Page
7
Instruction of Fully Pneumatic Filli
ng Machine of SGY
Series
2-2 Operation Method
(1)
Connect the air source and slide the air inlet collar toward the machine.
(2)
Check whether the air pressure meter is in the specified range (roughly reading
in the “12-3 o’clock” range). If not, draw the air pressure knob outwards to unlock,
rotate the pressure regulator until the pressure is in the specified range
(0.40.5Mpa) and push the knob back in to lock.
(3)
Use the Auto/Semiauto switch to set the filler to the desired operation method.
(4)
To make an adjustment, you can loosen the locking handle on the adjustment
sensor, rotate the handwheel, take note of the value on the position display and
fasten the handle.
(5)
Adjust the front valve (for adjusting drawing speed) and behind valve (for
adjusting filling speed) as shown in Figure 1 to get reasonable drawing and filling
speed.
Figure 1 to get reasonable drawing and filling speed.
(6)
Fill the container with product and prepare the container to be filled.
(7)
Proceed with filling and control the operation with the foot pedal. Step on the foot
pedal once to finish each filling operation. You can adjust and use the Automatic
function if you are proficient enough to keep up with the filling speed.
Front valve
rear valve