are stored in memory the LED will blink continuously until the system is armed disarmed or the ignition is turned on For more...

Page 24: ...g with a mouse This eliminates the need for programming grids and lengthy programming sequences For a complete guide to system programming using the Cliffnet Wizard Pro refer to the Cliffnet Wizard he...

Page 25: ...ew 2 Valet switch The siren will chirp three times to indicate programming mode has been exited user selectable features This feature is only available with optional IntelliStart connected This featur...

Page 26: ...n arming disarming the system but at a lower volume than normal auto lock ignition off rpm z Ignition The doors will automatically lock three seconds after the ignition is turned on unless a door is o...

Page 27: ...ass for 60 minutes zones that are triggered three times within a one hour period z Off The alarm will respond to zone inputs indefinitely without bypassing remote valet on off z On The alarm can be pu...

Page 28: ...ree The features in this column pertain to programming individual transmitter channels in custom configurations Following is an explanation of the features Program the indi vidual transmitter channels...

Page 29: ...ol z This feature is only available with SmartWindows connected z The transmitter channel programmed into this feature will activate the vent or roll down feature of the SmartWindows system clear all...

Page 30: ...ntered the feature selection posi tion of the Installer Selectable Features grid P1 Pulsed channel output is disabled with the ignition on or the alarm is armed P2 Pulsed channel output works anytime...

Page 31: ...uto testing will generate a warning to indicate the door is open accessory output b auto activation N NO OT TE E The accessory output will not auto activate if programmed to latched setting z Off z Ar...

Page 32: ...en the ignition is turned on one time valet on off z On Allows one time valet mode feature z Off Does not allow one time valet mode feature accessory output a timer duration z Start Timer Press the ar...

Page 33: ...the wait to start input wires N NO OT TE E RPM must be reprogrammed after changing this feature smart windows program z This feature applies only if SmartWindows is installed z Enter this feature and...

Page 34: ...figuration an arm dis arm channel must first be programmed before programming the remaining channels Note 3 Selecting siren sounds After entering this feature press the arm disarm button The siren wil...

Page 35: ...4 Wait for two siren chirps after a five second pause or five seconds after the last digit has been entered if using less than four digit code number 5 Turn off the ignition the siren will chirp three...

Page 36: ...0 minute time period expiring without attempted trig gers or the ignition to be turned on and off This allows the system to be repeatedly trig gered disarmed and rearmed and still allow FACT II to byp...

Page 37: ...ot trigger the sensor since it is designed to react to multiple closely grouped sounds A sharp rap with a set of keys should trig ger the sensor If the sensitivity needs to be increased turn the adjus...

Page 38: ...s the arm disarm button of the transmitter z Arm the alarm and then disarm the alarm z Turn the ignition on and enter the system valet PIN code one time valet feature This feature allows the system to...

Page 39: ...the wrong door input has been used The system will not passively arm until it is remotely armed and then disarmed z Are the door inputs connected Is a BLUE wire connected to the door trigger wire in t...

Page 40: ...www directed com 38 wiring reference guide...

Page 41: ...2003 directed electronics inc 39 TM TM RF Report Mux Sensor Port Shock or Proximity Sensor Port CliffNet Wizard Port Smart Self Powered Siren Power 18 Pin Harness LED Port PlainView 2 Valet Port...

Page 42: ...40 TM TM Immobilizer Harness Immobilizer Jumper RF Report Mux Sensor Port Shock or Proximity Sensor Port CliffNet Wizard Port Smart Self Powered Siren Power 6 Pin Harness 18 Pin Harness LED Port Plain...