9
B.
Keypad Control Panel
Figure 3-10
KEYPAD CONTROL PANEL
1.
Timer Display.
The four-digit display shows minutes and
seconds remaining in the countdown from the
set time (99:99 to 00:00).
2.
Number Keys.
Press the Number Keys to set the minutes and
seconds required. (Pressing 1, 2, 3, 4 sets the
Timer for 12 minutes and 34 seconds.)
3.
Clear Key.
Press the Clear Key to stop the Timer. Press
the Clear Key again for 3 seconds to reset the
Timer to zero (00:00) before setting a new
time.
4.
Start/Stop Key.
The Start/Stop Key starts and stops the Timer.
5.
Reset Indicator Light.
This light is lit when the SteamChef is
overheated. It stays lit and a buzzer sounds
until the steamer is Reset. See “High Limit
Lockout” in Chapter 3.
6.
The Timed/Manual Switch
This switch selects the Timed or Manual
operating mode. Manual mode has a fixed 60-
minute timer. See “Operating and Cooking
Procedure – Manual Mode” in Chapter 5.
Summary of Contents for SteamChef 22CGT3.1