1 1/2” IPS common drain.
Do not connect other units to
this drain.
Do not use PVC pipe for drain.
Condensate Return Drain Line
100 watts
Right - 3”, Left - 3”, Rear - 3”
(12” on control side if adjoin-
ing wall or equipment is over
30” high for service acess)
Contact factory for
variances to clearances.
NOTES
:
Cleveland Range reserves right of design improvement or modification, as warranted.
Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes.
Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are ASME/N. Bd, UL, NSF and CSA.
ACTUAL CAPACITIES:
Kettle 6 gallons/23 liters or 192, 4 oz. servings.
• Other size servings may be calculated.
Each compartment has capacity for:
• Three, 12˝ x 20˝ x 2
1
⁄
2
˝ or six, 12˝ x 20˝ x 1˝
deep Cafeteria Pans.
WATER QUALITY REQUIREMENT
The recommended minimum water quality stan-
dards whether untreated or pre-treated, based
upon 10 hours of use per day, and a Daily
Blowdown, are as follows:
TOTAL DISSOLVED
SOLIDS
less than 60 parts per million
TOTAL ALKALINITY
less than 20 parts per million
SILICA
less than 13 parts per million
pH FACTOR
greater than 7.5
CHLORINE
less than 30 parts per million
Consult a local water treatment specialist for an on
site water analysis for recommendations concerning
steam generator feed water treatment (if required),
in order to remove or reduce harmful concentrations
of minerals. The use of highly mineralized water will
mean that more frequent servicing of the steam
generator will be necessary. The fact that a water
supply is potable is not proof that it will be suitable
for the generator.