background image

WWW.CLF-LIGHTING.COM

7

Physical installation

Warning! The fixture must be either fastened to a flat surface such as a stage or wall, or clamped to a truss or
similar structure in any orientation using a rigging clamp.

 

Warning! If the fixture can cause injury or damage if it falls, attach an approved safety cable to one of the safety cable
attachment points on the base (see “Fixture overview”).

Check that all surfaces to be illuminated are minimum 200 mm. from the fixture, that combustible materials
(wood, fabric, paper, etc.) are minimum 100 mm. from the fixture, that there is free airflow around the fixture
and that there are no flammable materials nearby.

 

Fastening the fixture to a flat surface

The

 fixture can be fastened to a fixed flat surface that is oriented at any angle. Check that the surface can

support at least 10 times the weight of all fixtures and equipment to be installed on it.

Warning! The supporting surface must be hard and flat or cooling may be blocked, which will cause overheating.
Fasten the fixture securely. Do not stand it on a surface or leave it where it can be moved or can fall over. Attach a
securely anchored safety cable to the safety cable attachment point (see “Fixture overview”) if the fixture is
to be installed in any location where it may fall and cause injury or damage if the primary attachment fails.

1. Block access under the work area. Working from a stable platform, hang the fixture on the truss with the
    arrow on the base towards the area to be illuminated. Tighten the rigging clamp.
2. Secure the fixture against clamp failure with a secondary attachment such as an approved safety cable
    that is rated for the weight of the fixture using one of the attachment points at the edges of the base (see
    “Fixture overview”). Do not use any other part of the fixture as a safety cable attachment point.
3. Do not connect more than two fixtures vertically

Summary of Contents for LED FAN XL

Page 1: ...manual WWW CLF LIGHTING COM V1 0 NOVEMBER 2018 led fan xl ...

Page 2: ...for reliable data transmission 6 Physical installation 7 Fastening the fixture to a flat surface 7 Outdoor IP rated fixtures 8 Condensation moisture inside housing 8 Fixtures temperature specification 8 Setup 9 Control panel and menu navigation 9 DMX address setting 9 Control mode 10 Onboard control menus 11 DMX protocol 12 Exploded view 13 Specifications 14 WWW CLF LIGHTING COM ...

Page 3: ...Dimensions All dimensions are in millimeters WWW CLF LIGHTING COM 1 1000mm 1000mm 100mm ...

Page 4: ...y please contact your supplier PROTECTION FROM ELECTRIC SHOCK Disconnect the fixture from AC power before removing or installing any cover or part and when not in use Always ground earth the fixture electrically Use only a source of AC power that complies with local building and electrical codes and has both overload and ground fault earth fault protection Before using the fixture check that all p...

Page 5: ... of the fixture without protective eyewear such as shade 4 5 welding goggles At less than this distance the LED emission can cause eye injury or irritation At distances of 3 meters and above light output is harmless to the naked eye provided that the eye s natural aversion response is not overcome Do not look at LEDs with magnifiers telescopes binoculars or similar optical instruments that may con...

Page 6: ...OM 4 Fixture overview FRONT SIDE SIDE BACK BOTTOM TOP SAFETY CABLE ATTACHMENT POINTS ATTACHMENT POINTS G HOOK ART NO 520113 or 520114 OMEGA BRACKET ART NO 875760 POWER OUT DMX OUT POWER IN DMX IN DISPLAY CONTROL BUTTONS ...

Page 7: ...ng Socket outlets or external power switches used to supply the fixture with power must be located near the fixture and easily accessible so that the fixtures can easily be disconnected from power Important Do not insert or remove live PowerCON TRUE 1 connectors to apply or cut power as this may cause arcing at the terminals that will damage the connectors Important Do not use an external dimming ...

Page 8: ...e 2 Connect the DMX output of the fixture closest to the controller to the DMX input of the next fixture and continue connecting fixtures output to input Relaying power to other devices Warning Do not connect more than six fixtures in total to AC mains power in one interconnected chain Power can be relayed to another device via the PowerCON TRUE 1 throughput socket If you daisy chain the fixtures ...

Page 9: ...of all fixtures and equipment to be installed on it Warning The supporting surface must be hard and flat or cooling may be blocked which will cause overheating Fasten the fixture securely Do not stand it on a surface or leave it where it can be moved or can fall over Attach a securely anchored safety cable to the safety cable attachment point see Fixture overview if the fixture is to be installed ...

Page 10: ...atively affected after long term UV exposure and should be checked by qualified service technicians over time Tighten screws too hard will also affect the IP rating solid object Moisture IP Ingress Protection 2 0 Protected against a solid object greater than 50mm such as a hand Protected against a solid object greater than 12 5mm such as a finger Protected against a solid object greater than 2 5mm...

Page 11: ...ion press ENTER To escape a function or move back one level in the menu structure press MODE DMX address setting The DMX address also known as the start channel is the first channel used to receive instructions from the controller For independent control each fixture must be assigned its to a separate channel The DMX address can be configured by using the DMX ADDRESS menu in the control panel For ...

Page 12: ...OM 10 Control mode DMX control mode is selected in the CONTROL MODE menu The fixture can be controlled with 2 DMX control modes 5ch 11ch RGB group 1 RGB group 2 Master dimmer Color macro Macro speed Strobe Motor rotating ...

Page 13: ... color RGB PART 1 RED 0 100 Select static color and rotation status GREEN 0 100 BLUE 0 100 RGB PART 2 RED 0 100 GREEN 0 100 BLUE 0 100 Rotation 0 255 5 Personality Testing Yes No Select testing function Dimmer Speed Slow Normal Calibration RED 100 255 GREEN 100 255 BLUE 100 255 DMX hold On Off Backlight display On Off Display rotate On Off 6 Info Software version Show software version Error Show e...

Page 14: ...w to fast 10 Strobe 000 010 Strobe open 011 250 Strobe from slow to fast 251 255 Strobe open 11 Motor Rotating 001 127 0 360 degree positioning 128 180 CW rotating from slow to fast 181 191 Stop 192 250 CCW rotating from slow to fast 251 255 Stop NO Channel 5 DMX value Functions Remark 1 Master Dimmer 000 512 Master dimming 0 100 2 Color Macro 000 010 No function 011 150 Static colors 151 255 Colo...

Page 15: ...frame CLF 80 011 2 Plastic front cover CLF 80 008 8 Metal support bracket motor CLF 80 012 3 LED board CLF 80 005 9 Timing belt CLF 80 003 4 Metal support bracket LED board CLF 80 013 10 Step motor CLF 80 002 5 Main display PCB CLF 80 007 11 Complete central rotating part CLF 80 009 6 Power supply CLF 80 006 1 2 3 4 5 6 7 8 9 10 11 ...

Page 16: ...wer plug type PowerCON True Configuration LED color RGB Quantity of LED 1206 pcs Dimming frequency 4000Hz Dimmer resolution 16 bit Optical Beam angle 125 Photometric Output 1M 1525 lux Output 5M 64 lux Heat management Cooling type Connection cooling MAX ambient temp Ta max 40 C MIN ambient temp Ta min 20 C Menu Auto program YES Static color YES Manual calibration YES Factory calibration NO Strobe ...

Page 17: ...d 5pin in out Hardware Interface Full color LCD display Software upload method Via PCB Installation IP rating IP20 Housing Safety attachment point YES Physical Net product weight 29Kg Machine dimensions length 1000mm Machine dimensions depth 100mm Machine dimensions height 1000mm Accessories Included items Powercable manual Approvals Approved certifications CE RoHs ...

Page 18: ...WWW CLF LIGHTING COM CLFLIGHTING led fan xl ...

Reviews: