background image

EN

OPERATION

16

Tennant T5 (06--06)

DRAINING SOLUTION TANK

1. To drain remaining water from the solution tank,

pull the solution tank level hose off the hose fitting

(Figure 37).

FIG. 37

2. To rinse out the solution tank remove the clean--out

cap at the rear of the machine and spray water

directly into the clean-out ports (Figure 38).

FIG. 38

3. Clean the solution tank filter (Figure 39).

FIG. 39

CHARGING BATTERIES

ATTENTION: To prolong the life of the batteries

only recharge the batteries if the machine was

used for a total of 30 minutes or more. Do not leave

batteries discharged for lengthy periods.

WARNING: Fire Or Explosion Hazard.

Batteries Emit Hydrogen Gas. Keep Sparks And

Open Flame Away. Keep Battery Compartment

Open When Charging.

FOR SAFETY: When servicing batteries, wear

protective gloves and eye protection when

handling batteries and battery cables. Avoid

contact with battery acid.

BATTERY CHARGER SPECIFICATIONS:

S

CHARGER TYPE:

-- FOR SEALED (Gel) BATTERIES

-- FOR WET (Lead acid) BATTERIES

S

OUTPUT VOLTAGE - 24 VOLTS

S

OUTPUT CURRENT - 20 AMPS

S

AUTOMATIC SHUTOFF CIRCUIT

S

FOR DEEP CYCLE BATTERY CHARGING

ON--BOARD BATTERY CHARGER SETTINGS:

If your machine is equipped with the on--board charger,

the charger settings must be set for your battery type,

Wet/lead acid or sealed/Gel, before charging. Failure to

properly set will result in battery damage.
To determine your battery type, see battery label.

Contact your battery supplier if not specified.
To verify what the charger is currently for, connect the

charger cord into an electrical receptacle. The charger

will display a sequence of codes. One of the codes will

either read “GEL” or “Acd” (Figure 40).
GEL = Set for sealed/maintenance free batteries

Acd = Set for wet/lead acid batteries

FIG. 40

Summary of Contents for TENNANT T5

Page 1: ...T5 SCRUBBER DRYER OPERATOR MANUAL Clemas Co Unit 5 Ashchurch Business Centre Alexandra Way Tewkesbury Gloucestershire GL20 8NB Tel 01684 850777 Fax 01684 850707 Email info clemas co uk Web www clemas...

Page 2: ...R METER 14 OFF AISLE WAND OPERATION 14 DRAINING AND CLEANING TANKS 15 DRAINING RECOVERY TANK 15 DRAINING SOLUTION TANK 16 CHARGING BATTERIES 16 BATTERY CHARGER SPECIFICATIONS 16 ON BOARD BATTERY CHARG...

Page 3: ...Damaged Power Supply Cord Do Not Modify Plug If the charger supply cord is damaged or broken it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to a...

Page 4: ...TY LABELS The safety labels appear on the machine in the locations indicated Replace labels if they are missing or become damaged or illegible SPINNING BRUSH LABEL Located on scrub head WARNING Spinni...

Page 5: ...8 Solution Tank Level Drain Hose 9 Squeegee Vacuum hose 10 Wall Rollers 11 Squeegee Assembly 12 Solution Tank Clean Out Port 13 Recovery Tank Support Stand 14 Control Board 15 Bucket Fill Port Clean...

Page 6: ...tton 4 Brush pressure decrease button 5 Solution flow increase button 6 Solution flow decrease button 7 Fault indicator Contact Service 8 Supervisor Control indicator Lockout feature 9 Battery charge...

Page 7: ...Hazard Batteries Emit Hydrogen Gas Keep Sparks And Open Flame Away Keep Battery Hood Open When Charging FOR SAFETY When installing batteries wear protective gloves and eye protection Avoid contact wit...

Page 8: ...ilage This brush works well for maintaining concrete wood and grouted tile floors Soft Nylon Bristle Scrub Brush White Recommended for cleaning coated floors without removing finish Cleans without scu...

Page 9: ...e key 2 Attach the pad to the pad driver before installing the driver Secure pad with centerlock Figure 9 FIG 9 3 Align the pad driver under the motor hub and push it upward to engage Figure 10 FIG 10...

Page 10: ...the supply hose is not in use connect the storage plug to prevent the FaST system from drying out and clogging up the hose Figure 16 FIG 16 FILLING SOLUTION TANK Using a hose or bucket fill the soluti...

Page 11: ...Scrubbing FaST model Ensure that all conventional cleaning agents are drained and rinsed from solution tank STARTING THE MACHINE 1 Release the parking brake if equipped Figure 18 2 Turn the key to th...

Page 12: ...ton clockwise and restart the key to regain power FIG 25 WHILE OPERATING MACHINE WARNING Fire Or Explosion Hazard Do Not Pick Up Flammable Materials Or Reactive Metals 1 Overlap each scrub path by 5 c...

Page 13: ...will get an additional minute of scrubbing FIG 26 HOUR METER The hour meter records the number of total hours the vacuum and brush motors have been powered on Use the hour meter to determine when to...

Page 14: ...trigger for five seconds to relieve the water pressure before disconnecting the solution hose WARNING Fire or Explosion Hazard Do Not Pick Up Flammable Materials Or Reactive Metals DRAINING AND CLEAN...

Page 15: ...es wear protective gloves and eye protection when handling batteries and battery cables Avoid contact with battery acid BATTERY CHARGER SPECIFICATIONS S CHARGER TYPE FOR SEALED Gel BATTERIES FOR WET L...

Page 16: ...IG 42 5 Connect the charger s AC power supply cord into a properly grounded receptacle Figure 43 NOTE The machine will not operate when charging FIG 43 6 The charger will display a sequence of codes o...

Page 17: ...hort circuit Contact Service Center USING AN OFF BOARD BATTERY CHARGER OPTION 1 Transport the machine to a well ventilated area 2 Park the machine on a flat dry surface Turn the key off and set the pa...

Page 18: ...Figure 48 Lock Nut FIG 48 CYLINDRICAL BRUSH MODEL After installing a new set of cylindrical brushes check the brush pattern to ensure proper brush adjustment Brushes that are not properly adjusted wil...

Page 19: ...scrub head or counter clockwise to lower the front Figure 52 FIG 52 3 Recheck brush pattern NOTE Replace brushes when worn to 15mm To Adjust a Tapered Brush Pattern Tools required 10mm wrench and 6mm...

Page 20: ...Before Servicing Machine DAILY MAINTENANCE After Every Use 1 Drain the recovery tank Figure 56 FIG 56 2 Rinse and clean out the recovery tank Figure 57 FIG 57 3 Remove the recovery tank float shut off...

Page 21: ...cylindrical brush scrub head including the idler plates and drive hubs Figure 65 Cylindrical Brush Model FIG 65 11 Wipe the squeegee blades clean Figure 66 Store the squeegee assembly in the raised p...

Page 22: ...17 Recharge the batteries Figure 71 To prolong the life of the batteries only recharge the batteries if the machine was used for a total of 30 minutes or more FIG 71 MONTHLY MAINTENANCE 1 Check the cy...

Page 23: ...Charging 2 Clean the batteries to prevent battery corrosion Use a scrub brush with a mixture of baking soda and water Figure 76 FOR SAFETY When cleaning batteries wear protective gloves and eye protec...

Page 24: ...Transaxle Motor 750 Vacuum Motor Disk Brush Motors Cylindrical Brush Motors 1000 WARNING Electrical Hazard Disconnect Battery Cables Before Servicing Machine FaST SYSTEM MAINTENANCE Every 1000 hours...

Page 25: ...ach wheel to prevent the machine from rolling 5 Secure with tie down straps as shown Figure 85 It may be necessary to install tie down brackets to trailer or truck FOR SAFETY When loading unloading ma...

Page 26: ...Service Center Faulty control handle bail switch Contact Service Center Faulty brush motor or wiring Contact Service Center Worn carbon brushes Contact Service Center Broken or loose belt cylindrical...

Page 27: ...n time Batteries not fully charged Fully recharge batteries Defective batteries Replace battery Batteries need maintenance See BATTERY MAINTENANCE Faulty battery charger Repair or replace battery char...

Page 28: ...teep inclines or contact service center Restart key to reset Lights 1 and 3 blink Scrub head movement is obstructed or actuator motor malfunction Check scrub head for obstruction or con tact service c...

Page 29: ...18 36 54 kg SOLUTION FLOW RATE Low 1 70 L min 1 90 L min 1 70 L min 1 90 L min SOLUTION FLOW RATE Med 1 30 L min 1 51 L min 1 30 L min 1 51 L min SOLUTION FLOW RATE Max 95 L min 1 14 L min 95 L min 1...

Page 30: ...0 m2 h 1950 m2 h 2440 m2 h SOLUTION PUMP 24 Volt DC 3 5 A 5 6 L min open flow 4 13 Bar bypass setting SOLUTION FLOW RATE 0 57 L min 0 83 L min 0 57 L min 0 83 L min CONCENTRATE FLOW RATE 0 57 CC min 0...

Reviews: