Clever Acoustics MA 240Z5 User Manual Download Page 8

Connections To The Mains

Before connecting the amplifier to the local mains voltage outlet should be checked to ensure the 

available supply is 240V~AC 50Hz. This product is CLASS1 and requires a protective mains earth 

to be connected at all times. DO NOT remove or disconnect the earth.

Power On/Off Procedure

After connecting your amplifier to the mains, turn all controls counter clockwise to the “min” 

position. Turn on audio sources (MP3 players, CD players, Microphones etc) before powering the 

amplifier ON. The last product to be switched on is the amplifier.

If you wish to power off the system, turn the amplifier’s master volume control counter clockwise 

to the “min” position before switching the amplifier OFF before any audio sources are switched off. 

By following this procedure it will prevent acoustic shocks to the speakers or potential damage to 

system components. 

Machine operation

1. After connecting all audio sources and powering on the mixer amplifier, adjust the level of each 

audio input to achieve the desired “mix”. Care should be taken to when adjusting microphone 

input volumes and the master volume, adjust both of these in small increment’s to avoid feedback 

(howl around). The goal is to achieve a clear balance between music and voice ensuring  

announcements can be clearly heard.

2. Microphone input No.1 features selectable voice operated override (VOX), this will mute all 

other inputs. After 3 seconds of no signal to the MIC1 input the other inputs will return to their 

original state. The VOX level can be adjusted on the rear panel.

3. The Clever Acoustics amplifiers all feature output VU meter’s with CLIP indication. Should the 

CLIP indicator illuminate (flashing) the output of the amplifier is too high, turn the master volume 

anti-clockwise to reduce the output.

4. The Clever Acoustics amplifiers all feature protection with LED indication. Should the  

PROTECT indicator illuminate, turn the master volume control anti-clockwise fully and switch off 

the amplifier for 15 seconds as the amplifier may have entered PROTECT mode temporarily due 

to a peak signal, care should then be taken to ensure all input levels are set correctly. If the  

amplifier persists to enter PROTECT mode the amplifier should be switched off and left to cool 

for 5-10 minutes before switching back on. If the PROTECT indicator remains lit this indicates a 

problem with the amplifier or amplifier load (ie Short Circuit).

5. Speaker & Amplifier systems can produce high sound pressure levels, please operate all 

controls with caution to ensure people are not exposed to excessive or dangerous sound pressure 

levels.

7

Summary of Contents for MA 240Z5

Page 1: ...USER MANUAL MA 240Z5 100V 240W 5 Zone Mixer Amplifier Order code CRAM10 www cleveracoustics co uk...

Page 2: ...TION TAKE CARE USING THIS EQUIPMENT HIGH VOLTAGE RISK OF ELECTRIC SHOCK Before your initial start up please make sure that there is no damage caused during transportation Should there be any consult y...

Page 3: ...ipment and the power cable periodically If the equipment is dropped or damaged disconnect the mains power supply immediately Have a qualified engineer inspect the equipment before operating again If t...

Page 4: ...The Mixer Amplifier series is equipped with priority function They are designed to suit all PA system application in schools offices and stores Features 5 Zone Mixer amplifier for paging and backgrou...

Page 5: ...z Sensitivity 250mV 47k Tone Control Bass 100Hz Treble 100Hz 12dB S N ratio 65dB Frequency response 80Hz 15kHz Tel input Sensitivity 0 3V 10k S N ratio 65dB Frequency response 100Hz 15kHz 3dB Outputs...

Page 6: ...ume control Use this control to increase or decrease the chime volume 17 Line Mic volume controls Use this control to increase or decrease the line and mic volume 18 Zone 1 5 Speaker outputs Use this...

Page 7: ...e the damping factor and thus the low frequencies in a negative way In order to safeguard good sound quality the damping factor should lie around 50 The longer a cable has to be the thicker it should...

Page 8: ...o achieve a clear balance between music and voice ensuring announcements can be clearly heard 2 Microphone input No 1 features selectable voice operated override VOX this will mute all other inputs Af...

Page 9: ...OFF ON OFF ON OFF ON OFF PRIORITY MIC 1 GAIN CHIME 2 TONE 4 TONE REMOTE MIC 240V 50Hz T6 3AL 250V MIC 2 GAIN 48V PHANTOM MIC 3 GAIN 48V PHANTOM MIC 4 GAIN 48V PHANTOM TEL VOLUME INPUT LINE 1 OUT LINE...

Page 10: ...ure to attach the supplied terminal cover attached after con nection Because high voltage is applied to the speaker terminals car should be taken never touch these terminals to avoid electric shock Al...

Page 11: ...h has to be connected Switch the unit on After switching on the speaker system wait 8 10 seconds before you turn the volume control up in order to avoid speaker damage CAUTION Increase the level of ea...

Page 12: ...have any further questions please contact your dealer CAUTION DANGER TO LIFE DISCONNECT FROM THE MAINS BEFORE STARTING MAINTENANCE OPERATION Problem Chart CAUSE The power cord is not connected The pow...

Page 13: ...the environment or human health from uncontrolled waste disposal please seperate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources House...

Reviews: