CLF Colour Par 12 Manual Download Page 13

13

04 channels

Channel

1

2

3

4

Value

000~255

000~255

000~255

000~255

Description

Red

Green

Blue

Dimming

03 channels

Channel

1

2

3

Value

000~255

000~255

000~255

Description

Red

Green

Blue

Master/Slave Control Mode

1

Setting master machine

Acc

ess control panel function by pressing 

MENU

 until 

AUTO

 is displayed.

Press ENTER, select 

ATXX

 OR

PRXX

 by pressing UP/DOWN buttons.

Press ENTER, and then press 

MENU

 to exit.

You can choose 

ATXX

pre-set programs, the range is 

o1--10

.

you can choose 

PRXX

custom programs, the range is 

o1--10

2

Setting slave machine

Access contro

l panel function by pressing 

MENU

 until 

RUN

 is displayed.

Press ENTER, press UP/DOWN buttons until the

SLAV

 is displayed.

Press 

MENU

 return to MENU

3

Usage of Master/Slave

When two

 or more fixtures connected, you can set up the first machine as the 

Master and the followed fixtures as Slaves. The Master can choose pre-set programs ...

ATXX

OR

PRXX

 

, all the slaves will follow the Master's operation synchronously.

Summary of Contents for Colour Par 12

Page 1: ...1 CLF Colour Par 12 CLF Colour Par 12 CLF Colour Par 12 CLF Manuals CLF Manuals Version 1 0 November 2012 Version 1 0 November 2012 ...

Page 2: ...e must be returned to the factory it is important that the fixture be returned in the original factory box and packing AC POWER This fixture has an auto switching switch mode power supply that can accommodate a wide range of input voltages The only thing necessary to do before powering on the unit is to make sure the line voltage you are applying is within the range of accepted voltages This fixtu...

Page 3: ...echnician Make sure that the working voltage will not higher or lower than the rated value Make sure that the cable didn t be damage or lacerated by sharp The light must be power off when it s standing idle or before clearing The cable must with plug and you must pull out the cable by handle the plug Please be careful when installing the lighting Never touch the bared cable or it will cause the de...

Page 4: ...t Size 295x 195 x255mm l Package Size 350x260x320 mm l N W 4 6Kg l G W 5 6Kg Features l RGB color mixing with or without DMX controller l 5 distinct dimming curves l LED display with password protection l Operating Modes DMX512 Connection Master Slave l DMX Channels 03CH 04CH 05CH 06CH 06 channels Dimmer RGB Macro AUTO strobe 05 channels RGB Dimmer strobe 04 channels RGB Dimmer 03 channels RGB ...

Page 5: ...5 Product Overview Hanging bracket floor stand Bracket adjustment knob Power in Power out DMX IN DMX OUT Control board Dimensions ...

Page 6: ...nging it and make sure the weight of the light is within limits of the hanger l Please make sure without any flammable objects within 0 5m when installing the light l The installation should be operated by professional person any irregular installation will cause the body injury or equipment damage l Block access below the work area and use suitable and stable platform when installing or servicing...

Page 7: ...hen proceed to connect from the output as stated above to the input of the following fixture and so on 3 This product can be connected numerous lamps in series without the need for the signal amplifier the signal will not be weakened DMX IN DMXOUT DMX IN DMXOUT DMX IN DMXOUT 3 PIN TO 5 PIN CONVERSION CHART Note If you use a controller with a 5 pin DMX output connector you will need to use a 5 pin ...

Page 8: ...menu list and decreases the numeric value when in a function Navigates upwards through the menu list and increases the numeric value when in a function Enables the currently displayed menu or sets the currently selected value in to the selected function 4 OPERATING INSTRUCTIONS Control Panel Functions 8 MENU ...

Page 9: ...the operatingmode for thefixture to receive signal froma DMX controller DMX receive signalor Download programs from Masterfixture Slave 03 channels RGB 04 channels Dimmer RGB 05 channels Dimmer RGB Strobe 06 channels Dimmer RGB Off meansselect linear dimming or choose dimmer 1 4to control thedimming speed dimming 1of the fastestdimming curves 4 forthe most slowlydimming curve Reset factory default...

Page 10: ...n for the S is the rate of strobe T is the operating time of the present step the value is between 0 to 255 F is the transitional time from previous step to present step The transitional time is the quickest when the FADE is 0 Notice Please operate the program in turn from the 01st step to the 30th step When the operating program less than 30 steps please set the final step value be 0 4 Repeat ste...

Page 11: ...EN DOWN Purple BLUE100 RED UP Red RED100 BLUE DOWN Yellow RED100 GREEN UP Lime GREEN100 BLUE80 RED78 Green GREEN100 RED blue DOWN Teal GREEN 10 BLUE 10 Cyan GREEN UP BLUE UP Colour Scroll Snap Speed 1 Fastest Colour Scroll Snap Speed 2 Colour Scroll Snap Speed 3 Colour Scroll Snap Speed 4 Colour Scroll Snap Speed 5 Colour Scroll Snap Speed 6 Colour Scroll Snap Speed 7 Colour Scroll Snap Speed 8 Co...

Page 12: ...ed 3 Colour Scroll FADE Speed 4 Colour Scroll FADE Speed 5 Colour Scroll FADE Speed 6 Colour Scroll FADE Speed 7 Colour Scroll FADE Speed 8 Colour Scroll FADE Speed 9 Colour Scroll FADE Speed 10 Colour Scroll FADE Speed 11 Colour Scroll FADE Speed 12 Colour Scroll FADE Speed 13 Colour Scroll FADE Speed 14 Colour Scroll FADE Speed 15 Colour Scroll FADE Speed 16 Colour Scroll FADE Speed 17 Slowest S...

Page 13: ...NTER and then press MENU to exit You can choose ATXX pre set programs the range is o1 10 you can choose PRXX custom programs the range is o1 10 2 Setting slave machine Access control panel function by pressing MENU until RUN is displayed Press ENTER press UP DOWN buttons until the SLAV is displayed Press MENU return to MENU 3 Usage of Master Slave When two or more fixtures connected you can set up...

Page 14: ...ion Thisdoes not mean that allof the LEDshave failed butthe circuit iswired in series Note In the event of LED failure a replacement LED PCB assembly may be purchased directly from Our company Check total load placed on the electrical circuit Check for a short in the electrical wiring internal and or external Check for power on Mains Note In the event of autoswitching transformer failure the unit ...

Page 15: ...le Solution s Make sure connector is firmly connected to device This fixture must be in the correct mode in order to properly respond to the COLOR CON controller The correct mode is DMX in the onboard Control Panel This fixture has built in automatic programs that may be triggered from the onboard Control Board ...

Page 16: ...al core PCB assembly Power supply seat XLR seat LED Driver Board House Bracket Assembly Bracket adjustment metal knob Display PCB assembly Electronic Transformer Part Number 6P00118 6P00105 2P00106 5100103 5100102 2P00107 6P00118 5120117 5020105 2P00103 5080125 Blow out Diagram ...

Reviews: