CLF Lighting EF Smoke 1500 Manual Download Page 8

WWW.CLF-LIGHTING.COM

8

menu navigation

Press MENU button to navigate different setting pages.

1. 

DMX address setting page

When it shows ADDR, press ENTER button to enter into the setting page of DMX address. Press UP or DOWN to increase or decrease 

the address value. After finished setting, press ENTER button again to back to page ADDR.

2. 

DMX address setting page

When it shows “CH-1” , press ENTER button to set LED color under button one. Through UP and DOWN button, user can realize the 

color setting. After finished setting, press ENTER again to exit to page CH-1. The LED’s color could be set to OFF, 9 colors (Co1-Co9) 

and change color automatically (rand).

1. 

When set to OFF, the LED would not light up. 

2. 

9 colors are as following:

• Co 1:  Red  

 

 

• Co 6:  Orange

• Co 2:  Green 

 

 

• Co 7:  Yellow

• Co 3:  Blue 

 

 

• Co 8:  Sky blue

• Co 4:  Pink  

 

 

• Co 9:  White

• Co 5:  Purple 

 

 

After setting the above color, the LED will show the corresponding color when press the button A on the remote (CH-1 matches with 

button A). Under Random mode, the LED will change color freely, the interval is 1.

 

Note: 

 Under DMX control, the LED’s color would be controlled by DMX controller instead of this color setting page.

There are four color standby modes, namely CH-1, CH-2, CH-3 and CH-4. Different channels match with different button on the wireless 

remote.

3. 

Wireless remote setting

When it shows REMO, press ENTER button to set wireless remote function.

Press UP button, it will show ON. This means that the wireless control function is activated, and it will show the registering page when 

the machine is powered on. Press DOWN button, it will be OFF. This means that the wireless control function is shut off. And it will not 

show the wireless remote registering page when the machine is powered on. After setting, press ENTER button again to exit to page 

REMO.

4. 

No-fluid protection setting page

When it shows OIL, press ENTER button to set the status of low-fluid protection. Press UP button, it will show ON. This means that the 

low-fluid protection function is activated. Press DOWN button, it will be OFF. This means that low-fluid protection function is shut off. 

After setting, press ENTER button again to exit to page OIL.

This machine supports wireless remote control, DMX control, fluid sensor, stop immediate function and LED lights (3W LED, 32 in total). 

DMX control is prior to wireless remote control. Fog duration is about 7S.

1. 

LED lights are controlled by the digital display and DMX.

2. 

LED lights instruction

3. 

Under wireless remote control, LED color is set according to the digital display. The LED’s on/off synchronize with the Fog’s on/off.

4. 

Under DMX control, fog and LED are separate. It has 7 channels to control the effects of LED lights. Please refer to below DMX 

instruction for the details.

Summary of Contents for EF Smoke 1500

Page 1: ...manual V1 0 APRIL 2018 WWW CLF LIGHTING COM ef smoke 1500 ...

Page 2: ...LIGHTING COM 2 Machine overview 3 Safety instruction 4 AC power 6 Data link 6 Physical installation 7 Operating instructions 7 Menu navigation 8 DMX channels 9 Maintenance 10 Specifications 11 table of CONTENTS ...

Page 3: ...id tube 2 Tank fixing plate 3 32 pcs LED 4 Ventilation 5 Power switch 6 Overload protection 7 PowerCON 8 2 5L tank 9 Nozzle 10 3 pin DMX socket 11 LCD display 12 Direct fog button 13 5 pin DMX socket 14 Ventilation inlet 15 Handle 16 Safety point ...

Page 4: ... supplier PROTECTION FROM ELECTRIC SHOCK Disconnect the machine from AC power before removing or installing any cover or part and when not in use Always ground earth the fixture electrically Use only a source of AC power that complies with local building and electrical codes and has both overload and ground fault earth fault protection Before using the machine check that all power distribution equ...

Page 5: ...onnect any other type of device to these sockets Do not stick filters masks or other materials onto any optical component Do not modify the machine in any way not described in this manual Do not connect machine to a dimmer PROTECTION FROM INJURY Ensure that persons are not looking at the LEDs from within 3 meters when the product lights up suddenly This can happen when power is applied when the pr...

Page 6: ...r s instructions Table 1 shows standard wire color coding schemes and some possible pin identification schemes if pins are not clearly identified or if you have any doubts Wire color EU models Wire color US models Conductor Symbol Screw US Brown Black Live L Yellow or Brass Blue White Neutral N Silver Yellow green Green Ground earth Green Table 1 Wire color coding and power connections or data lin...

Page 7: ...e base see machine overview on page 4 Do not use any other part of the machine as a safety cable attachment point operating instructions 1 After checking that all the parts are intact and complete position the machine on a flat surface 2 Only use designated CLF Lighting smoke liquid Machine can be harmed when using other fluids and warranty is expired 3 Connecting the power cord Before power on ma...

Page 8: ...on the wireless remote 3 Wireless remote setting When it shows REMO press ENTER button to set wireless remote function Press UP button it will show ON This means that the wireless control function is activated and it will show the registering page when the machine is powered on Press DOWN button it will be OFF This means that the wireless control function is shut off And it will not show the wirel...

Page 9: ...9 OFF CH 2 LED red output 010 255 0 100 000 009 OFF CH 3 LED green output 010 255 0 100 000 009 OFF CH 4 LED green output 010 255 0 100 000 009 OFF CH 5 Color Macro 010 255 0 100 000 009 OFF CH 6 Random Color 010 255 0 100 000 009 OFF CH 7 LED strobe 010 255 0 100 000 009 OFF CH 8 Dimmer 010 255 0 100 000 009 OFF ...

Page 10: ... will appear the terminal symptom of heater blocking 1 heater blocked is because used inferior fog fluid or not maintenance for a long time Have nothing to do with the quality of machine Like a car with poor quality gasoline produce poor oil circuit failure or long time no maintenance the car will inevitably appear bigger problems fig 2 Solutions to these problems Fog machine heating pipes used fo...

Page 11: ...N max 6 8m height and max 8 sec Settings and addressing control panel with 7 digit screen Protocol USITT DMX512 A Wireless Color Black Housing High strenght die casting aluminium and metal Protection rating IP20 Orientation Up and downwards when fuel tank is rotated Min distance to combustable materials 100mm from machine Min distance to iluminated surfaces 200mm from machine Wireless remote 4 but...

Page 12: ...WWW CLF LIGHTING COM CLFLIGHTING ef smoke 1500 ...