WWW.CLF-LIGHTING.COM
11
Onboard control menus
Main Menu
2nd Menu
3rd Menu
Notes
DMX ADDRESS
DMX ADD
1-512
set DMX address
02CH
Dimmer, Color temperature
Control mode
03CH
Dimmer, Color Temperature, Strobe Default
05CH
Dimmer, Dimmerfine, Color
temperature, Preset CCT, Strobe
Dimmer Speed
Normal / Smooth 1 / Smooth 2 /
Smooth 3 / Smooth 4
Default: Normal
Dimmer Curve
Linear / Square law / INV Square/
S-curve / Special
Default: Linear
Calibration
Normal / Factory
Default: Factory
Personality
Refresh rate
600-5000Hz
Default: 1200Hz
DMX hold
DMX hold / No DMX hold
Default: DMX hold
KEY-LOCK
ON / OFF
Default: OFF
Knobs
Brightness & CCT / Function OFF
Default: Brightness & CCT
Fixed Color
CW, CW / WW / WW
Static Color
CCT
3200K ~ 6000K
Default: 4000K
Dimmer
0-225
Strobe
0-20
Software version
V1.00
Used Time
Total: xxxxxH
LED Total: xxxxxH
Info
Temperature
Current temperature: xxx°C
Max. temperature: xxx°C
Min. temperature: xxx°C
RDM-UID
0xxxxxxx
Error message
Cold
Hot
Error
Factory Reset
Load factory default
YES / NO
Use ‘Up’ and ‘Down’ button to select your desired operation, press ‘Enter’ to set all functions
Notes:
•
When there’s a flickering ‘!’ sign appeared, means no signal input for the fixture.
•
No operation within 30 seconds, LCD display will enter into Screen of mode automatic.
•
When the current temperature is higher than the protection temperature, 30% of power
consumption will be deducted slowly.