![Clemas & Co CS70 90B Operator'S Manual Download Page 27](http://html1.mh-extra.com/html/clemas-and-co/cs70-90b/cs70-90b_operators-manual_2622305027.webp)
MAINTENANCE
UBF 28 NEW
Rev. 00
27/04/09
Pag. 30/36
5. MAINTENANCE
5.1. MAINTENANCE
PROGRAM
A periodical maintenance is very important.
Please write down in the format you find below all the interventions done on the machine.
•
Trained personnel only can service the machine and especially electric and electromechanical
parts by means of suitable tools and equipments.
•
Make reference to FIORENTINI S.r.l. only for service and spare parts.
OPERATION
INTERVENTION
HOW OFTEN
Clean the recovery tank
•
Do not use corrosive substances
Daily
Cleaning
¾
Check the suction pipes
Weekly
¾
Check the rubber suction blades of the
central brush room
¾
Check the battery water level
Every 15 days
¾
Check the suction engine
Every month
¾
Check and register the breaking system
Every 3 months
¾
Check the connection of the battery cables
Every 6 months
¾
Check the brushes of each motor
Every year
Check up
¾
Check the safety devices
¾
Check the electric system
Every year
5.2 BATTERIES MAINTENANCE (BATTERY VERSION MACHINE)
The operator has to check the batteries charge when the machine is on duty by means of the indicator on the
dashboard, which shows:
¾
Green light: charged battery
¾
Yellow light: slightly charged battery
¾
Red light: uncharged battery
The operator must keep the battery room open during the batteries recharge. Moreover:
¾
It is forbidden to use flames and/or to smoke near the batteries;
¾
Pay attention to the battery acid;
¾
Do not develop sparks near the batteries;
¾
Pay attention to the batteries gazes, which can burst;
¾
Do not invert battery polarities.