background image

6

 

SK50503

 

Orifice, Burner, Natural Gas

 

6,8

 

 
 

 
 

(0-2000 Ft. Elev. #52 Drill)

 

 
 

 
 

SK50505

 

Orifice, Burner, Natural Gas

 

6,8

 

 
 

 
 

(2000-4000 Ft. Elev. #1/16 Drill)

 

 
 

 
 

SK50507

 

Orifice, Burner, Natural Gas

 

6,8

 

 
 

 
 

(4000-6000 Ft Elev. #53 Drill)

 

 
 

 
 

SK50504

 

Orifice, Burner, L.P.

 

6,8

 

 
 

 
 

(0-2000 Ft. Elev. #57 Drill)

 

 
 

 
 

SK50506

 

Orifice, Burner, L.P.

 

6,8

 

 
 

 
 

(2000-4000 Ft. Elev. #58 Drill)

 

 
 

 
 

SK50508

 

Orifice, Burner, L.P.

 

6,8

 

 
 

 
 

(4000-6000 Ft. Elev. #59 Drill)

 

 
 

7

 

SK00192

 

Manifold, Burner (SQL SGM-30-X)

 

1

 

 
 

SK00193

 

Manifold, Burner (SGL SGM-40-X)

 

1

 

8

 

KE51111

 

Pilot name Sensor

 

1

 

 
 

 
 

(Thermopile Type) (Manual Ignition)

 

 
 

 
 

KE51159

 

Pilot Flame Sensor

 

1

 

 
 

 
 

(Mercury Vapour Type) (Spark Ignition)

 

 
 

9

 

KE01016

 

Ignition Electrode (Spark Ignition)

 

1

 

10

 

KE51114

 

Pilot Burner

 

1

 

11

 

KE51115

 

Holder, Pilot Flame Sensor

 

1

 

 
 

 
 

(Manual Ignition)

 

 
 

12

 

KE51116

 

Orifice, Pilot, Natural Gas (.020")

 

1

 

 
 

KE51162

 

Orifice, Pilot, L.P. (.0145")

 

1

 

13

 

KE51155

 

Combination Gas Control Valve, Natural

 

1

 

 
 

 
 

Gas, 24 VAC (Spark Ignition)

 

 
 

 
 

KE51163

 

Combination Gas Control Valve, L.P.,

 

1

 

 
 

 
 

24 VAC (Spark Ignition)

 

 
 

 
 

SK50608

 

Combination Gas Control Valve, Natural

 

1

 

 
 

 
 

Gas, 24 VAC (Manual Ignition)

 

 
 

 
 

SE00043

 

Combination Gas Control Valve, L.P.,

 

1

 

 
 

 
 

24 VAC (Manual Ignition)

 

 
 

 
 

KE51110

 

Combination Gas Control Valve, Natural

 

1

 

 
 

 
 

Gas, 120 VAC (Manual Ignition)

 

 
 

 
 

KE51161

 

Combination Gas Control Valve, L.P.,

 

1

 

 
 

 
 

120 VAC (Manual Ignition)

 

 
 

14

 

SK50249

 

Heat Spreader (R.H. End Piece)

 

1

 

 
 

SK50531

 

Heat Spreader (L.H. End Piece)

 

1

 

 
 

SK50532

 

Heat Spreader (with Thermostat cut-out)

 

1

 

 
 

SK50213

 

Heat Spreader (Plain)

 

3,5

 

15

 

SK50416

 

Washer. Spherical

 

28,36

 

16

 

FA21024

 

Nut, 5/16-18

 

28,36

 

 
 
 
 
 
Use only replacement parts which are factory supplied as to preserve the certification of Underwriters Laboratories, 
American Gas Association, Canadian Standards Association or Canadian Gas Association (as applicable).  The use 
of other than factory supplied replacement parts will void the warranty. 
 
 
 
 
 
 
 

Summary of Contents for SGL-X

Page 1: ...Repair Manual Free Standing Gas Skillets Models SGM X SGL X...

Page 2: ...llet On Off Toggle Switch Electrical 7 Components Dwg Controls electrical power to the skillet Timer Control Knob This knob controls the bell timer and allows the Electrical operator to select a time...

Page 3: ...Screw 10 32 x 1 4 2 5 SK50363 Orifice Zip Tube Natural Gas 1 0 2000 Ft Elev 61 Drill SK50669 Orifice Zip Tube Natural Gas 1 2000 4000 Ft Elev 62 Drill SK50671 Orifice Zip Tube Natural Gas 1 4000 6000...

Page 4: ...Pilot L P 0145 1 13 KE51155 Combination Gas Control Valve Natural 1 Gas 24 VAC Spark Ignition KE51163 Combination Gas Control Valve L P 1 24 VAC Spark Ignition SK50608 Combination Gas Control Valve N...

Page 5: ...ELECTRICAL COMPONENTS 4...

Page 6: ...Fuse 1 1 2 Amp Spark Ignition 1 KE51140 Fuse 4 10 Amp Manual Ignition 1 15 SK50680 Switch Rocker Momentary 1 16 SK50728 Capacitor 20 MFD Silver Metal 1 16a Capacitor 30 MFD Silver Metal 1 Please orde...

Page 7: ...lve 1 11 FA19060 Set Screw 8 32 x 1 8 1 12 SK00241 Push Button 1 13 14 KE00508 Hand Wheel 1 14 FA19501 Set Screw 3 8 16 x 3 8 1 15 SK50556 Bushing Hand Wheel 1 16 SK50602 Hydraulic Pump 1 17 FA31009 L...

Page 8: ...8 Sleeve 1 10 SK50666 Roller 1 11 SK50604 Bracket Relief Valve 1 12 SK50628 On Tubing 77 SGL 30 X 1 SK50629 Oil Tubing 88 1 4 SGL 40 X 1 SK50630 On Tubing 86 1 2 SGM 30 X 1 SK50631 Oil Tubing 97 3 4 S...

Page 9: ...HYDRAULIC JACK ASSEMBLY 8...

Page 10: ...Mounting Bracket Hydraulic Jack 1 18 FA31009 Lockwasher 5 16 2 19 FA20010 Hex Nut 5 16 18 2 20 SK50552 Mounting Pin Bottom Jack 1 21 FA10032 Screw 4 40 x 5 8 2 22 FA32002 Tooth Lockwasher 4 2 23 FA32...

Page 11: ...ELECTRIC JACK ASSEMBLY 10...

Page 12: ...Bottom Jack 1 14 FA20010 Hex Nut 5 16 18 2 15 FA31009 Lockwasher 5 16 2 16 SK50542 Bracket Mounting Electric Jack 1 17 FA30078 Washer 2 18 FA10603 Bolt 5 16 18 x 3 4 2 19 SK50644 Spacer L H 3 16 Thick...

Page 13: ...Piece 1 4 20 x 1 2 2 7 KE50122 Spring Hinge 30 Gal 1 KE50121 Spring Hinge 40 Gal 1 8 KE51217 Cylinder Hinge 1 9 KE50824 Bearing Hinge 1 10 SK50209 Washer 1 11 SK00101 Bolt 3 8 16 x 1 1 Use only replac...

Page 14: ...ob 3 4 9 SK00175 Deflector Assy 30 Gal 1 SK00176 Deflector Assy 40 Gal 1 The first figure applies to 30 gal skillets the second figure applies to 40 gal skillets Use only replacement parts which are f...

Page 15: ...3 SE50022 Yoke Connection Kit 1 4 FA00016 0 Ring 1 5 FA95022 Retaining Ring 1 6 KE51736 Spout Nut 1 7 KE50832 3 4 Spout 10 A x 9 B 1 8 KE51401 Single Pantry Control Valve c w Item No 2 1 9 KE51403 Do...

Page 16: ...2 No Correct external power supply problem 2 Is the main power lower pilot light Yes Go to step 6 illuminated No Go to step 3 3 Is the 4 10 amp fuse manual ignition Replace blown fuse 1 1 2 amp fuse s...

Page 17: ...ment Procedure and adjust flame if necessary If adjustment is not required or unsuccessful replace defective pilot flame sensor 17 Yes Go to step 19 Look through peep hole Is a spark being generated N...

Page 18: ...ot Flame Adjustment and Gas Pressure Adjustment Procedure If this does not correct the problem check incoming operating gas supply It should be minimum 7 WC natural gas or 12 WC LP gas If gas pressure...

Page 19: ...units go to step 4 On 208 240V units is either one of the 10 amp fuses blown No Go to step 3 3 Yes Go to step 4 Is there 120 VAC present at output of 208 240 120 VAC transformer No Replace defective...

Page 20: ...W C natural gas and 11 W C LP gas 3 Turn gas pressure adjustment screw under cover screw clockwise to increase or counterclockwise to decrease gas pressure 4 Replace cover screw PILOT FLAME ADJUSTMEN...

Page 21: ...Remove hose from tank and turn jack upside down Push in on the jack s piston rod Oil with air bubbles will seep out the end of the hydraulic hose Continue pushing down on the rod until all air bubbles...

Page 22: ...nto new tank 7 Tilt oil tank up at back so that oil flows toward pump 8 Turn pump shaft counter clockwise until oil starts to seep out of elbow 9 Set pump and oil tank down so that oil tank is sitting...

Page 23: ...n approximately 1 8 in the hole where the first slotted screw was removed from 5 Remove second slotted screw 6 While holding Allen wrench remove pin 7 Turn Allen wrench clockwise to tighten or counter...

Page 24: ...WIRING DIAGRAM SPARK IGNITION 23 WIRING DIAGRAM MANUAL IGNITION...