2
descaling agent.
REMEMBER TO MOVE THE YELLOW HANDLE ON THE WATER FILL
VALVE TO ALIGN WITH THE VALVE BODY
. Before applying the descaler, turn on the power
switch to close the drain valve. This will also energize the fill valve.
STEP #3
Using a funnel and tubing, pour the liquid descaler into the generator through the port the safety relief
valve was removed from.
STEP #4
After the descaling agent has been introduced into the generator, replace the safety relief valve.
1.
Place the upper compartment timer switch in the manual position. As the generator is filling
with water, this will allow any air in the top to escape.
2.
To completely fill the generator with water, bypass the water level probe:
a.
Remove the black wire at the terminal marked HI on the water level control board that
connects to the water level probe.
b.
When the water begins to enter the upper cooking compartment, CAREFULLY replace
the black wire on the water level control. This will turn the water off.
STEP #5
DO NOT PRESS THE AMBER STEAM SWITCH. THIS CHEMICAL WORKS BEST WHEN
COLD.
STEP #6
Wait 1-2 hours to allow for descaling of the generator. Drain the generator by turning off the red POWER
switch. The drain and fresh water solenoid valves will open for three minutes allowing the generator to
flush out. After draining, fill the generator with fresh water and repeat the flush process by turning off the
power switch.
STEP #7
After the generator has been rinsed out, remove the hand hole plate and gasket as explained in STEP #1.
Observe the edges and surfaces of the hand hole and the plate for excessive wear-and corrosion. Replace
the used hand hole plate gasket with a new one and install new anodes.
For the anodes to work properly, the hanger must be firmly connected to the support rod. Make sure no
scale or debris is between the support and the hanger. It must be a metal to metal connection.
Do not use a gasket sealing material on the hand hole plate gasket. When tightening the nut on the bar,
make sure that at least 1/16” of gasket material is showing all of the way around the inside of the hand
hole plate.
Reinstall the wire removed from the purge timer in the electric box.