Clemco Apollo 60 HP Instruction Manual Download Page 10

APOLLO 60 HP SUPPLIED-AIR RESPIRATOR

Page 9

6.2

Helmet Suspension Adjustment and Replacement,

Figure 3

! WARNING

The suspension maintains a fixed distance be-
tween the head and the helmet. It is critical that
the suspension is properly installed, and ad-
justed as described, to provide maximum head
protection and comfort.

6.2.1

Remove the cape from the helmet per Section 9.4.

6.2.2

Remove and discard the old suspension and

suspension strap by extracting the plastic tabs from the
wedge-shaped clefts in the shell.

6.2.3

Unfasten the vinyl sweatband from the two lower,

outside buttons (A and B in Figure 3).

6.2.4

The suspension fits head sizes 6.5 to 8. Head

sizes are marked on the headband slots. Slide the headband
tongue through the front holder until the desired head size
is reached. It is important that the adjustment be made
evenly on both sides. Press the selected slots firmly onto
the lugs on the front band.

6.2.5

Fasten the vinyl sweatband onto the buttons of the

suspension.

6.2.6

Install the suspension strap before installing the

suspension. Insert the yellow end tabs into the clefts on the
helmet shell. When correctly installed, the strap is between
the suspension and helmet shell and above the ears.

6.2.7

Install the suspension by inserting the four white

plastic tabs into the clefts on the shell. The tabs must fully
seat in their respective locators.

6.2.8

Try the helmet on for fit and readjust if necessary.

6.2.9

Check that the chin strap is in place, then reattach

the cape onto the helmet following the instructions in
Section 9.4.

7.0

MAINTENANCE PROGRAM

7.1

Basic Service

7.1.1

A program for maintenance and care of the respi-

rator must be established based on application, working
conditions, and hazards involved, and include the follow-
ing basic service.

• Inspection for defects (including a leak check)
• Cleaning and disinfecting
• Repair (service maintenance)
• Storage

Equipment must be properly maintained to retain its origi-
nal effectiveness. [Reference OSHA Regulations 1910.134
(f)].

7.2

Inspection

7.2.1

Inspect respirators before and after each use.

Inspection shall include a check for tightness of connec-
tions and the condition of the lenses, suspension, cape
and elastic parts, breathing tube, respirator hoses and
connectors, Constant-Flow Connector or alternate air con-
trol valve or temperature control valve. [Reference OSHA
Regulations 1910.134 (f)(2)].

7.2.2

The respirator hoses, breathing tube, air entry

ports, and fittings must be checked for dust contamination,
and cleaned before making connections.

7.2.3

The helmet suspension is a very important com-

ponent for maintaining maximum hard hat and respiratory
protection. It must be inspected for fit and wear on a daily
basis, and replaced immediately at the first sign of wear.
(See Section 6.2)

Figure 3.

White Plastic Tabs

(rear)

Button B

Suspension Strap

Button A

White Plastic

Tabs

(front)

Head Band

Tongue

Front Holder

Vinyl

Sweatband

Headband

Size Slots

Front Band

Lugs

Summary of Contents for Apollo 60 HP

Page 1: ...ou are using a Clemco Distributor Parts and Maintenance Guide refer to the orange warnings insert preceding the Index before continuing with the following instructions CLEMCO INDUSTRIES CORP One Cable...

Page 2: ...i rator 1 1 2 OSHA requires the employer to establish a com prehensive respiratory protection program per regulations 29 CFR 1910 134 a b and 29 CFR 1926 103 to include the following 1 Program coordin...

Page 3: ...sup plied air respirator equipment by blasting opera tors and all personnel within the work site area Leadpoisoningcancausedeath OSHAhasstated that the permissible exposure limit of lead is 50 microgr...

Page 4: ...ntenance manuals for information on use and maintenance of these respirators 1 5 Special Use Limitations 1 5 1 Air pressure at the point of attachment the point of attachment is where the respirator s...

Page 5: ...s conditions Constant Flow Connector CFC Provides non adjust able volume of supplied air within the cfm range required by OSHA Air Control Valve ACV Enables the user to a d j u s t the volume of suppl...

Page 6: ...r lens by the window frame are up to five perforated outer lenses 3 2 2 Check that the inner lens is in place See Section 9 1 3 2 3 The perforated outer lenses are secured to the helmet by the window...

Page 7: ...necessary safety and monitoring devices plus suitable in line air filters and purifying equipment to assure breathing air quality Refer ence OSHA Regulations 29 CFR 1910 134 d and 29 CFR 1926 103 f 4...

Page 8: ...attached If the regulator is adjusted with static pressure no air flow pressure may drop below the required pressure when the respirator is connected and may result in low air flow Setting the pressur...

Page 9: ...e positioned and maintained without any interference from items such as hair facial hair or shirt collars between the collar and user s neck 5 9 Pull the cape down to fully extend it and connect the f...

Page 10: ...Try the helmet on for fit and readjust if necessary 6 2 9 Check that the chin strap is in place then reattach the cape onto the helmet following the instructions in Section 9 4 7 0 MAINTENANCE PROGRAM...

Page 11: ...to circulate to dry condensation from the cape and from inside the helmet 7 5 2 Long term storage 7 5 2 1 After inspection cleaning and thorough drying and after necessary repairs are made the cape s...

Page 12: ...eplacing Perforated Outer Lenses Figure 4 9 2 1 Up to five outer lenses can be installed at one time For maximum visibility install only enough lenses to last during a work period 9 2 2 Preparing lens...

Page 13: ...tructions 9 6 Window Frame 9 6 1 The window frame must be replaced when it becomes difficult to maintain a seal or to keep the latch closed When replacing the window frame the acoustical foam inside t...

Page 14: ...includes items 6 and 7 04398 6 Adaptor 3 8 hose to 3 8 pipe 00022 7 Union 3 8 hose to 3 8 hose 01020 8 Disconnect 1 4 female 00025 9 Adaptor 3 8 hose to 1 4 pipe 01019 10 Acoustical foam kit sides 04...

Reviews: