Clever Acoustics MA 4060MP User Manual Download Page 6

www.cleveracoustics.co.uk

4 Zone Mixer Amplifier series

  

User Manual

6

Operation instructions

Initial Start Up Procedure

•  

Reset all “Level” or “Volume” controls to the “0” position on the front panel. Reset the BASS and TREBLE  

   

controls to the centre point.

•  

Reset CH1 thru CH5 gain controls & TEL level control on the rear panel to the “0” position.

•  

Connect the audio sources & mains power input.

•  

Switch on the amplifier using the mains switch on the front panel. The LED indicator (13) will illuminate  

   

BLUE if the amplifier is ready for use and working correctly, if the indicator illuminates RED this indicates  

   

the amplifier is under PROTECT status.

•  

Adjust CH1 thru CH5 gain controls to match the input signal levels between different sources

CH1 to CH5 Operation (note: CH1 thru CH5 feature the same operation)
1) 

BASS control:

 BASS control offers tonal adjustment for the low frequency, turn  

   

clockwise to increase and anti-clockwise to decrease.

2) 

TREBLE control:

 TREBLE control offers tonal adjustment for the high frequency, turn  

   

clockwise to increase and anti-clockwise to decrease.

3) 

VOLUME (LEVEL) control:

 VOLUME (LEVEL) control offers adjustment for the    

   

corresponding input channel, turn clockwise to increase and anti-clockwise    

   

to decrease to reduce the volume.

4) 

MUTE button:

 Each channel input (CH1 thru CH5) may be muted by pressing the  

   

MUTE button. The button features LED illumination when muted.

5) 

Z1 to Z4 Zone Selector buttons:

 Each of the CH1 to CH5 input channels can be  

   

routed to any combination of the four output zones. The zone selector buttons   

   

feature LED illumination, the LED will illuminate if the zone is selected.

6) 

VOLUME (LEVEL) control: 

VOLUME (LEVEL) control offers adjustment for the    

   

corresponding output channel, turn clockwise to increase and anti-clockwise to  

   

decrease to reduce the volume.

7) 

MON button:

 The MA 4060MP and MA 4120MP amplifiers both feature a Monitor  

   

output function for status confirmation purposes. Select the MON button on the  

   

desired channel to activate the Monitor function. The Monitor output features a  

   

Volume (Level) control.

8) 

Output VU Meter:

 Each of the five outputs (Z1 to Z4 and MON) feature LED VU  

   

meter plus CLIP and PROTECTION status indicators. The CLIP LED will illuminate to  

   

indicate when the audio signal is too high, in this instance reduce the VOLUME by  

   

turning the volume control anti-clockwise. The PROTECT LED will illuminate if the  

   

amplifier detects a fault or a problem with the output circuit.

Z2

Z4

TREBL E

+10

MON

7

8

7

8

MUTE

Z1

Z3

LEVEL

CH 2

BASS

-10

-10

+10

ZONE 1

LEVEL

0dB

PROT

CLIP

-5

-10

-15

0

1

2

3

4

5

6

10

0

1

2

3

4

5

6

10

Summary of Contents for MA 4060MP

Page 1: ...Order codes CRAM17 MA 4060MP CRAM18 MA 4120MP 4 Zone Mixer Amplifier series with MP3 FM Tuner User Manual...

Page 2: ...ormative labels from the unit Do not open the equipment and do not modify the unit Do not switch the equipment on and off in short intervals as this will reduce the system s life Only use the equipmen...

Page 3: ...4 16 Line level balanced outputs for each zone output RS232 serial control port for third party system communication Priority input to override other inputs Input priority level from high to low remo...

Page 4: ...23 LINE PHANTOM MIC signal input selector switch 24 Vents 25 Ground lift switch 26 Monitor output port 27 Short circuit priority 28 Telephone signal input port 29 Radio antenna port 30 Zone 1 balanced...

Page 5: ...If the cable runs are unavoidable you should use balanced cables Outputs The high damping factor of your amplifier supplies a clear sound reproduction Unnecessarily long and thin cables used for low...

Page 6: ...ncrease and anti clockwise to decrease to reduce the volume 4 MUTE button Each channel input CH1 thru CH5 may be muted by pressing the MUTE button The button features LED illumination when muted 5 Z1...

Page 7: ...ve the desired mix Care should be taken to when adjusting microphone input volumes and the master volume adjust both of these in small increment s to avoid feedback howl around The goal is to achieve...

Page 8: ...G G G G 100V 100V 100V 100V OUTPUT OUTPUT OUTPUT OUTPUT 70V 70V 70V 70V 4 4 4 4 C OM C OM C OM C OM 240V 50Hz 450W T6 3AL 250V L L R R LINE PHANTOM PHANTOM PHANTOM LINE LINE LINE MIC MIC MIC ZONE TE...

Page 9: ...www cleveracoustics co uk 4 Zone Mixer Amplifier series User Manual 9 Block diagram Z O N E ID 1 2 3 4 R E MO T E MIC...

Page 10: ...rue impedance meter do not standard multimeters Balanced XLR jack connection Jack plug Total impedance 81 MA 4060MP 41 MA 4120MP Total impedance 167 MA 4060MP 83 MA 4120MP WARNING Be sure to attach th...

Page 11: ...s check the sound pressure level with a meter in order to keep to the legal threshold Replacing the fuse Only replace the fuse by a fuse of the same type and rating Before replacing the fuse unplug th...

Page 12: ...revent possible harm to the environment or human health from uncontrolled waste disposal please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of...

Reviews: