Clever Acoustics SL 4120 User Manual Download Page 6

5

Rack Installation

The SL Series are rack mountable. The rack you use should be a double door rack where you can 

open the front and rear panel. When mounting the amplifier into the rack, please make sure that 

there is enough space around the amplifier for the clear flow of cool air and the exhaust of hot air.

Be careful when mounting the amplifier into the rack. Put the heaviest products into the lower part 

of the rack. Be aware that fastening the amplifier with four screws on the front panel is not  

sufficient to absorb impact from road transit vibrations, additional support may be required.

Inputs

Short cables runs improve the sound quality remarkably. Input cables should be short and direct, 

since high frequencies will mostly be absorbed if the cables are unnecessarily long. Besides that 

a longer cable may lead to humming and noise problems. If the cable runs are unavoidable, you 

should use balanced cables.

Outputs

The high damping factor of your amplifier supplies a clear sound reproduction. Unnecessarily long 

and thin cables used for low impedance (4-16Ω) speakers will influence the damping factor and 

thus the low frequencies in a negative way.

Identification:

  1. Power LED - 

This LED will illuminate once the amplifier is switched on and is ready for use.

  2. TEMP LED - 

Temperature LED will illuminate when overheating. Switch off the amplifier  

      and leave to cool down.

  

3. PROT LED -

 This LED will illuminate when the unit goes into protect mode. Switch off the  

      amplifier and check the output connections for faults or short circuits before powering on and  

      resuming operation.

  

4. CLIP LED - 

This LED will flash when the output signal starts to distort. At this point turn the 

      master volume anti-clockwise to prevent damage.

  5. SIGNAL LED - 

This LED will light up when signal is being received .

  6. Fan vent

 - Do not obstruct, keep clear of dust.

  7. On/off power switch - 

Use the switch to power the unit on or off.

  8. CH1 volume control - 

Use this control to increase or decrease the volume of channel 1.

  9. CH2 volume control - 

Use this control to increase or decrease the volume of channel 2.

10. CH3 volume control - 

Use this control to increase or decrease the volume of channel 3.

11. CH4 volume control - 

Use this control to increase or decrease the volume of channel 4.

12. Carry handles

13. Fan vent

 - Do not obstruct, keep clear of dust.

14. Power input -

 240V 50Hz.

15. Mains fuse - 

If the mains fuse requires replacement, use the same type and value as  

      originally supplied.

16. CH1 loudspeaker output terminals - 

Connectors for 4-16

 or 70V and 100V speakers.

17. CH2 loudspeaker output terminals - 

Connectors for 4-16

 or 70V and 100V speakers.

18. CH3 loudspeaker output terminals - 

Connectors for 4-16

 or 70V and 100V speakers.

19. CH4 loudspeaker output terminals - 

Connectors for 4-16

 or 70V and 100V speakers.

20. CH1 XLR signal input -

 Use this to connect signal input from mixer amplifiers.

21. CH2 XLR signal input -

 Use this to connect signal input from mixer amplifiers.

22. CH3 XLR signal input -

 Use this to connect signal input from mixer amplifiers.

23. CH4 XLR signal input -

 Use this to connect signal input from mixer amplifiers.

Summary of Contents for SL 4120

Page 1: ...4120 4 CHANNEL AMPLIFIER POWER TEMP ON OFF 5 0 1 2 3 4 6 7 8 9 10 5 0 1 2 3 4 6 7 8 9 10 5 0 1 2 3 4 6 7 8 9 10 5 0 1 2 3 4 6 7 8 9 10 CH1 CH2 CH3 CH4 PROTECT SIGNAL CLIP SL 4240 4 CHANNEL AMPLIFIER U...

Page 2: ...ollow the instructions of this manual CAUTION TAKE CARE USING THIS EQUIPMENT HIGH VOLTAGE RISK OF ELECTRIC SHOCK Before your initial start up please make sure that there is no damage caused during tra...

Page 3: ...uipment and the power cable periodically If the equipment is dropped or damaged disconnect the mains power supply immediately Have a qualified engineer inspect the equipment before operating again If...

Page 4: ...suit multi zone applications in schools offices and stores Features Four separate amplifiers in a single 19 rackmount chassis 70V 100V and 4 16 loudspeaker outputs Balanced XLR line input for each cha...

Page 5: ...W T8AL 250V 4 SL 4240 SL 4120 1 6 12 12 11 10 6 2 3 8 7 4 9 5 SL 4120 SL 4240 POWER TEMP ON OFF 5 0 1 2 3 4 6 7 8 9 10 5 0 1 2 3 4 6 7 8 9 10 5 0 1 2 3 4 6 7 8 9 10 5 0 1 2 3 4 6 7 8 9 10 CH1 CH2 CH3...

Page 6: ...mode Switch off the amplifier and check the output connections for faults or short circuits before powering on and resuming operation 4 CLIP LED This LED will flash when the output signal starts to di...

Page 7: ...ential damage to system components Machine operation 1 After connecting all audio source and powering on the power amplifier adjust the and the master volume 2 The Clever Acoustics amplifier features...

Page 8: ...LE ENABLE REMOTE WALL CONTROL DISABLE ENABLE REMOTE WALL CONTROL REMOTE SOURCE 8 300mV 1 1V 10K 300mV 1 1V 10K 300mV 1 1V 10K 300mV 1 1V 10K 300mV 1 1V 10K 300mV 1 1V 10K 300mV 1 1V 10K 300mV 1 1V 10K...

Page 9: ...or the fuse Maintenance and service operations are only to be carried out by authorised dealers Replacing the fuse Only replace the fuse by a fuse of the same type and rating Before replacing the fuse...

Page 10: ...www cleveracoustics co uk...

Reviews: