EN
OPERATION
16
Tennant T5 (06--06)
DRAINING SOLUTION TANK
1. To drain remaining water from the solution tank,
pull the solution tank level hose off the hose fitting
(Figure 37).
FIG. 37
2. To rinse out the solution tank remove the clean--out
cap at the rear of the machine and spray water
directly into the clean-out ports (Figure 38).
FIG. 38
3. Clean the solution tank filter (Figure 39).
FIG. 39
CHARGING BATTERIES
ATTENTION: To prolong the life of the batteries
only recharge the batteries if the machine was
used for a total of 30 minutes or more. Do not leave
batteries discharged for lengthy periods.
WARNING: Fire Or Explosion Hazard.
Batteries Emit Hydrogen Gas. Keep Sparks And
Open Flame Away. Keep Battery Compartment
Open When Charging.
FOR SAFETY: When servicing batteries, wear
protective gloves and eye protection when
handling batteries and battery cables. Avoid
contact with battery acid.
BATTERY CHARGER SPECIFICATIONS:
S
CHARGER TYPE:
-- FOR SEALED (Gel) BATTERIES
-- FOR WET (Lead acid) BATTERIES
S
OUTPUT VOLTAGE - 24 VOLTS
S
OUTPUT CURRENT - 20 AMPS
S
AUTOMATIC SHUTOFF CIRCUIT
S
FOR DEEP CYCLE BATTERY CHARGING
ON--BOARD BATTERY CHARGER SETTINGS:
If your machine is equipped with the on--board charger,
the charger settings must be set for your battery type,
Wet/lead acid or sealed/Gel, before charging. Failure to
properly set will result in battery damage.
To determine your battery type, see battery label.
Contact your battery supplier if not specified.
To verify what the charger is currently for, connect the
charger cord into an electrical receptacle. The charger
will display a sequence of codes. One of the codes will
either read “GEL” or “Acd” (Figure 40).
GEL = Set for sealed/maintenance free batteries
Acd = Set for wet/lead acid batteries
FIG. 40