6

Connect your speaker systems via the speaker terminals (COM = -VE) 

Examples: 1) COM + 4-16Ω

 

   2) COM + 70V

 

   3) COM + 100V

Note: Please do not use more than one pair of output terminals 

Connections To The Mains

Before connecting the amplifier to the local mains voltage outlet should be checked to ensure the 

available supply is 240V~AC 50Hz. This product is CLASS1 and requires a protective mains earth 

to be connected at all times. DO NOT remove or disconnect the earth.

Power On/Off Procedure

After connecting your amplifier to the mains, turn all controls counter clockwise to the “min” 

position. Turn on audio sources (MP3 players, CD players, Microphones etc) before powering the 

amplifier ON. The last product to be switched on is the amplifier.

If you wish to power off the system, turn the amplifier’s master volume control counter clockwise 

to the “min” position before switching the amplifier OFF before any audio sources are switched off. 

By following this procedure it will prevent acoustic shocks to the speakers or potential damage to 

system components. 

Machine operation

1. After connecting all audio source and powering on the power amplifier, adjust the and the 

master volume.

2. The Clever Acoustics amplifier features output signal LED with PEAK indication. Should the 

PEAK indicator illuminate (flashing) the output of the amplifier is too high, turn the master volume 

anti-clockwise to reduce the output.

3. The Clever Acoustics amplifier all features protection with LED indication. Should the  

PROTECT indicator illuminate, turn the master volume control anti-clockwise fully and switch off 

the amplifier for 15 seconds as the amplifier may have entered PROTECT mode temporarily due 

to a peak signal, care should then be taken to ensure all input levels are set correctly. If the  

amplifier persists to enter PROTECT mode the amplifier should be switched off and left to cool 

for 5-10 minutes before switching back on. If the PROTECT indicator remains lit this indicates a 

problem with the amplifier or amplifier load (ie Short Circuit).

4. Speaker & Amplifier systems can produce high sound pressure levels, please operate all 

controls with caution to ensure people are not exposed to excessive or dangerous sound pressure 

levels. 

Summary of Contents for SL 4120

Page 1: ...4120 4 CHANNEL AMPLIFIER POWER TEMP ON OFF 5 0 1 2 3 4 6 7 8 9 10 5 0 1 2 3 4 6 7 8 9 10 5 0 1 2 3 4 6 7 8 9 10 5 0 1 2 3 4 6 7 8 9 10 CH1 CH2 CH3 CH4 PROTECT SIGNAL CLIP SL 4240 4 CHANNEL AMPLIFIER U...

Page 2: ...ollow the instructions of this manual CAUTION TAKE CARE USING THIS EQUIPMENT HIGH VOLTAGE RISK OF ELECTRIC SHOCK Before your initial start up please make sure that there is no damage caused during tra...

Page 3: ...uipment and the power cable periodically If the equipment is dropped or damaged disconnect the mains power supply immediately Have a qualified engineer inspect the equipment before operating again If...

Page 4: ...suit multi zone applications in schools offices and stores Features Four separate amplifiers in a single 19 rackmount chassis 70V 100V and 4 16 loudspeaker outputs Balanced XLR line input for each cha...

Page 5: ...W T8AL 250V 4 SL 4240 SL 4120 1 6 12 12 11 10 6 2 3 8 7 4 9 5 SL 4120 SL 4240 POWER TEMP ON OFF 5 0 1 2 3 4 6 7 8 9 10 5 0 1 2 3 4 6 7 8 9 10 5 0 1 2 3 4 6 7 8 9 10 5 0 1 2 3 4 6 7 8 9 10 CH1 CH2 CH3...

Page 6: ...mode Switch off the amplifier and check the output connections for faults or short circuits before powering on and resuming operation 4 CLIP LED This LED will flash when the output signal starts to di...

Page 7: ...ential damage to system components Machine operation 1 After connecting all audio source and powering on the power amplifier adjust the and the master volume 2 The Clever Acoustics amplifier features...

Page 8: ...LE ENABLE REMOTE WALL CONTROL DISABLE ENABLE REMOTE WALL CONTROL REMOTE SOURCE 8 300mV 1 1V 10K 300mV 1 1V 10K 300mV 1 1V 10K 300mV 1 1V 10K 300mV 1 1V 10K 300mV 1 1V 10K 300mV 1 1V 10K 300mV 1 1V 10K...

Page 9: ...or the fuse Maintenance and service operations are only to be carried out by authorised dealers Replacing the fuse Only replace the fuse by a fuse of the same type and rating Before replacing the fuse...

Page 10: ...www cleveracoustics co uk...