![Clemco Pulsar II Owner'S Manual Download Page 15](http://html.mh-extra.com/html/clemco/pulsar-ii/pulsar-ii_owners-manual_2622428015.webp)
15
(1) Pull the filler strip from the window moulding.
(2) Push the window (from the cabinet inside) through the door opening from the back to remove from the
front.
(3) Install a new window moulding in the window opening. This must be done with the filler strip channel fac-
ing the front of the cabinet.
(4) Install the view window into the slit of the moulding from the front side.
(5) Thread the strip into the installation tool and pull it. At the same time pay attention that the end of the strip
and the end of the moulding are not overlapped.
4.7.7 Back fitting rubber curtain in case of using abrasive blasting media
(
1) Position the rubber curtains to mark the holes in the cabinet wall.
(2) Bore 4,5 mm holes.
(3) Fix the hooks into the holes and hang up rubber curtain.
4.7.8 Back fitting cyclone wear plate in case of using abrasive blast media
(1) Remove cyclone from cabinet.
(2) Remove cyclone inlet plate and pipe.
(3) Angle the wear plate into the cyclone inlet until it is in position with the straight end at the cyclone inlet.
(4) Pry the wear plate against the inner wall of the cyclone by using a board.
(5) Install screws into the previously bored holes to fix the wear plate.
4.7.9 Cartridge Pulsing Timing and Pressure
Pressure
=
5 bar
Pulsing can also be performed at a pressure > 5 bar, but this results in more wear.